JBL ON STAGE 400P (serv.man4) EMC - CB Certificate ▷ View online
- Page 45 of 53 -
Report
No.
100711
TRF No. IECEN60950_1C
2.10.3 and
2.10.4
2.10.4
TABLE: Clearance and creepage distance measurements
N
Clearance (cl) and creepage
distance (cr) at/of/between:
distance (cr) at/of/between:
U peak
(V)
U r.m.s.
(V)
Required cl
(mm)
cl
(mm)
Required cr
(mm)
cr
(mm)
Functional:
Basic/supplementary:
Reinforced:
Supplementary information:
2.10.5
TABLE: Distance through insulation measurements
N
Distance through insulation (DTI) at/of:
U peak
(V)
U rms
(V)
Test
voltage
(V)
Required DTI
(mm)
DTI
(mm)
Supplementary information:
- Page 46 of 53 -
Report
No.
100711
TRF No. IECEN60950_1C
4.3.8 TABLE:
Batteries
N
Battery category .......................................... :
1) Lithium
2) NiMh
3) NiCad
4) Lithium Ion
2) NiMh
3) NiCad
4) Lithium Ion
Manufacturer ............................................... :
Type / model................................................ :
Voltage ........................................................ :
V
Capacity ...................................................... :
mAh
Tested and Certified by (incl. Ref. No.)....... :
Circuit protection diagram:
MARKINGS AND INSTRUCTIONS (1.7.12, 1.7.15)
Location of replaceable battery
1) In operator access areas
2) In service access areas
2) In service access areas
Language(s):
Close to the battery
In the servicing instructions
In the operating instructions
- Page 47 of 53 -
Report
No.
100711
TRF No. IECEN60950_1C
4.3.8 TABLE:
Batteries
N
The tests of 4.3.8 are applicable only when appropriate battery
data is not available
data is not available
⎯
Is it possible to install the battery in a reverse polarity position?
⎯
Non-rechargeable batteries
Rechargeable batteries
Discharging
Charging
Discharging
Reversed
charging
Meas.
current
Manuf.
Specs.
Specs.
Un-
intentional
charging
Meas.
current
Manuf.
Specs.
Specs.
Meas.
current
Manuf.
Specs.
Specs.
Meas.
current
Manuf.
Specs.
Specs.
Max.
current
during
normal
condition
current
during
normal
condition
Max.
current
during
fault
condition
current
during
fault
condition
Test results:
Verdict
- Chemical leaks
- Explosion of the battery
- Emission of flame or expulsion of molten metal
- Electric strength tests of equipment after completion of tests
Supplementary information:
- Page 48 of 53 -
Report
No.
100711
TRF No. IECEN60950_1C
4.5
TABLE: Thermal requirements
P
Supply
voltage (V) ..........................:
90 Vac
264 Vac
⎯
Maximum measured temperature T of part/at::
T (
°C)
Allowed
T
max
(
°C)
Speaker
C44 surface
49.6
48.4
105
SW1 44.6
43.7
--
R2
106.3
93.8
--
Enclousure
45.6
44.4
95
PCB near U1
51.5
50.3
105
Heat sink
54.8
53.5
--
Winding of L1
49.1
47.5
100
Output cord
54.6
53.4
105
C23
52.3
51.1
105
Ambient 40.0
40.0
--
Adapter
Optocoupler(U2) 59.2
66.3
100
C9 55.9
60.7
105
Winding of L4
53.2
56.9
120
C7/C8 57.6
62.0
105
CY2 55.6
57.3
125
CY1 62.3
67.3
125
C2 58.0
63.0
105
Winding of L1
63.1
64.2
120
ZD1 50.0
52.3
130
Appliance inlet
51.3
51.4
70
PCB (under BD1)
59.5
63.3
130
Output cord
47.1
48.8
105
CX1 (near CY2))
66.4
60.1
100
NTC1 (near CX1)
57.3
59.7
100
PCB (near D3)
66.2
64.7
130
Winding of T1
68.0
75.2
--
Core of T1
65.0
71.7
105
Enclosure 48.0
51.5
95
Supplementary information:
Click on the first or last page to see other ON STAGE 400P (serv.man4) service manuals if exist.