JBL ON STAGE 400P (serv.man4) EMC - CB Certificate ▷ View online
- Page 33 of 53 -
Report
No.
100711
TRF No. IECEN60950_1C
U
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
INSULATION (see 2.10.5.4)
N
See separate test report
⎯
V
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)
N
V.1 Introduction
N
V.2
TN power distribution systems
N
W
ANNEX W, SUMMATION OF TOUCH CURRENTS
N
W.1
Touch current from electronic circuits
N
W.1.1 Floating
circuits
N
W.1.2 Earthed
circuits
N
W.2
Interconnection of several equipments
N
W.2.1 Isolation
N
W.2.2
Common return, isolated from earth
N
W.2.3
Common return, connected to protective earth
N
X
ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause
C.1)
C.1)
N
X.1
Determination of maximum input current
N
X.2
Overload test procedure
N
Y
ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3)
N
Y.1 Test
apparatus ..................................................... :
N
Y.2
Mounting of test samples ..................................... :
N
Y.3 Carbon-arc
light-exposure apparatus .................. :
N
Y.4
Xenon-arc light exposure apparatus .................... :
N
Z
ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2)
N
AA
ANNEX AA, MANDREL TEST (see 2.10.5.8)
N
BB
ANNEX BB, CHANGES IN THE SECOND EDITION
⎯
- Page 34 of 53 -
Report
No.
100711
TRF No. IECEN60950_1C
EN 60950-1:2006 – CENELEC COMMON MODIFICATIONS
Contents
Add the following annexes:
Annex ZA (normative)
Annex ZA (normative)
Normative references to international publications
Special national conditions
Annex ZC (informative) A-deviations
P
General
Delete all the “country” notes in the reference document according to the following
list:
1.4.8
list:
1.4.8
Note 2
1.5.1
Note 2 & 3
1.5.7.1
Note
1.5.8
Note 2
1.5.9.4
Note
1.7.2.1
Note 4, 5 & 6
2.2.3
Note
2.2.4
Note
2.3.2
Note
2.3.2.1 Note 2
2.3.4
Note 2
2.6.3.3
Note 2 & 3
2.7.1
Note
2.10.3.2 Note 2
2.10.5.13 Note 3
3.2.1.1 Note
3.2.4
Note 3.
2.5.1
Note 2
4.3.6
Note 1 & 2
4.7
Note 4
4.7.2.2
Note
4.7.3.1 Note 2
5.1.7.1
Note 3 & 4
5.3.7
Note 1
6
Note 2 & 5
6.1.2.1
Note 2
6.1.2.2
Note
6.2.2
Note 6.
2.2.1
Note 2
6.2.2.2
Note
7.1
Note 3
7.2
Note
7.3
Note 1 & 2
G.2.1 Note 2
Annex H Note 2
⎯
1.3.Z1
Add the following subclause:
1.3.Z1 Exposure to excessive sound pressure
The apparatus shall be so designed and constructed as to present no danger when
used for its intended purpose, either in normal operating conditions or under fault
conditions, particularly providing protection against exposure to excessive sound
pressures from headphones or earphones.
1.3.Z1 Exposure to excessive sound pressure
The apparatus shall be so designed and constructed as to present no danger when
used for its intended purpose, either in normal operating conditions or under fault
conditions, particularly providing protection against exposure to excessive sound
pressures from headphones or earphones.
NOTE Z1 A new method of measurement is described in EN 50332-1, Sound system
equipment:
Headphones and earphones associated with portable audio equipment - Maximum sound
pressure level measurement methodology and limit considerations - Part 1: General method
for “one package equipment”, and in EN 50332-2, Sound system equipment: Headphones
and earphones associated with portable audio equipment - Maximum sound pressure level
measurement methodology and limit considerations - Part 2: Guidelines to associate sets
with headphones coming from different manufacturers.
equipment:
Headphones and earphones associated with portable audio equipment - Maximum sound
pressure level measurement methodology and limit considerations - Part 1: General method
for “one package equipment”, and in EN 50332-2, Sound system equipment: Headphones
and earphones associated with portable audio equipment - Maximum sound pressure level
measurement methodology and limit considerations - Part 2: Guidelines to associate sets
with headphones coming from different manufacturers.
N
1.5.1
Add the following NOTE:
NOTE Z1 The use of certain substances in electrical and electronic equipment is restricted
within the EU: see Directive 2002/95/EC
within the EU: see Directive 2002/95/EC
N
1.7.2.1
Add the following NOTE:
NOTE Z1 In addition, the instructions shall include, as far as applicable, a warning that
excessive sound pressure from earphones and headphones can cause hearing loss
excessive sound pressure from earphones and headphones can cause hearing loss
N
- Page 35 of 53 -
Report
No.
100711
TRF No. IECEN60950_1C
2.7.1
Replace the subclause as follows:
Basic requirements
To protect against excessive current, short-circuits and earth faults in PRIMARY
CIRCUITS, protective devices shall be included either as integral parts of the
equipment or as parts of the building installation, subject to the following, a), b) and
c):
a) except as detailed in b) and c), protective devices necessary to comply with the
requirements of 5.3 shall be included as parts of the equipment;
b) for components in series with the mains input to the equipment such as the
supply cord, appliance coupler, r.f.i. filter and switch, short-circuit and earth fault
protection may be provided by protective devices in the building installation;
c) it is permitted for PLUGGABLE EQUIPMENT TYPE B or PERMANENTLY
CONNECTED EQUIPMENT, to rely on dedicated overcurrent and short-circuit
protection in the building installation, provided that the means of protection, e.g.
fuses or circuit breakers, is fully specified in the installation instructions.
If reliance is placed on protection in the building installation, the installation
instructions shall so state, except that for PLUGGABLE EQUIPMENT TYPE A the
building installation shall be regarded as providing protection in accordance with
the rating of the wall socket outlet.
Basic requirements
To protect against excessive current, short-circuits and earth faults in PRIMARY
CIRCUITS, protective devices shall be included either as integral parts of the
equipment or as parts of the building installation, subject to the following, a), b) and
c):
a) except as detailed in b) and c), protective devices necessary to comply with the
requirements of 5.3 shall be included as parts of the equipment;
b) for components in series with the mains input to the equipment such as the
supply cord, appliance coupler, r.f.i. filter and switch, short-circuit and earth fault
protection may be provided by protective devices in the building installation;
c) it is permitted for PLUGGABLE EQUIPMENT TYPE B or PERMANENTLY
CONNECTED EQUIPMENT, to rely on dedicated overcurrent and short-circuit
protection in the building installation, provided that the means of protection, e.g.
fuses or circuit breakers, is fully specified in the installation instructions.
If reliance is placed on protection in the building installation, the installation
instructions shall so state, except that for PLUGGABLE EQUIPMENT TYPE A the
building installation shall be regarded as providing protection in accordance with
the rating of the wall socket outlet.
N
2.7.2
This subclause has been declared ‘void’.
⎯
3.2.3
Delete the NOTE in Table 3A, and delete also in this table the conduit sizes in
parentheses.
parentheses.
⎯
3.2.5.1
Replace
“60245 IEC 53” by “H05 RR-F”;
“60227 IEC 52” by “H03 VV-F or H03 VVH2-F”;
“60227 IEC 53” by “H05 VV-F or H05 VVH2-F2”.
In Table 3B, replace the first four lines by the following:
| Up to and including 6
| Up to and including 6
|
0,75
a)
|
| Over 6 up to and including 10 |
(0,75)
b)
1,0
|
| Over 10 up to and including 16 |
(1,0)
c)
1,5
|
In the conditions applicable to Table 3B delete the words “in some countries” in
condition
condition
a)
.
In NOTE 1, applicable to Table 3B, delete the second sentence.
N
3.3.4
In Table 3D, delete the fourth line: conductor sizes for 10 to 13 A, and replace with
the following:
| Over 10 up to and including 16 |
the following:
| Over 10 up to and including 16 |
1,5 to 2,5
|
1,5 to 4
|
Delete the fifth line: conductor sizes for 13 to 16 A.
N
4.3.13.6
Add the following NOTE:
NOTE Z1 Attention is drawn to 1999/519/EC: Council Recommendation on the limitation of
exposure of the general public to electromagnetic fields 0 Hz to 300 GHz. Standards taking
into account this Recommendation which demonstrate compliance with the applicable EU
Directive are indicated in the OJEC.
exposure of the general public to electromagnetic fields 0 Hz to 300 GHz. Standards taking
into account this Recommendation which demonstrate compliance with the applicable EU
Directive are indicated in the OJEC.
⎯
- Page 36 of 53 -
Report
No.
100711
TRF No. IECEN60950_1C
Annex H
Replace the last paragraph of this annex by:
At any point 10 cm from the surface of the OPERATOR ACCESS AREA, the dose
rate shall not exceed 1 μSv/h (0,1 mR/h) (see NOTE). Account is taken of the
background level.
Replace the notes as follows:
At any point 10 cm from the surface of the OPERATOR ACCESS AREA, the dose
rate shall not exceed 1 μSv/h (0,1 mR/h) (see NOTE). Account is taken of the
background level.
Replace the notes as follows:
NOTE These values appear in Directive 96/29/Euratom.
Delete NOTE 2.
N
Biblio-
graphy
graphy
Additional EN standards.
⎯
ZA
NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR
CORRESPONDING EUROPEAN PUBLICATIONS
CORRESPONDING EUROPEAN PUBLICATIONS
⎯
ZB
SPECIAL NATIONAL CONDITIONS
⎯
1.2.4.1
In Denmark, certain types of Class I appliances (see 3.2.1.1) may be provided with
a plug not establishing earthing conditions when inserted into Danish socket-
outlets.
a plug not establishing earthing conditions when inserted into Danish socket-
outlets.
N
1.5.7.1
In Finland, Norway and Sweden, resistors bridging BASIC INSULATION in
CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements
in 1.5.7.2.
CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements
in 1.5.7.2.
N
1.5.8
In Norway, due to the IT power system used (see annex V, Figure V.7), capacitors
are required to be rated for the applicable line-to-line voltage (230 V).
are required to be rated for the applicable line-to-line voltage (230 V).
N
1.5.9.4
In Finland, Norway and Sweden, the third dashed sentence is applicable only to
equipment as defined in 6.1.2.2 of this annex.
equipment as defined in 6.1.2.2 of this annex.
N
1.7.2.1
In Finland, Norway and Sweden, CLASS I PLUGGABLE EQUIPMENT TYPE A
intended for connection to other equipment or a network shall, if safety relies on
connection to protective earth or if surge suppressors are connected between the
network terminals and accessible parts, have a marking stating that the equipment
must be connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall be as follows:
In Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun
pistorasiaan"
In Norway: “Apparatet må tilkoples jordet stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat uttag”
intended for connection to other equipment or a network shall, if safety relies on
connection to protective earth or if surge suppressors are connected between the
network terminals and accessible parts, have a marking stating that the equipment
must be connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall be as follows:
In Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun
pistorasiaan"
In Norway: “Apparatet må tilkoples jordet stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat uttag”
N
1.7.5
In Denmark, socket-outlets for providing power to other equipment shall be in
accordance with the Heavy Current Regulations, Section 107-2-D1, Standard
Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used on Class I equipment. For
STATIONARY EQUIPMENT the socket-outlet shall be in accordance with Standard
Sheet DK 1-1b or DK 1-5a.
accordance with the Heavy Current Regulations, Section 107-2-D1, Standard
Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used on Class I equipment. For
STATIONARY EQUIPMENT the socket-outlet shall be in accordance with Standard
Sheet DK 1-1b or DK 1-5a.
N
2.2.4
In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex.
N
2.3.2
In Finland, Norway and Sweden there are additional requirements for the
insulation. See 6.1.2.1 and 6.1.2.2 of this annex.
insulation. See 6.1.2.1 and 6.1.2.2 of this annex.
N
Click on the first or last page to see other ON STAGE 400P (serv.man4) service manuals if exist.