Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 9 of 46 
 
3.4  Climatic conditions  
 
parameter 
admissible range 
actual range 
 
Ambient temperature 
15 °C - 35 °C 
20°C -23°C 
O.K. 
Relative humidity 
30 % - 60 % 
51 % 
O.K. 
Atmospheric pressure 
86-106kPa 
100.1kPa O.K. 
 
3.5  Testing location   
Shenzhen Academy of Metrology and Quality Inspection (SMQ) Guangdong EMC Compliance 
Testin Center. 
 –ELA 502  
Bldg. of Shenzhen Academy of Metrology and Quality Inspection , Longzhu Road, Nanshan District, 
Shenzhen, China. 
 
All tests have been supervised by a Nemko engineer.  
 
Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 10 of 46 
 
Measurement of conducted emission 
4.1 Standards 
Generic standard 
  
Product or product family standard 
EN 55022:2006 
Limit class 
Class B 
Basic standard 
CISPR 16 
Date of testing  
2008.2.27 
4.2 Measurement equipment 
 
Equipment 
Last Calibration 
Type 
 
Serial No
Manufacturer 
EMI Test Receiver 
January 25, 2008 ESCS30 
SB2603 
Rohde & Schwarz  
AMN 
January 25, 2008 ESH2-Z5 
SB3321 
Rohde & Schwarz  
Limiter 
January 30, 2008 ESH3-Z2 
SB3319/01 
Rohde & Schwarz  
4.3 Test set-up 
The test set-up was realized in a shielded chamber according to the above-mentioned standard. If 
more details are necessary, e.g. because of wiring or auxiliary equipment, annex B with a photo or a 
rough figure of the test set-up is attached. 
 
The test has been performed as following: 
1)  Preview test; Peak- and Average-Detector; measuring time 1 ms; 
frequency step 4 kHz; all lines; 
2)  Find frequencies with maximum emission: 
Acceptance-analysis: Limit minus 10dB 
Peak-reduction:10Peaks frequency range 150 kHz - 30 MHz 
3)  Final test; Quasi-Peak and Average-Detector; measuring time 1 s; 
at frequencies from step 2).
 IF Bandwidth: 9kHz
 
4)  If there are more than 10 peaks within the 10 dB margin a manual test with all settings is 
necessary to find the maximum readings. 
The EUT was placed on the top of an insulating table 0.8 meters above the ground at a shielded 
room. The EUT was placed 0.4 meters from the conducting wall of shielded room with EUT being 
connected to the power mains through a line impedance stabilization network (LISN). The LISN 
provide 50Ohm/50μH of coupling impedance for the measuring instrument. Both lines of the power 
mains connected to the EUT were checked for maximum conducted interference. The frequency 
range from 150kHz to 30MHz was searched.  The worst-case emissions are reported. 
Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 11 of 46 
4.4 Test result 
Power ports 
AC input 
Mode 
Diagram and Table  Remarks 
Result 
 TM 1 
Diagram
  001  
Table
 005 
Line  L   
 
Pass 
 TM 1 
Diagram
  002  
Table
 005 
Line  N 
 
Pass 
 TM 2 
Diagram
  003 
Table
 005 
Line  L  
 
Pass 
 TM 2 
Diagram
  004 
Table
 005 
Line  N 
 
Pass 
Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 12 of 46 
4.5  Diagrams and tables 
4.5.1 Diagram 001 
Conducted Disturbance
EUT:           
M/N:JBL200D
Op Cond:       
Connect to PC
Test Spec:     
L
Comment:       
AC 230V/50Hz
   0
  10
  20
  30
  40
  50
  60
dBuV
  70
0.15
MHz
30
1
10
ConQP
ConAV
Mkr  :    5.83000MHz   34.4 dBuV
 
 
 
 
 
Page of 46
Display