JBL ON STAGE 200ID (serv.man2) EMC - CB Certificate ▷ View online
Ident. Nr.:
111931
Date:
2008-09-09
111931 EMC TRF_verified
page 33 of 50
10 Electrical
Fast
Transients/Bursts Immunity
10.1 Standard
Basic standard
EN 61000-4-4:2004
Date of testing
2008-09-02
Performance criteria:
B
10.2 Measurement equipment
Equipment
Last Calibration
Type
Serial No
.
Manufacturer
EFT simulator
February 25,
2008
2008
NSG2025-1 SB2556 SCHNAFFNER
10.3 Test set-up
See annex B
The EUT is placed on a table that is 0.8meter height. A ground reference plane is placed on the table,
and uses a 0.1m insulation between the EUT and ground reference plane.
The minimum area of the ground reference plane is 1m*1m, and projected beyond the EUT by at least
0.1m on all sides.
Test on power supply ports:
The duration time of each test sequential was 1 minute.
The length of the signal and power lines between the coupling device and the EUT is 0.5m.
The EUT is placed on a table that is 0.8meter height. A ground reference plane is placed on the table,
and uses a 0.1m insulation between the EUT and ground reference plane.
The minimum area of the ground reference plane is 1m*1m, and projected beyond the EUT by at least
0.1m on all sides.
Test on power supply ports:
The duration time of each test sequential was 1 minute.
The length of the signal and power lines between the coupling device and the EUT is 0.5m.
10.4 Test results
Mode
Table
Remarks
Result
TM1
&TM2
015
±
1KV
Tr/Th: 5/50ns
Repetition frequency:5kHz
Test to input a.c. power port
(Signal port cable is less than 3m)
Pass
10.5 Table
10.5.1 Table 015
Injected Line
Voltage
(kV)
Duration time
(s)
Injected Method
Result
+1 60
Direct
Pass
L
-1 60
Direct
Pass
+1 60
Direct
Pass
N
-1 60
Direct
Pass
+1 60
Direct
Pass
L,N
-1 60
Direct
Pass
Ident. Nr.:
111931
Date:
2008-09-09
111931 EMC TRF_verified
page 34 of 50
11 Surge
Immunity
11.1 Standard
Basic standard
EN 61000-4-5:2006
Date of testing
2008-09-02
Performance criteria:
B
11.2 Measurement equipment
Equipment
Last Calibration
Type
Serial No
.
Manufacturer
Immunity simulator
February 25,
2008
2008
UCS5500M4
SB3070
EMTEST
Three Phase Coupling
Network
February 25,
2008
2008
CNI5036 SB3070/01
EMTEST
11.3 Test set-up
See annex B
The EUT and the auxiliary equipment were placed on a table of 0.8m heights above a metal ground
reference plane. The size of ground plane is greater than 1m×1m and project beyond the EUT by at
least 0.1m on all sides. The ground plane is connected to the protective earth. The length of power
cord between the coupling device and the EUT was less than 2 meters (provided by the
manufacturer).
The surge noise shall be applied synchronized to the voltage phase at 0
The EUT and the auxiliary equipment were placed on a table of 0.8m heights above a metal ground
reference plane. The size of ground plane is greater than 1m×1m and project beyond the EUT by at
least 0.1m on all sides. The ground plane is connected to the protective earth. The length of power
cord between the coupling device and the EUT was less than 2 meters (provided by the
manufacturer).
The surge noise shall be applied synchronized to the voltage phase at 0
o
,90
o
,180
o
,270
o
and the peak
value of the a.c. voltage wave. (Positive and negative).
Each of Line-Line is impressed with a sequence of five surge voltages with interval of 1 min.
Each of Line-Line is impressed with a sequence of five surge voltages with interval of 1 min.
11.4 Test results
Mode
Table
Remarks
Result
TM1
&TM2
016
Tr/Th 1,2/50(8/20)
μs
Line to line 1kV
Line to Gnd 2kV
Repetition frequency 5kHz
Test to input a.c. power port
(Signal port can not directly
connect to outdoor cable)
connect to outdoor cable)
Pass
11.5 Table
11.5.1 Table 016
Injected
Line
Wave
Form
Voltage
(kV)
Phase
Number of
Pulse
Interval
time
Result
+1
0
o
,90
o
, 180
o
,270
o
20 60s
Pass
L-N
1.2/50μs
-1
0
o
,90
o
, 180
o
,270
o
20 60s
Pass
Ident. Nr.:
111931
Date:
2008-09-09
111931 EMC TRF_verified
page 35 of 50
12 Conducted
Immunity
12.1 Standard
Basic standard
EN 61000-4-6:1996/A1:2001
Date of testing
2008-09-02
Performance criteria:
A
12.2 Measurement equipment
Equipment
Last Calibration
Type
Serial No
.
Manufacturer
CW sine Generator
January 25,
2008
2008
CWS500 SB2605
EMTEST
CDN January
25,
2008
CDN-M2 SB2605/01
EMTEST
12.3 Test set-up
See annex B
The EUT are placed on a table that is 0.8 meter height, and a Ground reference plane on the table,
EUT are placed upon table and use a 10cm insulation between the EUT and Ground reference plane.
For Input DC and AC Power Ports: The EUT is connected to the power mains through a coupling and
decoupling networks for power supply lines. And directly couples the disturbances signal into EUT.
The EUT are placed on a table that is 0.8 meter height, and a Ground reference plane on the table,
EUT are placed upon table and use a 10cm insulation between the EUT and Ground reference plane.
For Input DC and AC Power Ports: The EUT is connected to the power mains through a coupling and
decoupling networks for power supply lines. And directly couples the disturbances signal into EUT.
12.4 Test results
Mode
Table
Remarks
Result
TM1
&TM2
017
1. Field Strength :3V(unmodulated,r.m.s)
2. Test Signal: AM 80% Modulated with 1kHz
3. Scanning Frequency :0.15MHz – 80MHz
4. Source impedance 150Ω
2. Test Signal: AM 80% Modulated with 1kHz
3. Scanning Frequency :0.15MHz – 80MHz
4. Source impedance 150Ω
Pass
12.5 Table
12.5.1 Table 017
Frequency Range
(MHz)
Injecteded Position
Strength
Result
0.15MHz ~ 80MHz
AC Lines
3V(r.m.s, Unmodulated)
Pass
Dwell time:1s; Steps: 1%
Ident. Nr.:
111931
Date:
2008-09-09
111931 EMC TRF_verified
page 36 of 50
13 Voltage dips and interruptions Immunity
13.1 Standard
Basic standard
EN 61000-4-11:2004
Date of testing
2008-09-02
13.2 Measurement equipment
Equipment
Last Calibration
Type
Serial No
.
Manufacturer
Immunity simulator
February 25,
2008
2008
UCS5500M4
SB3070
EMTEST
Three Phase Coupling
Network
February 25,
2008
2008
CNI5036 SB3070/01
EMTEST
13.3 Test set-up
See annex B
The EUT and its load are placed on a table which is 0.8 meter above a metal ground plane measured
1m*1m min. And projected beyond the EUT by at least 0.1m on all sides. The power cord shall be used
the shortest power cord as specified by the manufacturer.
1m*1m min. And projected beyond the EUT by at least 0.1m on all sides. The power cord shall be used
the shortest power cord as specified by the manufacturer.
The EUT is tested for each selected combination of test level and duration with a sequence of three
dips/interruptions with intervals of 10s minimum.
dips/interruptions with intervals of 10s minimum.
13.4 Test results
Mode
Table
Remarks
Result
TM1
&TM2
&TM2
018
>95% reduction 0.5 period :performance criterion B
30% reduction 25 period :performance criterion C
>95% reduction 250 period :performance criterion C
Pass
13.5 Table
13.5.1 Table 018
Environmental
phenomenon
phenomenon
Voltage Dips & Short
Interruptions
Interruptions
% U
T
Duration
(ms)
Phase Angle
Result
>95 10
0
°
Pass
Voltage dips
30 500
0
°
Pass
Voltage
interruptions
interruptions
>95 5000
0
°
Pass