JBL ON STAGE 200ID (serv.man2) EMC - CB Certificate ▷ View online
Ident. Nr.:
111931
Date:
2008-09-09
111931 EMC TRF_verified
page 25 of 50
Current Test Result Summary (Run time)
EUT: jbl-on stage-200iD
Tested by: Test Operator
Start time: 5:29:40 PM
End time: 5:32:31 PM
Test duration (min): 2.5
Data file name: H-000235.cts_data
Comment: Connect to ipod and play
Customer: Customer
Test Result: Pass Source qualification: Normal
THC(A): 0.04 I-THD(%): 219.88 POHC(A): 0.017 POHC Limit(A): 0.271
Highest parameter values during test:
Customer: Customer
Test Result: Pass Source qualification: Normal
THC(A): 0.04 I-THD(%): 219.88 POHC(A): 0.017 POHC Limit(A): 0.271
Highest parameter values during test:
V_RMS (Volts): 230.07
Frequency(Hz): 50.00
I_Peak (Amps): 0.491
I_RMS (Amps): 0.090
I_Fund (Amps): 0.032
Crest Factor:
7.289
Power (Watts): 6.7
Power Factor:
0.358
Harm# Harms(avg) 100%Limit %of
Limit Harms(max) 150%Limit %of
Limit Status
2 0.002 1.080 0.0
0.003 1.620 0.16
Pass
3 0.016 2.300 0.7
0.030 3.450 0.86
Pass
4 0.001 0.430 0.0
0.002 0.645 0.34
Pass
5 0.016 1.140 1.4
0.028 1.710 1.63
Pass
6 0.001 0.300 0.0
0.001 0.450 0.31
Pass
7 0.015 0.770 2.0
0.026 1.155 2.29
Pass
8 0.001 0.230 0.0
0.002 0.345 0.49
Pass
9 0.015 0.400 3.6
0.025 0.600 4.12
Pass
10 0.001 0.184 0.0
0.001 0.276 0.53
Pass
11 0.014 0.330 4.2
0.023 0.495 4.58
Pass
12 0.001 0.153 0.0
0.002 0.230 0.66
Pass
13 0.013 0.210 6.1
0.020 0.315 6.49
Pass
14 0.001 0.131 0.0
0.001 0.197 0.75
Pass
15 0.012 0.150 8.0
0.018 0.225 8.10
Pass
16 0.001 0.115 0.0
0.001 0.173 0.86
Pass
17 0.011 0.132 8.3
0.016 0.199 8.07
Pass
18 0.001 0.102 0.0
0.001 0.153 0.98
Pass
19 0.010 0.118 8.4
0.014 0.178 7.86
Pass
20 0.001 0.092 0.0
0.001 0.138 1.05
Pass
21 0.009 0.107 8.4
0.012 0.161 7.51
Pass
22 0.001 0.084 0.0
0.001 0.125 1.15
Pass
23 0.008 0.098 8.3
0.010 0.147 7.10
Pass
24 0.001 0.077 0.0
0.001 0.115 1.18
Pass
25 0.007 0.090 8.0
0.009 0.135 6.68
Pass
26 0.001 0.071 0.0
0.001 0.106 1.24
Pass
27 0.006 0.083 7.7
0.008 0.125 6.28
Pass
28 0.001 0.066 0.0
0.001 0.099 1.24
Pass
29 0.006 0.078 7.3
0.007 0.116 5.92
Pass
30 0.001 0.061 0.0
0.001 0.092 1.37
Pass
31 0.005 0.073 6.9
0.006 0.109 5.55
Pass
32 0.001 0.058 0.0
0.001 0.086 1.31
Pass
33 0.004 0.068 6.5
0.005 0.102 5.26
Pass
34 0.001 0.054 0.0
0.001 0.081 1.29
Pass
35 0.004 0.064 0.0
0.005 0.096 4.99
Pass
36 0.001 0.051 0.0
0.001 0.077 1.28
Pass
37 0.003 0.061 0.0
0.004 0.091 4.73
Pass
38 0.001 0.048 0.0
0.001 0.073 1.26
Pass
39 0.003 0.058 0.0
0.004 0.087 4.46
Pass
40 0.000 0.046 0.0
0.001 0.069 1.24
Pass
Ident. Nr.:
111931
Date:
2008-09-09
111931 EMC TRF_verified
page 26 of 50
Voltage Source Verification Data (Run time)
EUT: jbl-on stage-200iD
Tested by: Test Operator
Start time: 5:29:40 PM
End time: 5:32:31 PM
Test duration (min): 2.5
Data file name: H-000235.cts_data
Comment: Connect to ipod and play
Customer: Customer
Test Result: Pass Source qualification: Normal
Highest parameter values during test:
Customer: Customer
Test Result: Pass Source qualification: Normal
Highest parameter values during test:
Voltage (Vrms): 230.07
Frequency(Hz): 50.00
I_Peak (Amps): 0.491
I_RMS (Amps): 0.090
I_Fund (Amps): 0.032
Crest Factor:
7.289
Power (Watts): 6.7
Power Factor:
0.358
Harm# Harmonics
V-rms Limit
V-rms %
of
Limit Status
2
0.129
0.460
27.97
OK
3
0.454
2.070
21.93
OK
4
0.104
0.460
22.52
OK
5
0.024
0.920
2.63
OK
6
0.073
0.460
15.77
OK
7
0.035
0.690
5.05
OK
8
0.031
0.460
6.77
OK
9
0.027
0.460
5.78
OK
10
0.025
0.460
5.33
OK
11
0.021
0.230
9.13
OK
12
0.017
0.230
7.59
OK
13
0.010
0.230
4.53
OK
14
0.010
0.230
4.28
OK
15
0.018
0.230
7.81
OK
16
0.016
0.230
6.99
OK
17
0.007
0.230
3.01
OK
18
0.014
0.230
6.03
OK
19
0.017
0.230
7.37
OK
20
0.019
0.230
8.04
OK
21
0.011
0.230
4.57
OK
22
0.008
0.230
3.61
OK
23
0.015
0.230
6.37
OK
24
0.006
0.230
2.53
OK
25
0.012
0.230
5.28
OK
26
0.011
0.230
4.72
OK
27
0.013
0.230
5.85
OK
28
0.007
0.230
2.97
OK
29
0.013
0.230
5.54
OK
30
0.007
0.230
3.26
OK
31
0.010
0.230
4.13
OK
32
0.006
0.230
2.69
OK
33
0.012
0.230
5.06
OK
34
0.004
0.230
1.77
OK
35
0.008
0.230
3.27
OK
36
0.004
0.230
1.77
OK
37
0.009
0.230
3.74
OK
38
0.005
0.230
2.05
OK
39
0.007
0.230
3.04
OK
40
0.010
0.230
4.30
OK
Ident. Nr.:
111931
Date:
2008-09-09
111931 EMC TRF_verified
page 27 of 50
7
Voltage fluctuations and flicker
7.1 Standard
Basic standard
EN 61000-3-3:1995+A1:2001+A2:2005
Date of testing
2008-09-02
7.2 Measurement equipment
Equipment
Last Calibration
Type
Serial No
.
Manufacturer
Power
February 20, 2008
5001ix-CTS-400
SB2588
CI
Three Phase
Harmonic flicker
test system
test system
February 20, 2008
PACS-3
SB2588/01
CI
Power
February 20, 2008
5001ix-CTS-400-NO SB2588/02
CI
Power
February 20, 2008
5001ix-CTS-400-NO SB2588/03
CI
7.3 Test set-up
See annex B
The following limits apply:
-
The following limits apply:
-
the value of Pst shall not be greater than 1.0;
-
the value of Plt shall not be greater than 0.65;
-
the value of d(t) during a voltage change shall not exceed 3.3 % for more than 500 ms;
-
the relative steady-state voltage change, dc, shall not exceed 3.3 %;
-
the maximum relative voltage change, dmax, shall not exceed;
a) 4 % without additional conditions;
b) 6 % for equipment which is:
-
b) 6 % for equipment which is:
-
switched manually, or
-
switched automatically more frequently than twice per day, and also has either a delayed restart (the
delay being not less than a few tens of seconds), or manual restart,after a power supply interruption.
Note:The cycling frequency will be further limited by the Pst and Plt limit. For example: a dmax of 6%
producing a rectangular voltage change characteristic twice per hour will give a P1t of about 0.65.
c) 7 % for equipment which is:
-
Note:The cycling frequency will be further limited by the Pst and Plt limit. For example: a dmax of 6%
producing a rectangular voltage change characteristic twice per hour will give a P1t of about 0.65.
c) 7 % for equipment which is:
-
attended whilst in use (for example: hair dryers, vacuum cleaners, kitchen equipment such as
mixers, garden equipment such as lawn mowers, portable tools such as electric drills), or
-
-
switched on automatically, or is intended to be switched on manually, no more than twice per day,
and also has either a delayed restart (the delay being not less than a few tens of seconds) or manual
restart, after a power supply interruption. Pst and Plt requirements shall not be applied to voltage
changes caused by manual switching.
restart, after a power supply interruption. Pst and Plt requirements shall not be applied to voltage
changes caused by manual switching.
7.4 Test results
Mode
Table
Remarks
Result
TM1
011
230VAC 50Hz
Pass **
TM2
012
230VAC 50Hz
Pass **
**)
There is no testing required if the device does not generate any significant voltage fluctuations or flicker.
(EN61000-3-3)
A short time measurement confirmed the assumption that this is the fact. The details in the test module
are representing the results of the short time measurement.
(EN61000-3-3)
A short time measurement confirmed the assumption that this is the fact. The details in the test module
are representing the results of the short time measurement.
Ident. Nr.:
111931
Date:
2008-09-09
111931 EMC TRF_verified
page 28 of 50
7.5 Table
7.5.1 Table 011
7.5.2 Table 012
TM1
EUT values
Limit
Result
Pst 0.064
1.00
PASS
dc [%]
0.00
3.30%
PASS
dmax [%]
0.00
4.00%
PASS
dt [s]
0.0
Not exceed 3.3% for 500ms
PASS
TM2
EUT values
Limit
Result
Pst 0.064
1.00
PASS
dc [%]
0.00
3.30%
PASS
dmax [%]
0.00
4.00%
PASS
dt [s]
0.0
Not exceed 3.3% for 500ms
PASS
Click on the first or last page to see other ON STAGE 200ID (serv.man2) service manuals if exist.