DOWNLOAD JBL ON STAGE 200ID (serv.man3) Service Manual ↓ Size: 2.47 MB | Pages: 46 in PDF or view online for FREE

Model
ON STAGE 200ID (serv.man3)
Pages
46
Size
2.47 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-stage-200id-sm3.pdf
Date

JBL ON STAGE 200ID (serv.man3) EMC - CB Certificate ▷ View online

Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 25 of 46 
Voltage Source Verification Data (Run time) 
 
EUT: JBL200D 
Tested by:  
Test Margin: 100 
Test date: 2/28/2008 
Start time: 9:26:01 AM 
End time: 9:28:41 AM 
Test duration (min): 2.5 
Data file name: H-000646.cts_data 
Comment:  ON 
Customer:   
 
Test Result: Pass 
Source qualification: Normal  
 
Highest parameter values during test: 
Voltage (Vrms):   229.91 
Frequency(Hz):   50.00 
I_Peak (Amps):  1.032 
I_RMS (Amps):  0.129 
I_Fund (Amps):  0.048 
Crest Factor: 
10.554 
Power (Watts):   11 
Power Factor: 
0.377 
 
Harm# Harmonics 
V-rms Limit 
V-rms % 
of 
Limit  Status 
 
 2 
0.123 
0.460 
26.69 
OK 
 3 
0.445 
2.069 
21.52 
OK 
 4 
0.106 
0.460 
23.13 
OK 
 5 
0.031 
0.919 
3.38 
OK 
 6 
0.061 
0.460 
13.34 
OK 
 7 
0.028 
0.690 
4.07 
OK 
 8 
0.025 
0.460 
5.50 
OK 
 9 
0.043 
0.460 
9.41 
OK 
 10 
0.031 
0.460 
6.84 
OK 
 11 
0.032 
0.230 
13.73 
OK 
 12 
0.017 
0.230 
7.30 
OK 
 13 
0.010 
0.230 
4.37 
OK 
 14 
0.012 
0.230 
5.15 
OK 
 15 
0.015 
0.230 
6.68 
OK 
 16 
0.017 
0.230 
7.27 
OK 
 17 
0.012 
0.230 
5.07 
OK 
 18 
0.014 
0.230 
6.24 
OK 
 19 
0.015 
0.230 
6.61 
OK 
 20 
0.020 
0.230 
8.67 
OK 
 21 
0.011 
0.230 
4.69 
OK 
 22 
0.009 
0.230 
3.73 
OK 
 23 
0.014 
0.230 
5.90 
OK 
 24 
0.007 
0.230 
2.99 
OK 
 25 
0.009 
0.230 
3.94 
OK 
 26 
0.010 
0.230 
4.52 
OK 
 27 
0.012 
0.230 
5.03 
OK 
 28 
0.008 
0.230 
3.31 
OK 
 29 
0.006 
0.230 
2.46 
OK 
 30 
0.010 
0.230 
4.15 
OK 
 31 
0.009 
0.230 
3.92 
OK 
 32 
0.008 
0.230 
3.29 
OK 
 33 
0.006 
0.230 
2.78 
OK 
 34 
0.005 
0.230 
2.31 
OK 
 35 
0.008 
0.230 
3.55 
OK 
 36 
0.005 
0.230 
2.15 
OK 
 37 
0.005 
0.230 
1.98 
OK 
 38 
0.003 
0.230 
1.50 
OK 
 39 
0.006 
0.230 
2.50 
OK 
 40 
0.011 
0.230 
4.67 
OK 
 
 
 
 
 
 
 
 
Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 26 of 46 
6.7.2  Table  010 
Harmonics – Class-A per A-14(Run time) 
 
EUT: JBL2000D 
Tested by:  
Test Margin: 100 
Test date: 2/27/2008 
Start time: 11:03:33 AM 
End time: 11:06:13 AM 
Test duration (min): 2.5 
Data file name: H-000619.cts_data 
Comment: Connect to ipod 
Customer:  
 
Test Result: Pass 
Source qualification: Normal 
 
Current & voltage waveforms 
  
 
-0.6
-0.4
-0.2
0.0
0.2
0.4
0.6
-300
-200
-100
0
100
200
300
  
Current (Amps)
Voltage (Volts)
 
Limits 
 
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
  
Current RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
 
 
Test result:  Pass     Worst harmonic was #15 with 9.98% of the limit.  
                 
 
 
                 
 
 
Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 27 of 46 
Current Test Result Summary (Run time) 
 
EUT: JBL2000D 
Tested by:  
Test Margin: 100 
Test date: 2/27/2008 
Start time: 11:03:33 AM 
End time: 11:06:13 AM 
Test duration (min): 2.5 
Data file name: H-000619.cts_data 
Comment:  Connect to ipod 
Customer:   
 
Test Result: Pass 
Source qualification:  Normal 
THC(A): 0.09       I-THD(pk%): 235.06         POHC(A):  0.021        POHC Limit(A):  0.251          
Highest parameter values during test: 
V_RMS (Volts):   229.92 
Frequency(Hz):   50.00 
I_Peak (Amps):  0.482 
I_RMS (Amps):  0.097 
I_Fund (Amps):  0.038 
Crest Factor: 
5.100 
Power (Watts):   9 
Power Factor: 
0.392 
 
Harm# Harms(avg) 100%Limit %of 
Limit  Harms(max) 150%Limit %of 
Limit Status 
 
 
2  0.002 1.080  0.2 
0.003 1.620  0.17 
Pass 
 
3  0.035 2.300  1.5 
0.037 3.450  1.07 
Pass 
 
4  0.001 0.430  0.3 
0.003 0.645  0.41 
Pass 
 
5  0.034 1.140  2.9 
0.035 1.710  2.04 
Pass 
 
6  0.001 0.300  0.4 
0.002 0.450  0.42 
Pass 
 
7  0.032 0.770  4.1 
0.033 1.155  2.85 
Pass 
 
8  0.001 0.230  0.5 
0.002 0.345  0.60 
Pass 
 
9  0.030 0.400  7.5 
0.031 0.600  5.15 
Pass 
 
10  0.001 0.184  0.6 
0.002 0.276  0.70 
Pass 
 
11  0.027 0.330  8.3 
0.028 0.495  5.73 
Pass 
 
12  0.001 0.153  0.7 
0.002 0.230  0.77 
Pass 
 
13  0.025 0.210  11.8 
0.025 0.315  8.07 
Pass 
 
14  0.001 0.131  0.8 
0.002 0.197  0.90 
Pass 
 
15  0.022 0.150  14.6 
0.022 0.225  9.98 
Pass 
 
16  0.001 0.115  0.8 
0.002 0.173  0.91 
Pass 
 
17  0.019 0.132  14.3 
0.019 0.199  9.73 
Pass 
 
18  0.001 0.102  0.9 
0.002 0.153  1.01 
Pass 
 
19  0.016 0.118  13.5 
0.016 0.178  9.13 
Pass 
 
20  0.001 0.092  0.9 
0.001 0.138  1.00 
Pass 
 
21  0.013 0.107  12.3 
0.013 0.161  8.30 
Pass 
 
22  0.001 0.084  0.9 
0.001 0.125  1.03 
Pass 
 
23  0.011 0.098  10.7 
0.011 0.147  7.29 
Pass 
 
24  0.001 0.077  0.9 
0.001 0.115  1.02 
Pass 
 
25  0.008 0.090  9.1 
0.008 0.135  6.21 
Pass 
 
26  0.001 0.071  0.9 
0.001 0.106  1.00 
Pass 
 
27  0.006 0.083  7.4 
0.006 0.125  5.12 
Pass 
 
28  0.001 0.066  0.9 
0.001 0.099  0.99 
Pass 
 
29  0.005 0.078  6.0 
0.005 0.116  4.18 
Pass 
 
30  0.001 0.061  0.8 
0.001 0.092  0.98 
Pass 
 
31  0.004 0.073  5.0 
0.004 0.109  3.47 
Pass 
 
32  0.000 0.058  0.9 
0.001 0.086  0.99 
Pass 
 
33  0.003 0.068  4.5 
0.003 0.102  3.20 
Pass 
 
34  0.000 0.054  0.8 
0.001 0.081  0.98 
Pass 
 
35  0.003 0.064  4.5 
0.003 0.096  3.21 
Pass 
 
36  0.000 0.051  0.8 
0.001 0.077  0.98 
Pass 
 
37  0.003 0.061  4.7 
0.003 0.091  3.32 
Pass 
 
38  0.000 0.048  0.8 
0.001 0.073  0.97 
Pass 
 
39  0.003 0.058  4.8 
0.003 0.087  3.41 
Pass 
 
40  0.000 0.046  0.8 
0.001 0.069  0.97 
Pass 
 
 
  
Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 28 of 46 
Voltage Source Verification Data (Run time) 
 
EUT: JBL2000D 
Tested by:  
Test Margin: 100 
Test date: 2/27/2008 
Start time: 11:03:33 AM 
End time: 11:06:13 AM 
Test duration (min): 2.5 
Data file name: H-000619.cts_data 
Comment:  Connect to ipod 
Customer:   
 
Test Result: Pass 
Source qualification: Normal  
 
Highest parameter values during test: 
Voltage (Vrms):   229.92 
Frequency(Hz):   50.00 
I_Peak (Amps):  0.482 
I_RMS (Amps):  0.097 
I_Fund (Amps):  0.038 
Crest Factor: 
5.100 
Power (Watts):   9 
Power Factor: 
0.392 
 
Harm# Harmonics 
V-rms Limit 
V-rms % 
of 
Limit  Status 
 
 2 
0.123 
0.460 
26.86 
OK 
 3 
0.459 
2.069 
22.16 
OK 
 4 
0.100 
0.460 
21.76 
OK 
 5 
0.028 
0.920 
2.99 
OK 
 6 
0.038 
0.460 
8.20 
OK 
 7 
0.036 
0.690 
5.24 
OK 
 8 
0.028 
0.460 
6.18 
OK 
 9 
0.034 
0.460 
7.30 
OK 
 10 
0.030 
0.460 
6.50 
OK 
 11 
0.032 
0.230 
13.81 
OK 
 12 
0.008 
0.230 
3.68 
OK 
 13 
0.010 
0.230 
4.40 
OK 
 14 
0.011 
0.230 
4.63 
OK 
 15 
0.022 
0.230 
9.71 
OK 
 16 
0.014 
0.230 
6.24 
OK 
 17 
0.011 
0.230 
4.94 
OK 
 18 
0.015 
0.230 
6.50 
OK 
 19 
0.022 
0.230 
9.53 
OK 
 20 
0.021 
0.230 
8.95 
OK 
 21 
0.008 
0.230 
3.31 
OK 
 22 
0.009 
0.230 
4.10 
OK 
 23 
0.017 
0.230 
7.31 
OK 
 24 
0.004 
0.230 
1.73 
OK 
 25 
0.007 
0.230 
3.15 
OK 
 26 
0.010 
0.230 
4.46 
OK 
 27 
0.012 
0.230 
5.42 
OK 
 28 
0.008 
0.230 
3.54 
OK 
 29 
0.010 
0.230 
4.25 
OK 
 30 
0.008 
0.230 
3.64 
OK 
 31 
0.007 
0.230 
3.13 
OK 
 32 
0.008 
0.230 
3.37 
OK 
 33 
0.008 
0.230 
3.59 
OK 
 34 
0.003 
0.230 
1.44 
OK 
 35 
0.003 
0.230 
1.41 
OK 
 36 
0.005 
0.230 
2.20 
OK 
 37 
0.009 
0.230 
3.91 
OK 
 38 
0.002 
0.230 
0.87 
OK 
 39 
0.005 
0.230 
2.02 
OK 
 40 
0.011 
0.230 
4.64 
OK 
 
 
 
 
Page of 46
Display

Click on the first or last page to see other ON STAGE 200ID (serv.man3) service manuals if exist.