JBL ON STAGE 400P (serv.man4) EMC - CB Certificate ▷ View online
Test Report issued under the responsibility of
www.nemko.com
This Test Report , when bearing the Nemko name and logo is only valid when issued by a Nemko
laboratory, or by a laboratory having special agreement with Nemko.
laboratory, or by a laboratory having special agreement with Nemko.
TEST REPORT
IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006
Information technology equipment – Safety –
Part 1: General requirements
Report Reference No
. ....................:
100711
Date of issue ....................................:
26 March 2008
Total number of pages ......................
Refer to page 6
CB/CCA Testing Laboratory Name
:
Nemko Hong Kong Ltd.
Phone:
(+852) 2675 0288
Address ...........................................:
Unit 3-5, 1/F, Festigood Centre, 8 Lok Yip Road, On Lok
Tsuen,Fanling, N.T., Hong Kong
Tsuen,Fanling, N.T., Hong Kong
Applicant’s name
............................:
Harman Multimedia
Address ............................................:
Manufacturer’s name
.....................:
Harman Multimedia
Address ............................................:
Same as above
Factory’s name
...............................:
Harman JBL(Suzhou) Ltd.
Address ............................................:
3, Jinshan Road, Suzhou New District, Jiangsu Province, 215011,
China
China
Test specification:
Standard...........................................:
IEC 60950-1:2005 (2nd Edition) and
EN 60950-1:2006
Test procedure .................................:
CB
Non-standard test method…………..:
N/A
Test Report Form No
. ....................:
IECEN60950_1C
Test Report Form(s) Originator....................... :
SGS Fimko Ltd (Nemko)
Master TRF..................................................... :
Dated 2007-06 (2008 02)
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme
procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended
to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
If this Test Report Form is used by non-CCA members, the CIG logo and the reference to the CCA Procedure shall be
removed.
This report is not valid as a CCA Test Report unless signed by an approved CCA Testing Laboratory and
appended to a CCA Test Certificate issued by an NCB in accordance with CCA
procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended
to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
If this Test Report Form is used by non-CCA members, the CIG logo and the reference to the CCA Procedure shall be
removed.
This report is not valid as a CCA Test Report unless signed by an approved CCA Testing Laboratory and
appended to a CCA Test Certificate issued by an NCB in accordance with CCA
- Page 2 of 53 -
Report
No.
100711
TRF No. IECEN60950_1C
Test item description .....................:
Computer Speaker system
Trade Mark .......................................:
Manufacturer ....................................:
Harman Multimedia
Model/Type reference ......................:
JBL on stage 400 ID
Ratings .............................................:
2.3 A, 24 Vdc
Name and address of production-sites (Factories):
Harman JBL (Suzhou) LTD.
3, Jinshan Road, Suzhou New District, Jiangsu Province, 215011, China
3, Jinshan Road, Suzhou New District, Jiangsu Province, 215011, China
- Page 3 of 53 -
Report
No.
100711
TRF No. IECEN60950_1C
Testing procedure and testing location:
CB/CCA Testing Laboratory:
Nemko Hong Kong Ltd.
Testing location/ address ...................... :
Unit 3-5, 1/F, Festigood Centre, 8 Lok Yip Road, On Lok
Tsuen,Fanling, N.T., Hong Kong
Tsuen,Fanling, N.T., Hong Kong
Associated CB Laboratory:
Testing location/ address ...................... :
Tested by (name + signature)..... :
Pat Leung
Approved by (+ signature)........... :
Sam-Geun Gwack
Testing procedure: TMP
Tested by (name + signature)..... :
Approved by (+ signature)............ :
Testing location/ address ...................... :
Testing procedure: WMT
Tested by (name + signature)..... :
Witnessed by (+ signature) .......... :
Approved by (+ signature)........... :
Testing location/ address ...................... :
Testing procedure: SMT
Tested by (name + signature)..... :
Approved by (+ signature)............ :
Supervised by (+ signature) ........ :
Testing location/ address ................:
Testing procedure: RMT
Tested by (name + signature)..... :
Approved by (+ signature)............ :
Supervised by (+ signature) ........ :
Testing location/ address ...................... :
- Page 4 of 53 -
Report
No.
100711
TRF No. IECEN60950_1C
Summary of testing:
Tested according to national requirements
for the following countries:
for the following countries:
All CENELEC members as listed in EN 60950-1:2006.
All CB members as listed in CB Bulletin 112A, December
2006.
At the time of issuing this report only limited countries are
listed for IEC60950-1: 2005, therefore in addition, country
deviations for IEC60950 3rd and IEC60950-1:2001 edition
are included.
List from IEC 60950-1: 2001 edition:
Australian differences: CB Bulletin No.112A, Dec 2006.
Canadian differences: CB Bulletin No.112A, Dec 2006.
US differences: CB Bulletin No.112A, Dec 2006.
Singapore differences: CB Bulletin No.112A, Dec 2006.
Korean differences: CB Bulletin No.112A, Dec 2006.
Israeli differences: (not related to CB Bulletin No.112A,
December 2006).
Japanese differences: CB Bulletin No.112A, Dec 2006.
Chinese differences: CB Bulletin No.112A, Dec 2006.
All CB members as listed in CB Bulletin 112A, December
2006.
At the time of issuing this report only limited countries are
listed for IEC60950-1: 2005, therefore in addition, country
deviations for IEC60950 3rd and IEC60950-1:2001 edition
are included.
List from IEC 60950-1: 2001 edition:
Australian differences: CB Bulletin No.112A, Dec 2006.
Canadian differences: CB Bulletin No.112A, Dec 2006.
US differences: CB Bulletin No.112A, Dec 2006.
Singapore differences: CB Bulletin No.112A, Dec 2006.
Korean differences: CB Bulletin No.112A, Dec 2006.
Israeli differences: (not related to CB Bulletin No.112A,
December 2006).
Japanese differences: CB Bulletin No.112A, Dec 2006.
Chinese differences: CB Bulletin No.112A, Dec 2006.
General:
Normal load as described in Annex L or as
close as possible to the most severe
normal use.
Normal load as described in Annex L or as
close as possible to the most severe
normal use.
Normal operation is considered 1/8th of maximum
undistorted power. Non-clipping was determined using a 1
KHz sinusoidal signal input. For maximum normal operation,
1/8th of the non-clipping amplitude was used with a filtered
pink noise input signal.
undistorted power. Non-clipping was determined using a 1
KHz sinusoidal signal input. For maximum normal operation,
1/8th of the non-clipping amplitude was used with a filtered
pink noise input signal.
1.5, 2.5. 3.2 External Power Supply
The external power supply was not evaluated as part of this
report. An external power supply approved to IEC 60950 shall
be provided. The external power supply The external power
supply output shall be separately certified as limited power
source, complying with the national regulations of the
countries in which the appliance is to be sold.
report. An external power supply approved to IEC 60950 shall
be provided. The external power supply The external power
supply output shall be separately certified as limited power
source, complying with the national regulations of the
countries in which the appliance is to be sold.
1.7.2 Safety instructions, required markings
regarding use of a specified power supply
regarding use of a specified power supply
Class III Equipment with an enclosure made of V-2 material,
using a non-special connector for the DC input must have a
marking stating the manufacturer and model number of the
power supply to be used. Marking is provided.
using a non-special connector for the DC input must have a
marking stating the manufacturer and model number of the
power supply to be used. Marking is provided.
1.7.12 Language of safety
markings/instruction
markings/instruction
Instructions and equipment marking related to safety
shall be applied in a language, which is acceptable in the
country in which the equipment is to be sold.
shall be applied in a language, which is acceptable in the
country in which the equipment is to be sold.