DOWNLOAD JBL ON STAGE 200ID (serv.man3) Service Manual ↓ Size: 2.47 MB | Pages: 46 in PDF or view online for FREE

Model
ON STAGE 200ID (serv.man3)
Pages
46
Size
2.47 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-stage-200id-sm3.pdf
Date

JBL ON STAGE 200ID (serv.man3) EMC - CB Certificate ▷ View online

Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 13 of 46 
4.5.2 Diagram 002 
Conducted Disturbance
EUT:           
M/N:JBL200D
Op Cond:       
Connect to PC
Test Spec:     
N
Comment:       
AC 230V/50Hz
   0
  10
  20
  30
  40
  50
  60
dBuV
  70
0.15
MHz
30
1
10
ConQP
ConAV
Mkr  :    1.62000MHz   41.2 dBuV
 
 
 
 
 
 
 
 
 
Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 14 of 46 
4.5.3 Diagram 003 
Conducted Disturbance
EUT:           
M/N:JBL200D
Op Cond:       
Connect to  iPod
Test Spec:     
L
Comment:       
AC 230V/50Hz
   0
  10
  20
  30
  40
  50
  60
dBuV
  70
0.15
MHz
30
1
10
ConQP
ConAV
Mkr  :    5.83000MHz   34.4 dBuV
 
 
 
 
 
 
 
 
 
Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 15 of 46 
4.5.4 Diagram 004 
Conducted Disturbance
EUT:           
M/N:JBL200D
Op Cond:       
Connect to iPod
Test Spec:     
N
Comment:       
AC 230V/50Hz
   0
  10
  20
  30
  40
  50
  60
dBuV
  70
0.15
MHz
30
1
10
ConQP
ConAV
Mkr  :    1.62000MHz   41.2 dBuV
 
 
 
 
  
Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 16 of 46 
 
4.5.5 Table 005 
Test mode:TM1  
QuasiPeak 
(dBμV) 
Average 
(dBμV) 
QuasiPeak 
(dBμV) 
Average 
(dBμV) 
Frequency 
(MHz) 
Test 
value 
limit 
Test 
value 
limit 
Frequency
(MHz) 
Test 
value 
limit 
Test 
value 
limit
0.162  46.2 65.4 29.6 55.4  0.150 
47.0 
66  21.6  56 
0.194  43.0 63.9 27.2 53.9  0.162 
47.1  65.4  30.5 55.4
0.246  37.6 61.9 24.4 51.9  0.194 
43.0  63.9  29.2 57.9
0.382  37.4 58.2 29.0 48.2  0.226 
39.3  62.6  22.7 52.6
16.945 45.9 60 41.3 50  16.925  45.3  60  39.3 50 
18.140 32.4 60 25.4 50  12.485  41.0  60  36.7 50 
Test mode:TM2 
QuasiPeak 
(dBμV) 
Average 
(dBμV) 
QuasiPeak 
(dBμV) 
Average 
(dBμV) 
Frequency 
(MHz) 
Test 
value 
limit 
Test 
value 
limit 
Frequency
(MHz) 
Test 
value 
limit 
Test 
value 
limit
0.150 46.8 
66 
33.2 
56  0.154  47.2 65.8 
32.2 
55.8
0.194  41.5 63.7 25.3 53.7  0.162 
38.3  64.0  19.7 54.0
0.374  36.7 58.4 28.6 48.4  0.218 
37.8  62.9  21.1 52.9
0.860 28.4 
56 
21.2 
46  0.342  27.7 59.1 
18.1 
49.1
5.830 31.1 
60 
26.1 
50  1.620  23.8  56 14.6 
46 
The emissions don’t show are too low against the limits, the test curves are shown above. 
Page of 46
Display