JBL ON STAGE 200ID (serv.man3) EMC - CB Certificate ▷ View online
Ident. Nr.:
98323
Date:
2008-3-11
98323__EMC_TRF
page 21 of 46
6 Harmonic
current
6.1 Standard
Basic standard
EN 61000-3-2:2006
Date of testing
2008.2.28
6.2 Measurement equipment
Equipment
Last Calibration
Type
Serial No
.
Manufacturer
Power
February 20, 2008 5001ix-CTS-400
SB2588
CI
Three Phase Harmonic
flicker test system
flicker test system
February 20, 2008 PACS-3
SB2588/01 CI
Power
February 20, 2008 5001ix-CTS-400-NO SB2588/02 CI
Power
February 20, 2008 5001ix-CTS-400-NO SB2588/03 CI
6.3 Test set-up
See annexe B
See annexe B
6.4 Classification of EUT
Devices with an active input power
of P < 50 W
of P < 50 W
Balanced three-phase equipment and all other
equipment, expect that stated in one of the
following classes
equipment, expect that stated in one of the
following classes
Class A
Portable tools
Class B
Lightning equipment, including dimming devices
Class C
Equipment having an input current with a "special
wave shape" as defined in figure 1 in the
standard and an active input power, P
wave shape" as defined in figure 1 in the
standard and an active input power, P
≤ 600 W
and motor driven with phase angle control
Class D
6.5 Harmonic current measurements
Steady state:
One time window equals 16 x 20 ms is measured and evaluated
Fluctuation:
A measurement time of 2,5 min is necessary for fluctuating
harmonics, one time window equals 16 x 20 ms, therefore during a
time of 2,5 min 469 time windows are measured and evaluated.
harmonics, one time window equals 16 x 20 ms, therefore during a
time of 2,5 min 469 time windows are measured and evaluated.
Continuous measurement:
A continuous measurement session is a long time measurement,
where always the last actual 2,5 min data is stored an evaluated in
real time. Each 320 ms a new data window is acquired and the oldest
is erased. If measured values are over the limit the measurement
stops automatically.
where always the last actual 2,5 min data is stored an evaluated in
real time. Each 320 ms a new data window is acquired and the oldest
is erased. If measured values are over the limit the measurement
stops automatically.
Ident. Nr.:
98323
Date:
2008-3-11
98323__EMC_TRF
page 22 of 46
6.6 Test results
Mode
Table
Remarks
Power
Result
TM1 009
230VAC
50Hz
11W
Pass*
TM2 010
230VAC
50Hz
9W
Pass*
*)
For devices with a rated power of 50 W or less, not being lighting equipment, no limit values are effective.
(EN61000-3-2)
(EN61000-3-2)
**)
For professionally used devices with a total rated power exceeding 1 kW no limit values are effective.
(EN61000-3-2)
(EN61000-3-2)
6.7 Table
6.7.1 Table 009
Harmonics – Class-A per A-14(Run time)
EUT: JBL200D
Tested by:
Test Margin: 100
Test date: 2/28/2008
Start time: 9:26:01 AM
End time: 9:28:41 AM
Test duration (min): 2.5
Data file name: H-000646.cts_data
Comment: ON
Customer:
Test Result: Pass
Customer:
Test Result: Pass
Source qualification: Normal
Current & voltage waveforms
-1.5
-1.0
-0.5
0.0
0.5
1.0
1.5
-300
-200
-100
0
100
200
300
Current (Amps)
Voltage (Volts)
Limits
Ident. Nr.:
98323
Date:
2008-3-11
98323__EMC_TRF
page 23 of 46
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Current RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
Test result: Pass Worst harmonic was #15 with 6.54% of the limit.
Ident. Nr.:
98323
Date:
2008-3-11
98323__EMC_TRF
page 24 of 46
Current Test Result Summary (Run time)
EUT: JBL200D
Tested by:
Test Margin: 100
Test date: 2/28/2008
Start time: 9:26:01 AM
End time: 9:28:41 AM
Test duration (min): 2.5
Data file name: H-000646.cts_data
Comment: ON
Customer:
Test Result: Pass
Customer:
Test Result: Pass
Source qualification: Normal
THC(A): 0.06 I-THD(pk%): 330.02 POHC(A): 0.015 POHC Limit(A): 0.251
Highest parameter values during test:
Highest parameter values during test:
V_RMS (Volts): 229.91
Frequency(Hz): 50.00
I_Peak (Amps): 1.032
I_RMS (Amps): 0.129
I_Fund (Amps): 0.048
Crest Factor:
10.554
Power (Watts): 11
Power Factor:
0.377
Harm# Harms(avg) 100%Limit %of
Limit Harms(max) 150%Limit %of
Limit Status
2 0.002 1.080 0.2
0.003 1.620 0.20
Pass
3 0.013 2.300 0.6
0.025 3.450 0.71
Pass
4 0.002 0.430 0.4
0.003 0.645 0.44
Pass
5 0.013 1.140 1.1
0.024 1.710 1.41
Pass
6 0.001 0.300 0.4
0.002 0.450 0.44
Pass
7 0.012 0.770 1.6
0.023 1.155 1.95
Pass
8 0.001 0.230 0.6
0.002 0.345 0.64
Pass
9 0.012 0.400 2.9
0.021 0.600 3.48
Pass
10 0.001 0.184 0.7
0.002 0.276 0.74
Pass
11 0.011 0.330 3.4
0.019 0.495 3.85
Pass
12 0.001 0.153 0.8
0.002 0.230 0.82
Pass
13 0.010 0.210 5.0
0.017 0.315 5.36
Pass
14 0.001 0.131 0.9
0.002 0.197 0.93
Pass
15 0.010 0.150 6.5
0.015 0.225 6.54
Pass
16 0.001 0.115 1.0
0.002 0.173 0.99
Pass
17 0.009 0.132 6.8
0.013 0.199 6.34
Pass
18 0.001 0.102 1.0
0.002 0.153 1.05
Pass
19 0.008 0.118 6.9
0.011 0.178 6.09
Pass
20 0.001 0.092 1.1
0.002 0.138 1.11
Pass
21 0.007 0.107 6.9
0.009 0.161 5.79
Pass
22 0.001 0.084 1.1
0.001 0.125 1.13
Pass
23 0.007 0.098 6.8
0.008 0.147 5.45
Pass
24 0.001 0.077 1.1
0.001 0.115 1.16
Pass
25 0.006 0.090 6.5
0.007 0.135 5.04
Pass
26 0.001 0.071 1.1
0.001 0.106 1.16
Pass
27 0.005 0.083 6.1
0.006 0.125 4.59
Pass
28 0.001 0.066 1.1
0.001 0.099 1.14
Pass
29 0.004 0.078 5.7
0.005 0.116 4.13
Pass
30 0.001 0.061 1.1
0.001 0.092 1.15
Pass
31 0.004 0.073 5.1
0.004 0.109 3.60
Pass
32 0.001 0.058 1.0
0.001 0.086 1.09
Pass
33 0.003 0.068 4.5
0.003 0.102 3.20
Pass
34 0.001 0.054 1.0
0.001 0.081 1.06
Pass
35 0.003 0.064 3.9
0.003 0.096 2.81
Pass
36 0.000 0.051 0.9
0.001 0.077 0.99
Pass
37 0.002 0.061 3.3
0.002 0.091 2.41
Pass
38 0.000 0.048 0.9
0.001 0.073 0.94
Pass
39 0.002 0.058 2.7
0.002 0.087 1.99
Pass
40 0.000 0.046 0.8
0.001 0.069 0.86
Pass
Click on the first or last page to see other ON STAGE 200ID (serv.man3) service manuals if exist.