JBL ON STAGE 200ID (serv.man3) EMC - CB Certificate ▷ View online
Ident. Nr.:
98323
Date:
2008-3-11
98323__EMC_TRF
page 33 of 46
9.5 Table
9.5.1 Table 013
Frequency Range
(MHz)
80-1000MHz
Field Strength
(V/m)
3V/m 1kHz 80%AM
Steps
(%)
1%
Dwell time
0.5 s
Polarization
Horizontal
Vertical
Front Pass
Pass
Rear Pass
Pass
Left Pass
Pass
Right Pass
Pass
Ident. Nr.:
98323
Date:
2008-3-11
98323__EMC_TRF
page 34 of 46
10 Electrical
Fast
Transients/Bursts Immunity
10.1 Standard
Basic standard
EN 61000-4-4:2004
Date of testing
2008.2.25
Performance criteria:
B
10.2 Measurement equipment
Equipment
Last Calibration
Type
Serial No
.
Manufacturer
EFT simulator
February 25,
2008
2008
NSG2025-1 SB2556 SCHNAFFNER
10.3 Test set-up
See annex B
The EUT is placed on a table that is 0.8meter height. A ground reference plane is placed on the table,
and uses a 0.1m insulation between the EUT and ground reference plane.
The minimum area of the ground reference plane is 1m*1m, and projected beyond the EUT by at least
0.1m on all sides.
Test on power supply ports:
The duration time of each test sequential was 1 minute.
The length of the signal and power lines between the coupling device and the EUT is 0.5m.
The EUT is placed on a table that is 0.8meter height. A ground reference plane is placed on the table,
and uses a 0.1m insulation between the EUT and ground reference plane.
The minimum area of the ground reference plane is 1m*1m, and projected beyond the EUT by at least
0.1m on all sides.
Test on power supply ports:
The duration time of each test sequential was 1 minute.
The length of the signal and power lines between the coupling device and the EUT is 0.5m.
10.4 Test results
Mode
Table
Remarks
Result
TM1;
TM2
014
±
1KV
Tr/Th: 5/50ns
Repetition frequency:5kHz
Test to input a.c. power port
(Signal port cable is less than 3m)
Pass
10.5 Table
10.5.1 Table 014
Injected Line
Voltage
(kV)
Duration time
(s)
Injected Method
Result
+1 60
Direct
Pass
L
-1 60
Direct
Pass
+1 60
Direct
Pass
N
-1 60
Direct
Pass
+1 60
Direct
Pass
L,N
-1 60
Direct
Pass
Ident. Nr.:
98323
Date:
2008-3-11
98323__EMC_TRF
page 35 of 46
11 Surge
Immunity
11.1 Standard
Basic standard
EN 61000-4-5:2006
Date of testing
2008.2.25
Performance criteria:
B
11.2 Measurement equipment
Equipment
Last Calibration
Type
Serial No
.
Manufacturer
Immunity Simulator
February 25,
2008
2008
EMC PRO
SB2617
KEYTEK
11.3 Test set-up
See annex B
The EUT and the auxiliary equipment were placed on a table of 0.8m heights above a metal ground
reference plane. The size of ground plane is greater than 1m×1m and project beyond the EUT by at
least 0.1m on all sides. The ground plane is connected to the protective earth. The length of power
cord between the coupling device and the EUT was less than 2 meters (provided by the
manufacturer).
The surge noise shall be applied synchronized to the voltage phase at 0
The EUT and the auxiliary equipment were placed on a table of 0.8m heights above a metal ground
reference plane. The size of ground plane is greater than 1m×1m and project beyond the EUT by at
least 0.1m on all sides. The ground plane is connected to the protective earth. The length of power
cord between the coupling device and the EUT was less than 2 meters (provided by the
manufacturer).
The surge noise shall be applied synchronized to the voltage phase at 0
o
,90
o
,180
o
,270
o
and the peak
value of the a.c. voltage wave. (Positive and negative).
Each of Line-Line is impressed with a sequence of five surge voltages with interval of 1 min.
Each of Line-Line is impressed with a sequence of five surge voltages with interval of 1 min.
11.4 Test results
Mode
Table
Remarks
Result
TM1;
TM2
015
Tr/Th 1,2/50(8/20) μs
Line to line 1kV
Test to input a.c. power port
(Signal port can not directly
connect to outdoor cable)
connect to outdoor cable)
Pass
11.5 Table
11.5.1 Table 015
Injected
Line
Wave
Form
Voltage
(kV)
Phase
Number of
Pulse
Interval
time
Result
+1
0
o
,90
o
, 180
o
,270
o
20 60s
Pass
L-N
1.2/50μs
-1
0
o
,90
o
, 180
o
,270
o
20 60s
Pass
Ident. Nr.:
98323
Date:
2008-3-11
98323__EMC_TRF
page 36 of 46
12 Conducted
Immunity
12.1 Standard
Basic standard
EN 61000-4-6:1996/A1:2001
Date of testing
2008.2.25
Performance criteria:
A
12.2 Measurement equipment
Equipment
Last Calibration
Type
Serial No
.
Manufacturer
CW sine Generator
January 25,
2008
2008
CWS500 SB2605
EMTEST
CDN January
25,
2008
CDN-M2 SB2605/01
EMTEST
12.3 Test set-up
See annex B
The EUT are placed on a table that is 0.8 meter height, and a Ground reference plane on the table,
EUT are placed upon table and use a 10cm insulation between the EUT and Ground reference plane.
For Input DC and AC Power Ports: The EUT is connected to the power mains through a coupling and
decoupling networks for power supply lines. And directly couples the disturbances signal into EUT.
The EUT are placed on a table that is 0.8 meter height, and a Ground reference plane on the table,
EUT are placed upon table and use a 10cm insulation between the EUT and Ground reference plane.
For Input DC and AC Power Ports: The EUT is connected to the power mains through a coupling and
decoupling networks for power supply lines. And directly couples the disturbances signal into EUT.
12.4 Test results
Mode
Table
Remarks
Result
TM1;
TM2
016
1. Field Strength :3V(unmodulated,r.m.s)
2. Test Signal: AM 80% Modulated with 1kHz
3. Scanning Frequency :0.15MHz – 80MHz
4. Source impedance 150Ω
2. Test Signal: AM 80% Modulated with 1kHz
3. Scanning Frequency :0.15MHz – 80MHz
4. Source impedance 150Ω
Pass
12.5 Table
12.5.1 Table 016
Frequency Range
(MHz)
Injecteded Position
Strength
Result
0.15MHz ~ 80MHz
AC Lines
3V(r.m.s, Unmodulated)
Pass
Dwell time:0.5s; Steps: 1%