JBL ON STAGE 200ID (serv.man2) EMC - CB Certificate ▷ View online
Ident. Nr.:
111931
Date:
2008-09-09
111931 EMC TRF_verified
page 21 of 50
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Current RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
Test result: Pass Worst harmonic was #17 with 11.85% of the limit.
Ident. Nr.:
111931
Date:
2008-09-09
111931 EMC TRF_verified
page 22 of 50
Current Test Result Summary (Run time)
EUT: jbl-on stage-200iD
Tested by: Test Operator
Start time: 4:56:05 PM
End time: 4:58:56 PM
Test duration (min): 2.5
Data file name: H-000232.cts_data
Comment: Connect to PC
Customer: Customer
Test Result: Pass Source qualification: Normal
THC(A): 0.07 I-THD(%): 223.88 POHC(A): 0.022 POHC Limit(A): 0.265
Highest parameter values during test:
Customer: Customer
Test Result: Pass Source qualification: Normal
THC(A): 0.07 I-THD(%): 223.88 POHC(A): 0.022 POHC Limit(A): 0.265
Highest parameter values during test:
V_RMS (Volts): 230.07
Frequency(Hz): 50.00
I_Peak (Amps): 0.440
I_RMS (Amps): 0.080
I_Fund (Amps): 0.031
Crest Factor:
5.907
Power (Watts): 6.5
Power Factor:
0.356
Harm# Harms(avg) 100%Limit %of
Limit Harms(max) 150%Limit %of
Limit Status
2 0.001 1.080 0.0
0.003 1.620 0.16
Pass
3 0.028 2.300 1.2
0.029 3.450 0.83
Pass
4 0.001 0.430 0.0
0.002 0.645 0.31
Pass
5 0.026 1.140 2.3
0.027 1.710 1.55
Pass
6 0.001 0.300 0.0
0.001 0.450 0.28
Pass
7 0.025 0.770 3.3
0.025 1.155 2.20
Pass
8 0.001 0.230 0.0
0.001 0.345 0.42
Pass
9 0.024 0.400 5.9
0.024 0.600 3.95
Pass
10 0.001 0.184 0.0
0.001 0.276 0.48
Pass
11 0.022 0.330 6.6
0.022 0.495 4.43
Pass
12 0.001 0.153 0.0
0.001 0.230 0.58
Pass
13 0.020 0.210 9.4
0.020 0.315 6.31
Pass
14 0.001 0.131 0.0
0.001 0.197 0.66
Pass
15 0.018 0.150 11.8
0.018 0.225 7.92
Pass
16 0.001 0.115 0.0
0.001 0.173 0.75
Pass
17 0.016 0.132 11.9
0.016 0.199 7.91
Pass
18 0.001 0.102 0.0
0.001 0.153 0.81
Pass
19 0.014 0.118 11.6
0.014 0.178 7.76
Pass
20 0.001 0.092 0.0
0.001 0.138 0.85
Pass
21 0.012 0.107 11.1
0.012 0.161 7.46
Pass
22 0.001 0.084 0.0
0.001 0.125 0.88
Pass
23 0.010 0.098 10.6
0.010 0.147 7.09
Pass
24 0.001 0.077 0.0
0.001 0.115 0.94
Pass
25 0.009 0.090 9.9
0.009 0.135 6.70
Pass
26 0.001 0.071 0.0
0.001 0.106 0.98
Pass
27 0.008 0.083 9.3
0.008 0.125 6.26
Pass
28 0.001 0.066 0.0
0.001 0.099 1.05
Pass
29 0.007 0.078 8.6
0.007 0.116 5.92
Pass
30 0.001 0.061 0.0
0.001 0.092 1.21
Pass
31 0.006 0.073 8.1
0.006 0.109 5.52
Pass
32 0.001 0.058 0.0
0.001 0.086 1.19
Pass
33 0.005 0.068 7.5
0.005 0.102 5.18
Pass
34 0.001 0.054 0.0
0.001 0.081 1.22
Pass
35 0.005 0.064 0.0
0.005 0.096 4.85
Pass
36 0.000 0.051 0.0
0.001 0.077 1.23
Pass
37 0.004 0.061 0.0
0.004 0.091 4.61
Pass
38 0.000 0.048 0.0
0.001 0.073 1.23
Pass
39 0.004 0.058 0.0
0.004 0.087 4.30
Pass
40 0.000 0.046 0.0
0.001 0.069 1.24
Pass
Ident. Nr.:
111931
Date:
2008-09-09
111931 EMC TRF_verified
page 23 of 50
Voltage Source Verification Data (Run time)
EUT: jbl-on stage-200iD
Tested by: Test Operator
Start time: 4:56:05 PM
End time: 4:58:56 PM
Test duration (min): 2.5
Data file name: H-000232.cts_data
Comment: Connect to PC
Customer: Customer
Test Result: Pass Source qualification: Normal
Highest parameter values during test:
Customer: Customer
Test Result: Pass Source qualification: Normal
Highest parameter values during test:
Voltage (Vrms): 230.07
Frequency(Hz): 50.00
I_Peak (Amps): 0.440
I_RMS (Amps): 0.080
I_Fund (Amps): 0.031
Crest Factor:
5.907
Power (Watts): 6.5
Power Factor:
0.356
Harm# Harmonics
V-rms Limit
V-rms %
of
Limit Status
2
0.120
0.460
26.06
OK
3
0.455
2.071
21.98
OK
4
0.111
0.460
24.12
OK
5
0.024
0.920
2.56
OK
6
0.059
0.460
12.72
OK
7
0.041
0.690
5.88
OK
8
0.023
0.460
4.98
OK
9
0.029
0.460
6.32
OK
10
0.033
0.460
7.23
OK
11
0.024
0.230
10.39
OK
12
0.016
0.230
6.80
OK
13
0.007
0.230
3.23
OK
14
0.014
0.230
6.03
OK
15
0.020
0.230
8.56
OK
16
0.016
0.230
6.93
OK
17
0.009
0.230
3.72
OK
18
0.014
0.230
6.28
OK
19
0.019
0.230
8.42
OK
20
0.017
0.230
7.35
OK
21
0.011
0.230
4.71
OK
22
0.008
0.230
3.52
OK
23
0.016
0.230
6.77
OK
24
0.005
0.230
2.34
OK
25
0.013
0.230
5.57
OK
26
0.009
0.230
3.79
OK
27
0.012
0.230
5.13
OK
28
0.008
0.230
3.40
OK
29
0.013
0.230
5.82
OK
30
0.008
0.230
3.41
OK
31
0.009
0.230
3.75
OK
32
0.008
0.230
3.53
OK
33
0.012
0.230
5.43
OK
34
0.005
0.230
2.15
OK
35
0.007
0.230
3.00
OK
36
0.005
0.230
2.31
OK
37
0.011
0.230
4.59
OK
38
0.003
0.230
1.42
OK
39
0.006
0.230
2.48
OK
40
0.011
0.230
4.70
OK
Ident. Nr.:
111931
Date:
2008-09-09
111931 EMC TRF_verified
page 24 of 50
6.6.2 Table 010
Harmonics – Class-A per Ed. 3.0 (2006)(Run time)
EUT: jbl on stage-200iD
Tested by: Test Operator
Start time: 5:29:40 PM
End time: 5:32:31 PM
Test duration (min): 2.5
Data file name: H-000235.cts_data
Comment: Connect to ipod and play
Customer: Customer
Test Result: Pass Source qualification: Normal
Current & voltage waveforms
Customer: Customer
Test Result: Pass Source qualification: Normal
Current & voltage waveforms
-0.6
-0.4
-0.2
0.0
0.2
0.4
0.6
-300
-200
-100
0
100
200
300
Current (Amps)
Voltage (Volts)
Limits
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Current RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
Test result: Pass Worst harmonic was #19 with 8.44% of the limit.