- Page 9 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
1 GENERAL 
 
 
1.5 Components 
 
1.5.1 General 
 
 
 
Comply with IEC 60950-1 or relevant component 
standard  
(see appended table 1.5.1) 
P
 
1.5.2 
Evaluation and testing of components 
Certified components are 
used in accordance with their 
ratings, certifications and they 
comply with applicable parts 
of this standard. 
Components not certified are 
used in accordance with their 
ratings and they comply with 
applicable parts of IEC 60950 
and the relevant component 
standard. 
Components, for which no 
relevant IEC-standard exists, 
have been tested under the 
conditions occurring in the 
equipment, using applicable 
parts of IEC 60950.
 
P
 
1.5.3 Thermal 
controls 
No thermal controls.
 
1.5.4 Transformers 
Class III equipment to be 
supplied by a separately 
approved power supply with 
an SELV output. Power 
supply not evaluated. Refer to 
Summary of testing. 
1.5.5 Interconnecting 
cables 
The interconnecting cables 
contain only SELV.
 
1.5.6 
Capacitors bridging insulation  
Class III equipment .No 
bridging capacitors. 
1.5.7 
Resistors bridging insulation 
No such components bridging 
double or reinforced 
insulation.
 
1.5.7.1 
Resistors bridging functional, basic or 
supplementary insulation 
 
1.5.7.2 
Resistors bridging double or reinforced insulation 
between a.c. mains and other circuits 
 
1.5.7.3 
Resistors bridging double or reinforced insulation 
between a.c. mains and antenna or coaxial cable  
 
1.5.8 
Components in equipment for IT power systems 
Class III equipment.
 
1.5.9 Surge 
suppressors 
 
 
 
- Page 10 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
1.5.9.1 General 
 
1.5.9.2 
Protection of VDRs 
No VDRs. 
1.5.9.3 
Bridging of functional insulation by a VDR 
 
1.5.9.4 
Bridging of basic insulation by a VDR 
 
1.5.9.5 
Bridging of supplementary, double or reinforced 
insulation by a VDR 
 
 
1.6 Power 
interface 
 
1.6.1 
AC power distribution systems 
Class III equipment.
 
N
 
1.6.2 Input 
current 
(see appended table 1.6.2)  
P
 
1.6.3 
Voltage limit of hand-held equipment 
Class III equipment.
 
N
 
1.6.4 
Neutral conductor  
Class III equipment.
 
N
 
 
1.7 
Marking and instructions 
 
1.7.1 
Power rating  
Marking not required, 
however the marking is 
located on the outside surface 
of the equipment.
 
P
 
 
Rated voltage(s) or voltage range(s) (V)  .............. :
24 Vdc
 
P
 
 
Symbol for nature of supply, for d.c. only .............. :
IEC 60417-1,symbol 
No.5031, is used.
 
P
 
 
Rated frequency or rated frequency range (Hz) ... :
DC rated
 
N
 
 Rated 
current 
(mA or A)  ....................................... :
2.3 A
 
P
 
 
Manufacturer’s name or trade-mark or identification 
mark ...................................................................... :
 
P
 
 Model 
identification 
or type reference .................. :
JBL on stage 400 ID 
P
 
 
Symbol for Class II equipment only  ...................... :
Class III equipment. 
N
 
 Other 
markings and symbols ................................ :
The additional marking does 
not give rise to 
misunderstandings. 
P
 
1.7.2 
Safety instructions and marking 
Provided with marking 
regarding use of specified 
power supply (Not required), 
refer to Copy of marking 
plate. 
P
 
1.7.2.1 General 
Considered P
 
1.7.2.2 Disconnect 
devices 
Class III equipment. 
1.7.2.3 
Overcurrent protective device 
 
1.7.2.4 
IT power distribution systems 
 
 
 
- Page 11 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
1.7.2.5 
Operator access with a tool 
 
1.2.7.6 Ozone 
The equipment does not 
produce Ozone. 
1.7.3 
Short duty cycles 
The equipment is intended for 
continuous operation.
 
1.7.4 Supply 
voltage adjustment .................................. : 
No voltage selector.
 
 
Methods and means of adjustment; reference to 
installation instructions ........................................ : 
 
1.7.5 Power 
outlets 
on the equipment .......................... : 
No standard power outlet.
 
1.7.6 
Fuse identification (marking, special fusing 
characteristics, cross-reference) ......................... : 
No fuses 
1.7.7 Wiring 
terminals 
Class III equipment.
 
1.7.7.1 Protective 
earthing and bonding terminals  .......... : 
 
1.7.7.2 
Terminals for a.c. mains supply conductors  
 
1.7.7.3 
Terminals for d.c. mains supply conductors 
 
1.7.8 
Controls and indicators 
Refer below. 
 
1.7.8.1 Identification, 
location and marking ..................... : 
No controls or figures 
affecting safety provided. 
1.7.8.2 Colours   ............................................................... : 
For functional indication a 
LED lights when the 
equipment is operating. 
1.7.8.3 Symbols 
according to IEC 60417 .........................: 
A stand-by condition is 
indicated by the symbol 
according to IEC 60417-5009.
1.7.8.4 Markings 
using figures  ........................................: 
 N 
1.7.9 
Isolation of multiple power sources .....................: 
Class III equipment.
 
1.7.10 
Thermostats and other regulating devices  ..........: 
Class III equipment.
 
1.7.11 Durability 
The marking withstands 
required tests. 
1.7.12 Removable 
parts 
No removable parts. 
1.7.13 Replaceable 
batteries ..........................................: 
No battery in the equipment. 
 Language(s) .........................................................: 
 
⎯ 
1.7.14 
Equipment for restricted access locations............: 
Equipment not intended for 
installation in RAL. 
 
PROTECTION FROM HAZARDS 
 
2.1 
Protection from electric shock and energy hazards 
P
 
2.1.1 
Protection in operator access areas  
Refer below: 
⎯ 
2.1.1.1 
Access to energized parts 
Class III equipment.
 
 
 
- Page 12 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
 
Test by inspection ................................................. :
 
⎯ 
 
Test with test finger (Figure 2A)  ........................... :
 
⎯ 
 
Test with test pin (Figure 2B) ................................ :
 
⎯ 
 
Test with test probe (Figure 2C)  ........................... :
 
⎯ 
2.1.1.2 
Battery compartments  
No TNV circuits in the 
equipment. 
2.1.1.3 
Access to ELV wiring 
No internal wiring at ELV.
 
 
Working voltage (Vpeak or Vrms); minimum 
distance through insulation (mm) 
 
⎯ 
2.1.1.4 
Access to hazardous voltage circuit wiring 
Class III equipment.
 
2.1.1.5 Energy hazards ..................................................... :
Class III equipment.
 
2.1.1.6 Manual 
controls 
No shafts or konbs. 
2.1.1.7 
Discharge of capacitors in equipment 
Class III equipment.
 
 
Measured voltage (V); time-constant (s) ............... :
 
⎯ 
2.1.1.8 
Energy hazards – d.c. mains supply 
Class III equipment, supplied 
from SELV.
 
 
a) Capacitor connected to the d.c. mains supply  . :
 
⎯ 
 
 
⎯ 
2.1.1.9 Audio 
amplifiers .................................................... :
Considered.  Also refer to 
Summary of Testing. 
2.1.2 
Protection in service access areas 
Class III equipment
 
2.1.3 
Protection in restricted access locations 
Equipment not intended for 
installation in RAL. 
 
2.2 SELV 
circuits 
 
2.2.1 General 
requirements 
Class III equipment. 
SELV limits are not exceeded 
under normal condition and 
after a single fault.  
2.2.2 
Voltages under normal conditions (V)  .................. :
Within SELV limits.
 
2.2.3 
Voltages under fault conditions (V)  ...................... :
Within SELV limits.
 
2.2.4 
Connection of SELV circuits to other circuits  ......: 
SELV circuits are only 
connected to other SELV 
circuits. 
 
2.3 TNV 
circuits 
 
2.3.1 Limits 
No TNV circuits. 
 
Type of TNV circuits .............................................. :
 
⎯ 
Page of 87