DOWNLOAD JBL ON STAGE 400P (serv.man4) Service Manual ↓ Size: 729.93 KB | Pages: 87 in PDF or view online for FREE

Model
ON STAGE 400P (serv.man4)
Pages
87
Size
729.93 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-stage-400p-sm4.pdf
Date

JBL ON STAGE 400P (serv.man4) EMC - CB Certificate ▷ View online

 
 
- Page 49 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
Tmra=40
°C.  Temperature limits of winding include less 10°C for thermocouple measurement method.  If 
no limit is stated, temperature is for reference only.  The product operate in normal condition, refer to 
Summary of testing. 
* Apparatus was tesed with supply voltage to the external adaptor with 90Vac and 264Vac seperately; and 
the supply voltage to the speaker is 24Vdc from the adaptor output. 
Temperature T of winding: 
t
1
 (°C)
R
1
 (
Ω)
t
2
 (°C)
R
2
 (
Ω)
T (
°C) 
Allowed 
T
max
 (
°C)
Insulatio
n class
 
 
 
 
 
 
 
 
Supplementary information: 
 
4.5.5 
TABLE: Ball pressure test of thermoplastic parts 
 Allowed 
impression 
diameter (mm) .....................:
≤ 2 mm 
⎯ 
Part 
Test temperature 
(
°C) 
Impression diameter 
(mm) 
 
 
 
 
 
 
Supplementary information: 
 
 
4.7 
TABLE: Resistance to fire 
Part 
Manufacturer of 
material 
Type of material 
Thickness 
(mm) 
Flammability
class 
Evidence 
 
 
 
 
 
 
 
 
 
 
 
 
Supplementary information: 
 
 
 
- Page 50 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
 
5.1 
TABLE: touch current measurement 
 
Measured between: 
Measured  
(mA) 
Limit  
(mA) 
Comments/conditions 
 
 
 
 
 
 
 
 
Supplementary information: 
 
 
5.2 
TABLE: Electric strength tests, impulse tests and voltage surge tests 
Test voltage applied between: 
Voltage shape 
(AC, DC, 
impulse, surge) 
Test voltage 
(V) 
Breakdow
 Yes / No
Functional: 
 
 
 
 
 
 
 
 
Basic/supplementary: 
 
 
 
 
 
 
 
 
Reinforced: 
 
 
 
 
 
 
 
 
Supplementary information: 
 
 
 
 
- Page 51 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
 
5.3 
TABLE: Fault condition tests 
P
 
 
Ambient temperature (
°C) ...................................: 
25 
⎯ 
 
Power source for EUT: Manufacturer, model/type, 
output rating .........................................................: 
Harman multimedia 
on stage 400 ID 
24 Vdc, 2.3 A 
⎯ 
Component  
No. 
Fault 
Supply 
voltage
 (V) 
Test 
time 
Fuse #
Fuse 
current
(A) 
Observation 
⎯ 
Blocked opening 
24Vdc
1.0 h 
⎯ 
Input 
current:
0.83A
 
No hazard. No significant rise in 
temperatures. 
Speaker Overload 
(max 
undistorted 
sound level 
with 100Hz and 
1kHz) 
24Vdc
4.0 h 
⎯ 
Input 
current:
1.2A
 
No hazard. No significant rise in 
temperatures. 
+5V dc 
output (Ipod 
charging 
connector) 
s-c 24Vdc
2.0 
⎯ 
Input 
current:
1.1A 
Normal operation. No hazard. No 
significant rise in temperatures. 
Subwoofer 
speaker 
s-c 24Vdc
0.5 
⎯ 
Input 
current:
0.6A 
Normal operation. No hazard. No 
significant rise in temperatures. 
Speakers   s-c 
24Vdc
0.5 h 
⎯ 
Input 
current:
0.5A 
Normal operation. No hazard. No 
significant rise in temperatures. 
Supplementary information:  
 
 
 
- Page 52 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
C.2 TABLE: 
transformers 
 
Loc. 
Tested insulation 
Working 
voltage 
peak / V 
 
(2.10.2) 
Working 
voltage 
rms / V 
 
(2.10.2) 
Required 
electric 
strength 
 
(5.2) 
Required 
clearance / 
mm 
 
(2.10.3) 
Required 
creepage 
distance / 
mm 
(2.10.4) 
Required 
distance 
thr. insul. 
 
(2.10.5) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Loc. 
 
 
 
 
Tested insulation 
 
 
Test 
voltage/ 
Measured 
clearance / 
mm 
Measured 
creepage 
dist./ mm 
Measured 
distance 
thr. insul. / 
mm; 
number of 
layers 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Supplementary information: 
* 2 or 3 layers / 0.4mm / Annex U
 
Page of 87
Display