EMC - CB Certificate
Brand
Device
Audio
File
on-stage-200id-sm2.pdf
Date

JBL ON STAGE 200ID (serv.man2) EMC - CB Certificate ▷ View online

Ident. Nr.: 
111931 
Date:  
2008-09-09 
 
111931 EMC TRF_verified 
page 29 of 50 
Electrostatic discharge, ESD 
8.1 Standard 
Basic standard 
EN 61000-4-2:1995/A11998/A22001 
Date of testing 
2008-09-02 
Performance criteria: 
8.2 Measurement equipment 
 
Equipment 
Last Calibration 
Type 
 
Serial No
.  
Manufacturer 
  ESD tester  
September 26, 2007 
ESD 30C 
SB4076 
EMTEST  
8.3 Test set-up 
See annex B 
The EUT shall be exposed to at least 200 discharges , 100 each at negative and positive polarity ,at a 
min of four test points (a min of 50 discharges at each point),One of the test points shall be subjected 
to at least 50 indirect discharges(contact) to the centre of the front edge of the hori coupling plane,The 
remaining three points shall each receive at least 50 direct contact discharges. If no direct contact test 
points are available,then at least 200 indirect discharges shall be applied in the indirect mode.Test shall 
be performed at a max repetition of one discharge per second. 
On those parts of the EUT where it is not possible to perform contact discharge testing ,the equipment 
should be investigated to identify user accessible points where breakdown may occur; A min of 10 
single air discharges shall be applied to the selected test point for each such area. 
 
Direct application of discharges to the EUT: 
Contact discharge was applied only to conductive surfaces of the EUT. 
Air discharges were applied only to non-conductive surfaces of the EUT. 
During the test, it was performed with single discharges. For the single discharge time between 
successive single discharges will be keep longer 1 second. It was at least ten single discharges with 
positive and negative at the same selected point. 
 
Indirect application of discharges to the EUT: 
Vertical Coupling Plane (VCP): 
The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and positioned at a distance 0.1m 
from, the EUT, with the Discharge Electrode touching the coupling plane. 
The four faces of the EUT will be performed with electrostatic discharge. It was at least ten single 
discharges with positive and negative at the same selected point. 
Horizontal Coupling Plane (HCP): 
The coupling plane is placed under to the EUT. The generator shall be positioned vertically at a 
distance of 0.1m from the EUT, with the Discharge Electrode touching the coupling plane. 
The four faces of the EUT will be performed with electrostatic discharge. It was at least ten single 
discharges with positive and negative at the same selected point. 
 
 
 
 
 
 
 
 
 
Ident. Nr.: 
111931 
Date:  
2008-09-09 
 
111931 EMC TRF_verified 
page 30 of 50 
8.4 Test results 
Mode 
Table 
Remarks 
Result 
TM1 
&TM2  
013 Air 
discharge:±8KV 
Contact discharge:±4KV 
Pass   
8.5 Tables 
8.5.1 Table 013 
 
 
 
 
 
 
 
 
 
 
 
Location 
Discharge 
Method 
Test Voltage 
Amount of 
test points 
Result 
HCP 
[Horizontal Coupling Plane] 
Indirect Contact
±2,4kV 
4 Pass 
VCP 
[Vertical Coupling Plane] 
Indirect Contact
±2,4kV 
4 Pass 
Button 
Indirect Contact
±2,4kV 
2 Pass 
Metal enclosure of IPOD groove 
Indirect Contact
±2,4kV 
1 Pass 
Nonconductive Enclosure of speaker 
Air 
±2,4,6,8kV 
6 Pass 
Nonconductive Enclosure of infrared  
Remote controller 
Air 
±2,4,6,8kV 
4 Pass 
Ident. Nr.: 
111931 
Date:  
2008-09-09 
 
111931 EMC TRF_verified 
page 31 of 50 
 
9 Radiated 
Immunity 
9.1 Standard 
Basic standard 
EN 61000-4-3:2006 
Date of testing 
2008-09-02 
Performance criteria: 
9.2 Measurement equipment 
 
Equipment 
Last Calibration
Type 
 
Serial No
.  
Manufacturer 
  Signal Generator
 
January 25, 
2008 
SMT03
 
SB3433
 
Rohde & Schwarz
 
  Anechoic chamber
 
January 25, 
2008 
MCDC
 
SB3450/02
 
Albatross Projects
 
  Voltage Probe
 
January 25, 
2008 
URV5-Z2
 
SB3437/02
 
Rohde & Schwarz
 
  Power Amplifier
 
January 25, 
2008 
150W1000
 
SB3173
 
AR
 
9.3 Test set-up 
See annex B  
The testing was performed in a fully anechoic chamber. The EUT and load, which are placed on a table 
that is 0.8 meter above ground, The transmit antenna was located at a distance of 3 meters from the 
EUT. The frequency range is swept from 80 MHz to 1000MHz with the signal 80% amplitude 
modulated with a 1 kHz sine wave. The rate of sweep did not exceed 1.5×10-3 decade/s. The step size 
was 1% of fundamental.  The dwell time at each frequency shall be not less than the time necessary for 
the EUT to be able to respond.  The field strength level was 3V/m.  The test was performed with the 
EUT exposed to both vertically and horizontally polarized fields on each of the four sides. 
9.4 Test results 
Mode 
Table 
Remarks 
Result 
TM1 
&TM2 
014 
1. Field Strength :3 V/m (r.m.s unmodulated) 
2. Radiated Signal: AM 80% Modulated with 1kHz 
3. Scanning Frequency :80MHz - 1000MHz 
4. Dwell Time: 1 Seconds 
5. Frequency steps : 1% 
6. Enclosure port 
Pass   
 
Ident. Nr.: 
111931 
Date:  
2008-09-09 
 
111931 EMC TRF_verified 
page 32 of 50 
 
9.5 Table 
9.5.1 Table 014 
 
 
Frequency Range 
(MHz) 
 
80-1000MHz 
Field Strength 
(V/m) 
3V/m  1kHz 80%AM 
Steps  
(%) 
1% 
Dwell time 
1 s 
Polarization 
Horizontal 
Vertical 
Front Pass 
Pass 
Rear Pass 
Pass 
Left Pass 
Pass 
Right Pass 
Pass 
 
 