DOWNLOAD JBL ON STAGE 200ID (serv.man3) Service Manual ↓ Size: 2.47 MB | Pages: 46 in PDF or view online for FREE

Model
ON STAGE 200ID (serv.man3)
Pages
46
Size
2.47 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-stage-200id-sm3.pdf
Date

JBL ON STAGE 200ID (serv.man3) EMC - CB Certificate ▷ View online

Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 5 of 46 
1 Summary 
Emission 
1.1 Standards 
Generic standard 
-- 
Product or product family standard 
EN 55022:2006 
Product category 
-- 
1.2 Results 
Environmental 
phenomena 
Port / Test module 
 
Basic standard and test 
setup 
Limit class 
Result 
Conducted emission 
Input AC power ports    
CISPR 16 / CISPR 22 
 Table 1 – 
Class B  
Pass 
Radiated emission 
Enclosure 
  
CISPR 16 / CISPR 22 
 Table 5 (3m) – 
Class B 
Pass 
Harmonic current 
emission 
AC input power ports   
EN 61000-3-2:2006 
Class A 
Pass* 
 
Voltage fluctuations 
and flicker 
AC input power ports   
 
EN 61000-3-
3:1995+A1:2001+A2:2005 
See section 7 
Pass ** 
For details see test modules 
 
 
*) 
For devices with a rated power of 50 W or less, not being lighting equipment, no limit values are effective.
(EN61000-3-2) 
For professionally used devices with a total rated power exceeding 1 kW no limit values are effective. 
(EN61000-3-2) 
 
**) 
There is no testing required if the device does not generate any significant voltage fluctuations or flicker. 
(EN61000-3-3) 
A short time measurement confirmed the assumption that this is the fact. The details in the test module 
are representing the results of the short time measurement. 
 
 
 
 
 
Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 6 of 46 
2 Summary 
Immunity 
2.1 Standards 
Generic standard 
-- 
Product or product family standard 
EN55024:1998+A1:2001+A2:2003 
Product category: 
--  
Performance criteria: 
see table below 
2.2 Results 
Environmental 
phenomena 
Port / Test module 
Basic standard and test setup 
Performance criteria 
Result 
Electrostatic 
discharge, ESD 
Enclosure 
EN 61000-4-2:1995/A1:
1998/A2:2001 
B Pass 
Radiated immunity 
Enclosure 
80 - 1000 MHz 
EN 61000-4-3:2006 
A Pass 
Electrical Fast 
Transients/Bursts 
Immunity 
Input AC power ports  EN 61000-4-4:2004 
B Pass 
Surge Immunity 
Input AC power ports  EN 61000-4-5:2006 
B Pass 
Conducted Immunity 
Input AC power ports   EN 61000-4-6:1996/A1:2001 
A Pass 
Voltage dips and 
interruptions 
Immunity 
Input AC power ports  EN 61000-4-11:2004 
B for 0% 0.5 
C for 0% 250 
C for 70% 25 
Pass 
Remark:EUT not contain components susceptible to magnetic fields,so N/A for Power-frequency 
magnetic field test . 
For details see test modules 
 
Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 7 of 46 
2.3  Performance criteria according to product or product family standards 
 
Performance criterion A 
The equipment shall continue to operate as intended without operator intervention. No degradation 
of performance or loss of function is allowed below a performance level specified by the 
manufacturer when the equipment is used as intended. The performance level may be replaced by a 
permissible loss of performance. If the minimum performance level or the permissible performance 
loss is not specified by the manufacturer, then either of these may be derived from the product 
description and documentation, and by what the user may reasonably expect from the equipment if 
used as intended. 
 
Performance criterion B 
After the test, the equipment shall continue to operate as intended without operator intervention. No 
degradation of performance or loss of function is allowed, after the application of the phenomena 
below a performance level specified by the manufacturer, when the equipment is used as intended. 
The performance level may be replaced by a permissible loss of performance. During the test, 
degradation of performance is allowed. However, no change of operating state or stored data is 
allowed to persist after the test. If the minimum performance level (or the permissible performance 
loss) is not specified by the manufacturer, then either of these may be derived from the product 
description and documentation, and by what the user may reasonably expect from the equipment if 
used as intended. 
 
Performance criterion C
 
Loss of function is allowed, provided the function is self-recoverable, or can be restored by the 
operation of the controls by the user in accordance with the manufacturer’s instructions. Functions, 
and/or information stored in non-volatile memory, or protected by a battery backup, shall not be lost.
 
 
 
 
 
 
 
 
 
 
 
Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 8 of 46 
3 General 
information 
3.1  Description of Equipment under test (EUT) 
Type of equipment 
Table top 
Floor standing 
Combination 
 
 
 
 
The equipment under test (EUT) is a Computer Speaker system. 
And  model name is on stage 200 ID. 
The input spec of the EUT: 100-240Vac  50/60Hz 0.5A (12 VDC, 1.25 A is output of the adapter 
for the Speaker). 
For technical data see table 1 in annex A. 
3.2  Measurement Uncertainly  
Radiated Emission Test : 30MHz-1000MHz     4.5dB 
                                                1GHz-18GHz           4.6dB 
Conducted Emission Test :
 9KHz-30MHz         3.5dB     
3.3  Test Mode (TM) 
TM 1) 
230V AC 50Hz power source was 
used during the test.  
Connect to PC 
TM 2) 
230V AC 50Hz power source was 
used during the test.  
Connect to Ipod 
Main Auxiliary Equipments list as below 
 
Equipment 
Type 
 
Serial No
Manufacturer 
PC P9111A 
#AB2  CN31104346 
Compact 
LCD monitor 
P4825 
CN3087 
Compact 
Adapter of LCD  
PA-1400-02 
-- 
Liteon 
Keyboard KB-0133 
01669394 
Compact 
mouse M-S69 
-- Compact 
printer BJC-265SP 
EVX81604 
Canon 
Adapter of printer 
AD-300 
-- 
Canon 
modem 56000BPS 
200060057 
Kpt 
Adapter of modem 
AM-1280AV 
-- 
Kpt 
IPOD A1136 
8K63899YZ9M 
APPLE 
 
Page of 46
Display

Click on the first or last page to see other ON STAGE 200ID (serv.man3) service manuals if exist.