JBL ON STAGE 200ID (serv.man2) EMC - CB Certificate ▷ View online

Ident. Nr.: 
111931 
Date:  
2008-09-09 
 
111931 EMC TRF_verified 
page 17 of 50 
5.5.2  Diagram 007                                    
 
 
 
 
 
 
 
Ident. Nr.: 
111931 
Date:  
2008-09-09 
 
111931 EMC TRF_verified 
page 18 of 50 
5.5.3 Table 008 
 
TM  
 
Emission Frequency
MHz 
Measured QP Level  
dB
μV/m 
Polarity 
Limit 
dB
μV/m 
33.334 39.0 
40 
71.871 34.5 
40 
185.170 36.8 
40 
193.591 37.9 
40 
220.466 39.7 
40 
TM1 
730.979 44.0 
47 
39.850 33.5 
40 
47.275 35.8 
40 
77.978 35.2 
40 
TM2 
185.090 35.7 
40 
The emissions don’t show are too low against the limits, the test curves are shown above. 
Ident. Nr.: 
111931 
Date:  
2008-09-09 
 
111931 EMC TRF_verified 
page 19 of 50 
 
6 Harmonic 
current 
6.1 Standard 
Basic standard 
EN 61000-3-2:2006 
Date of testing 
2008-09-02 
6.2 Measurement equipment 
 
Equipment 
Last Calibration 
Type 
 
Serial No
Manufacturer
Power 
February 20, 2008  5001ix-CTS-400 
SB2588 
CI 
Three Phase Harmonic 
flicker test system 
February 20, 2008  PACS-3 
SB2588/01  CI 
Power 
February 20, 2008  5001ix-CTS-400-NO SB2588/02  CI 
Power 
February 20, 2008  5001ix-CTS-400-NO SB2588/03  CI 
6.3 Test set-up 
See annexe B   
6.4  Classification of EUT 
Devices with an active input power 
of P <75 W 
 
 
Balanced three-phase equipment and all other 
equipment, expect that stated in one of the 
following classes 
Class A  
 
 
Portable tools 
Class B  
 
Lightning equipment, including dimming devices 
Class C  
 
Equipment having an input current with a "special 
wave shape" as defined in figure 1 in the 
standard and an active input power, P 
≤ 600 W 
and motor driven with phase angle control 
Class D  
 
The power cord of the EUT is connected to the output of the test systems , Turn on the power of the 
EUT and use the test system to test the harmonic current level.Observation time: 150s 
If Harmonic current less than 0.6% of the input current measured under the test condition ,or less 
than 5mA, then whichever is greater,are disregarded. 
Ident. Nr.: 
111931 
Date:  
2008-09-09 
 
111931 EMC TRF_verified 
page 20 of 50 
6.5 Test results 
Mode 
Table 
Remarks 
Power 
Result 
TM1 009 
230VAC 
50Hz 
6.5W 
No limit * 
TM2 010 
230VAC 
50Hz 
6.7W 
No limit * 
*) 
For devices with a rated power of 75 W or less, not being lighting equipment, no limit values are effective.
(EN61000-3-2) 
**) 
For professionally used devices with a total rated power exceeding 1 kW no limit values are effective. 
(EN61000-3-2) 
 
 
6.6 Table 
6.6.1  Table  009  
Harmonics – Class-A per Ed. 3.0 (2006)(Run time) 
 
EUT: jbl-on stage-200iD 
Tested by: Test Operator 
Start time: 4:56:05 PM 
End time: 4:58:56 PM 
Test duration (min): 2.5 
Data file name: H-000232.cts_data 
Comment: Connect to PC 
Customer: Customer 
 
Test Result: Pass          Source qualification: Normal 
 
Current & voltage waveforms 
  
 
-0.6
-0.4
-0.2
0.0
0.2
0.4
0.6
-300
-200
-100
0
100
200
300
  
Current (Amps)
Voltage (Volts)
 
Limits 
 