DOWNLOAD JBL ON STAGE 400P (serv.man4) Service Manual ↓ Size: 729.93 KB | Pages: 87 in PDF or view online for FREE

Model
ON STAGE 400P (serv.man4)
Pages
87
Size
729.93 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-stage-400p-sm4.pdf
Date

JBL ON STAGE 400P (serv.man4) EMC - CB Certificate ▷ View online

 
 
- Page 45 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
2.10.3 and 
2.10.4 
TABLE: Clearance and creepage distance measurements 
Clearance (cl) and creepage 
distance (cr) at/of/between: 
U peak 
(V) 
U r.m.s.
 (V) 
Required cl
 (mm) 
cl 
 (mm) 
Required cr 
(mm) 
cr 
(mm) 
Functional: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Basic/supplementary: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Reinforced: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Supplementary information: 
 
 
2.10.5 
TABLE: Distance through insulation measurements 
Distance through insulation (DTI) at/of: 
U peak
(V) 
U rms 
(V) 
Test 
voltage 
 (V) 
Required DTI
 (mm) 
DTI 
(mm) 
 
 
 
 
 
 
 
 
 
 
 
 
Supplementary information: 
 
 
 
 
- Page 46 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
 
4.3.8 TABLE: 
Batteries 
 
Battery category .......................................... :
1) Lithium 
2) NiMh 
3) NiCad 
4) Lithium Ion 
Manufacturer ............................................... :
 
Type / model................................................ :
 
Voltage ........................................................ :
Capacity ...................................................... :
mAh 
Tested and Certified by (incl. Ref. No.)....... :
 
 
Circuit protection diagram: 
 
 
 
 
 
 
 
 
 
 
MARKINGS AND INSTRUCTIONS (1.7.12, 1.7.15) 
Location of replaceable battery 
1) In operator access areas 
2) In service access areas 
 Language(s): 
Close to the battery 
 
In the servicing instructions 
 
In the operating instructions 
 
 
 
- Page 47 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
 
4.3.8 TABLE: 
Batteries 
The tests of 4.3.8 are applicable only when appropriate battery 
data is not available 
 
 
Is it possible to install the battery in a reverse polarity position? 
 
 
Non-rechargeable batteries 
Rechargeable batteries 
Discharging 
Charging 
Discharging 
Reversed 
charging 
 
Meas. 
current
Manuf. 
Specs. 
Un-
intentional 
charging 
Meas. 
current
Manuf. 
Specs.
Meas. 
current 
Manuf. 
Specs. 
Meas. 
current
Manuf. 
Specs.
Max. 
current 
during 
normal 
condition 
 
 
 
 
 
 
 
 
 
Max. 
current 
during 
fault 
condition 
 
 
 
 
 
 
 
 
 
 
Test results: 
 
Verdict
- Chemical leaks 
 
 
- Explosion of the battery 
 
 
- Emission of flame or expulsion of molten metal 
 
 
- Electric strength tests of equipment after completion of tests 
 
 
Supplementary information: 
 
 
 
 
- Page 48 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
4.5 
TABLE: Thermal requirements 
 Supply 
voltage (V)  ..........................:
90 Vac 
264 Vac 
⎯ 
Maximum measured temperature T of part/at:: 
T (
°C) 
Allowed 
T
max
 
(
°C) 
Speaker 
C44 surface 
49.6 
48.4 
105 
SW1 44.6 
43.7 
-- 
R2  
106.3 
93.8 
-- 
Enclousure  
45.6 
44.4 
95 
PCB near U1 
51.5 
50.3 
105 
Heat sink 
54.8 
53.5 
-- 
Winding of L1 
49.1 
47.5 
100 
Output cord 
54.6 
53.4 
105 
C23  
52.3 
51.1 
105 
Ambient 40.0 
40.0 
-- 
Adapter 
Optocoupler(U2) 59.2 
66.3 
100 
C9 55.9 
60.7 
105 
Winding of L4 
53.2 
56.9 
120 
C7/C8 57.6 
62.0 
105 
CY2 55.6 
57.3 
125 
CY1 62.3 
67.3 
125 
C2 58.0 
63.0 
105 
Winding of L1 
63.1 
64.2 
120 
ZD1 50.0 
52.3 
130 
Appliance inlet  
51.3 
51.4 
70 
PCB (under BD1) 
59.5 
63.3 
130 
Output cord 
47.1 
48.8 
105 
CX1 (near CY2)) 
66.4 
60.1 
100 
NTC1 (near CX1) 
57.3 
59.7 
100 
PCB (near D3) 
66.2 
64.7 
130 
Winding of T1 
68.0 
75.2 
-- 
Core of T1 
65.0 
71.7 
105 
Enclosure 48.0 
51.5 
95 
Supplementary information: 
Page of 87
Display