JBL ON STAGE 200ID (serv.man2) EMC - CB Certificate ▷ View online
Ident. Nr.:
111931
Date:
2008-09-09
111931 EMC TRF_verified
page 17 of 50
5.5.2 Diagram 007
Ident. Nr.:
111931
Date:
2008-09-09
111931 EMC TRF_verified
page 18 of 50
5.5.3 Table 008
TM
Emission Frequency
MHz
Measured QP Level
dB
μV/m
Polarity
Limit
dB
μV/m
33.334 39.0
V
40
71.871 34.5
V
40
185.170 36.8
V
40
193.591 37.9
H
40
220.466 39.7
H
40
TM1
730.979 44.0
H
47
39.850 33.5
V
40
47.275 35.8
V
40
77.978 35.2
V
40
TM2
185.090 35.7
V
40
The emissions don’t show are too low against the limits, the test curves are shown above.
Ident. Nr.:
111931
Date:
2008-09-09
111931 EMC TRF_verified
page 19 of 50
6 Harmonic
current
6.1 Standard
Basic standard
EN 61000-3-2:2006
Date of testing
2008-09-02
6.2 Measurement equipment
Equipment
Last Calibration
Type
Serial No
.
Manufacturer
Power
February 20, 2008 5001ix-CTS-400
SB2588
CI
Three Phase Harmonic
flicker test system
flicker test system
February 20, 2008 PACS-3
SB2588/01 CI
Power
February 20, 2008 5001ix-CTS-400-NO SB2588/02 CI
Power
February 20, 2008 5001ix-CTS-400-NO SB2588/03 CI
6.3 Test set-up
See annexe B
See annexe B
6.4 Classification of EUT
Devices with an active input power
of P <75 W
of P <75 W
Balanced three-phase equipment and all other
equipment, expect that stated in one of the
following classes
equipment, expect that stated in one of the
following classes
Class A
Portable tools
Class B
Lightning equipment, including dimming devices
Class C
Equipment having an input current with a "special
wave shape" as defined in figure 1 in the
standard and an active input power, P
wave shape" as defined in figure 1 in the
standard and an active input power, P
≤ 600 W
and motor driven with phase angle control
Class D
The power cord of the EUT is connected to the output of the test systems , Turn on the power of the
EUT and use the test system to test the harmonic current level.Observation time: 150s
EUT and use the test system to test the harmonic current level.Observation time: 150s
If Harmonic current less than 0.6% of the input current measured under the test condition ,or less
than 5mA, then whichever is greater,are disregarded.
than 5mA, then whichever is greater,are disregarded.
Ident. Nr.:
111931
Date:
2008-09-09
111931 EMC TRF_verified
page 20 of 50
6.5 Test results
Mode
Table
Remarks
Power
Result
TM1 009
230VAC
50Hz
6.5W
No limit *
TM2 010
230VAC
50Hz
6.7W
No limit *
*)
For devices with a rated power of 75 W or less, not being lighting equipment, no limit values are effective.
(EN61000-3-2)
(EN61000-3-2)
**)
For professionally used devices with a total rated power exceeding 1 kW no limit values are effective.
(EN61000-3-2)
(EN61000-3-2)
6.6 Table
6.6.1 Table 009
Harmonics – Class-A per Ed. 3.0 (2006)(Run time)
EUT: jbl-on stage-200iD
Tested by: Test Operator
Start time: 4:56:05 PM
End time: 4:58:56 PM
Test duration (min): 2.5
Data file name: H-000232.cts_data
Comment: Connect to PC
Customer: Customer
Test Result: Pass Source qualification: Normal
Current & voltage waveforms
Customer: Customer
Test Result: Pass Source qualification: Normal
Current & voltage waveforms
-0.6
-0.4
-0.2
0.0
0.2
0.4
0.6
-300
-200
-100
0
100
200
300
Current (Amps)
Voltage (Volts)
Limits
Click on the first or last page to see other ON STAGE 200ID (serv.man2) service manuals if exist.