DOWNLOAD JBL ON STAGE 200ID (serv.man3) Service Manual ↓ Size: 2.47 MB | Pages: 46 in PDF or view online for FREE

Model
ON STAGE 200ID (serv.man3)
Pages
46
Size
2.47 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-stage-200id-sm3.pdf
Date

JBL ON STAGE 200ID (serv.man3) EMC - CB Certificate ▷ View online

Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 21 of 46 
 
6 Harmonic 
current 
6.1 Standard 
Basic standard 
EN 61000-3-2:2006 
Date of testing 
2008.2.28 
6.2 Measurement equipment 
 
Equipment 
Last Calibration 
Type 
 
Serial No
Manufacturer
Power 
February 20, 2008  5001ix-CTS-400 
SB2588 
CI 
Three Phase Harmonic 
flicker test system 
February 20, 2008  PACS-3 
SB2588/01  CI 
Power 
February 20, 2008  5001ix-CTS-400-NO SB2588/02  CI 
Power 
February 20, 2008  5001ix-CTS-400-NO SB2588/03  CI 
6.3 Test set-up 
See annexe B   
6.4  Classification of EUT 
Devices with an active input power 
of P < 50 W 
 
 
Balanced three-phase equipment and all other 
equipment, expect that stated in one of the 
following classes 
Class A  
 
 
Portable tools 
Class B  
 
Lightning equipment, including dimming devices 
Class C  
 
Equipment having an input current with a "special 
wave shape" as defined in figure 1 in the 
standard and an active input power, P 
≤ 600 W 
and motor driven with phase angle control 
Class D  
 
 
   
  
6.5  Harmonic current measurements 
Steady state: 
One time window equals 16 x 20 ms is measured and evaluated 
Fluctuation: 
A measurement time of 2,5 min is necessary for fluctuating 
harmonics, one time window equals 16 x 20 ms, therefore during a 
time of 2,5 min 469 time windows are measured and evaluated. 
Continuous measurement: 
A continuous measurement session is a long time measurement, 
where always the last actual 2,5 min data is stored an evaluated in 
real time. Each 320 ms a new data window is acquired and the oldest 
is erased. If measured values are over the limit the measurement 
stops automatically. 
Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 22 of 46 
6.6 Test results 
Mode 
Table 
Remarks 
Power 
Result 
TM1 009 
230VAC 
50Hz 
11W 
Pass* 
TM2 010 
230VAC 
50Hz 
9W 
Pass* 
*) 
For devices with a rated power of 50 W or less, not being lighting equipment, no limit values are effective.
(EN61000-3-2) 
**) 
For professionally used devices with a total rated power exceeding 1 kW no limit values are effective. 
(EN61000-3-2) 
 
 
6.7 Table 
6.7.1  Table  009  
Harmonics – Class-A per A-14(Run time) 
 
EUT: JBL200D 
Tested by:  
Test Margin: 100 
Test date: 2/28/2008 
Start time: 9:26:01 AM 
End time: 9:28:41 AM 
Test duration (min): 2.5 
Data file name: H-000646.cts_data 
Comment: ON 
Customer:  
 
Test Result: Pass 
Source qualification: Normal 
 
Current & voltage waveforms 
  
 
-1.5
-1.0
-0.5
0.0
0.5
1.0
1.5
-300
-200
-100
0
100
200
300
  
Current (Amps)
Voltage (Volts)
 
Limits 
 
Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 23 of 46 
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
  
Current RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
 
 
Test result:  Pass     Worst harmonic was #15 with 6.54% of the limit.  
                 
 
 
                 
 
 
Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 24 of 46 
Current Test Result Summary (Run time) 
 
EUT: JBL200D 
Tested by:  
Test Margin: 100 
Test date: 2/28/2008 
Start time: 9:26:01 AM 
End time: 9:28:41 AM 
Test duration (min): 2.5 
Data file name: H-000646.cts_data 
Comment:  ON 
Customer:   
 
Test Result: Pass 
Source qualification:  Normal 
THC(A): 0.06       I-THD(pk%): 330.02         POHC(A):  0.015        POHC Limit(A):  0.251          
Highest parameter values during test: 
V_RMS (Volts):   229.91 
Frequency(Hz):   50.00 
I_Peak (Amps):  1.032 
I_RMS (Amps):  0.129 
I_Fund (Amps):  0.048 
Crest Factor: 
10.554 
Power (Watts):   11 
Power Factor: 
0.377 
 
Harm# Harms(avg) 100%Limit %of 
Limit  Harms(max) 150%Limit %of 
Limit Status 
 
 
2  0.002 1.080  0.2 
0.003 1.620  0.20 
Pass 
 
3  0.013 2.300  0.6 
0.025 3.450  0.71 
Pass 
 
4  0.002 0.430  0.4 
0.003 0.645  0.44 
Pass 
 
5  0.013 1.140  1.1 
0.024 1.710  1.41 
Pass 
 
6  0.001 0.300  0.4 
0.002 0.450  0.44 
Pass 
 
7  0.012 0.770  1.6 
0.023 1.155  1.95 
Pass 
 
8  0.001 0.230  0.6 
0.002 0.345  0.64 
Pass 
 
9  0.012 0.400  2.9 
0.021 0.600  3.48 
Pass 
 
10  0.001 0.184  0.7 
0.002 0.276  0.74 
Pass 
 
11  0.011 0.330  3.4 
0.019 0.495  3.85 
Pass 
 
12  0.001 0.153  0.8 
0.002 0.230  0.82 
Pass 
 
13  0.010 0.210  5.0 
0.017 0.315  5.36 
Pass 
 
14  0.001 0.131  0.9 
0.002 0.197  0.93 
Pass 
 
15  0.010 0.150  6.5 
0.015 0.225  6.54 
Pass 
 
16  0.001 0.115  1.0 
0.002 0.173  0.99 
Pass 
 
17  0.009 0.132  6.8 
0.013 0.199  6.34 
Pass 
 
18  0.001 0.102  1.0 
0.002 0.153  1.05 
Pass 
 
19  0.008 0.118  6.9 
0.011 0.178  6.09 
Pass 
 
20  0.001 0.092  1.1 
0.002 0.138  1.11 
Pass 
 
21  0.007 0.107  6.9 
0.009 0.161  5.79 
Pass 
 
22  0.001 0.084  1.1 
0.001 0.125  1.13 
Pass 
 
23  0.007 0.098  6.8 
0.008 0.147  5.45 
Pass 
 
24  0.001 0.077  1.1 
0.001 0.115  1.16 
Pass 
 
25  0.006 0.090  6.5 
0.007 0.135  5.04 
Pass 
 
26  0.001 0.071  1.1 
0.001 0.106  1.16 
Pass 
 
27  0.005 0.083  6.1 
0.006 0.125  4.59 
Pass 
 
28  0.001 0.066  1.1 
0.001 0.099  1.14 
Pass 
 
29  0.004 0.078  5.7 
0.005 0.116  4.13 
Pass 
 
30  0.001 0.061  1.1 
0.001 0.092  1.15 
Pass 
 
31  0.004 0.073  5.1 
0.004 0.109  3.60 
Pass 
 
32  0.001 0.058  1.0 
0.001 0.086  1.09 
Pass 
 
33  0.003 0.068  4.5 
0.003 0.102  3.20 
Pass 
 
34  0.001 0.054  1.0 
0.001 0.081  1.06 
Pass 
 
35  0.003 0.064  3.9 
0.003 0.096  2.81 
Pass 
 
36  0.000 0.051  0.9 
0.001 0.077  0.99 
Pass 
 
37  0.002 0.061  3.3 
0.002 0.091  2.41 
Pass 
 
38  0.000 0.048  0.9 
0.001 0.073  0.94 
Pass 
 
39  0.002 0.058  2.7 
0.002 0.087  1.99 
Pass 
 
40  0.000 0.046  0.8 
0.001 0.069  0.86 
Pass 
 
 
  
Page of 46