JBL EMC - CB Certificate (serv.man6) EMC - CB Certificate ▷ View online
Issue Date:
2014-08-11
Page 37 of 43
Report Reference #
BTL-CB-1-S1407C070
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
2.10.3 and
2.10.4
2.10.4
TABLE: Clearance and creepage distance measurements
P
Clearance (cl) and creepage
distance (cr) at/of/between:
distance (cr) at/of/between:
U peak
(V)
U r.m.s.
(V)
Required cl
(mm)
cl
(mm)
Required cr
(mm)
cr
(mm)
Functional:
-- --
--
--
--
--
--
Basic/Supplementary:
-- --
--
--
--
--
--
Reinforced:
-- --
--
--
--
--
--
Supplementary information:
2.10.5
TABLE: Distance through insulation measurements
N/A
Distance through insulation (DTI) at/of:
U peak
(V)
U rms
(V)
Test
voltage
(V)
Required DTI
(mm)
DTI
(mm)
Supplementary:
4.3.8 TABLE:
Batteries
P
The tests of 4.3.8 are applicable only when appropriate battery
data is not available
data is not available
See below
P
Is it possible to install the battery in a reverse polarity position?
See below
P
Non-rechargeable batteries
Rechargeable batteries
Discharging
Un-
intentional
charging
Charging
Discharging
Reversed
charging
Meas.
current
Manuf.
Specs.
Specs.
Meas.
current
Manuf.
Specs.
Specs.
Meas.
current
Manuf.
Specs.
Specs.
Meas.
current
Manuf.
Specs.
Specs.
Max.
current
during
normal
condition
current
during
normal
condition
-- --
Normal
reverse
current =
0mA
-- -- -- -- -- --
Max.
current
during
fault
condition
current
during
fault
condition
-- --
Abnormal
reverse
current =
0.38mA
(D1 pin 1 to
pin 2 short)
-- -- -- -- --
Issue Date:
2014-08-11
Page 38 of 43
Report Reference #
BTL-CB-1-S1407C070
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
Max.
current
during
fault
condition
current
during
fault
condition
-- --
Abnormal
reverse
current =
0mA (R10
short)
-- -- -- -- -- --
Supplementary information:
Test results:
Test results:
Verdict
- Chemical leaks
N/A
- Explosion of the battery
N/A
- Emission of flame or expulsion of molten metal
N/A
- Electric strength tests of equipment after completion of tests
N/A
Supplementary information:
4.3.8 TABLE:
Batteries
P
Battery category ........................................... : See table 1.5.1 for details
Manufacturer ................................................ : See table 1.5.1 for details
Type / model ................................................ : See table 1.5.1 for details
Voltage ......................................................... : 3V
Capacity ....................................................... : See table 1.5.1 for details
Tested and Certified by (incl. Ref. No.) ........ : --
Circuit protection diagram:
Manufacturer ................................................ : See table 1.5.1 for details
Type / model ................................................ : See table 1.5.1 for details
Voltage ......................................................... : 3V
Capacity ....................................................... : See table 1.5.1 for details
Tested and Certified by (incl. Ref. No.) ........ : --
Circuit protection diagram:
See below
MARKINGS AND INSTRUCTIONS (1.7.12, 1.7.15)
Remark: Correct subclause reference for IEC 60950-1:2005/A1 is 1.7.2.1, 1.7.13.
Remark: Correct subclause reference for IEC 60950-1:2005/A1 is 1.7.2.1, 1.7.13.
Location of replaceable battery
BAT1
Language(s) …………………………………….: English
Close to the battery …………………………….: N/A
In the servicing instructions ……………………: Complied
In the operating instructions …………………..:
N/A
4.5
TABLE: Thermal requirements
P
Supply
voltage (V) .......................... :
13Vdc --
Ambient T
min
(
C) ............................ :
See
below
Shift to
40
C
-- --
Ambient T
max
(
C) ............................ :
-- -- -- --
Maximum measured temperature T of part/at::
T (
C)
Allowed
T
max
(
C)
01. DC jack
32.8 44.9 --
-- --
Issue Date:
2014-08-11
Page 39 of 43
Report Reference #
BTL-CB-1-S1407C070
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
02. PWB near U4
46.5 58.6 --
-- 105
03. PWB near U5
43.4 55.5 --
-- 105
04. L11 body
53.9 66.0 --
-- 105
05. CE6 body
53.9 66.0 --
-- 85
06. PWB near U18
57.9 70.0 --
-- 105
07. BAT1 body
29.6 41.7 --
-- --
08. Inside enclosure near U18
42.4 54.5 --
-- --
09. Outside enclosure near U18
32.1 44.2 --
-- 95
10. Panel
31.1 43.2 --
-- 95
11. Ambient
27.9 40.0 --
-- --
Supplementary information:
1. The temperatures were measured under the worst case of normal mode defined in sub-clause 1.2.2.1
1. The temperatures were measured under the worst case of normal mode defined in sub-clause 1.2.2.1
and as described in sub-clause 1.6.2 at voltages as described above.
2. With a specified ambient temperature of + 40 °C. Therefore the maximum temperatures measured
are recalculated as follows: T + (40 – T
amb
), where T is the maximum temperature measured during
test and Tamb is the ambient temperature during the test.
Temperature T of winding:
t
1
(°C)
R
1
(
)
t
2
(°C)
R
2
(
)
T (
C)
Allowed
T
max
(
C)
Insulatio
n class
Supplementary information:
4.5.5
TABLE: Ball pressure test of thermoplastic parts
N/A
Allowed impression diameter (mm) ..................... :
2 mm
Part
Test temperature
(
C)
Impression
diameter (mm)
Supplementary information:
4.7
TABLE: Resistance to fire
P
Part
Manufacturer of
material
Type of material
Thickness
(mm)
Flammability
class
Evidence
PWB 1) 1)
--
V-1
min
1)
Supplementary information:
1)
1)
See appended table 1.5.1
5.1
TABLE: touch current measurement
N/A
Issue Date:
2014-08-11
Page 40 of 43
Report Reference #
BTL-CB-1-S1407C070
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
Measured between:
Measured
(mA)
Limit
(mA)
Comments/conditions
supplementary information:
Input voltage:
Input frequency:
Overall capacity:
5.2
TABLE: Electric strength tests, impulse tests and voltage surge tests
N/A
Test voltage applied between:
Voltage shape
(AC, DC,
impulse, surge)
Test voltage (V) Breakdow
n
Yes / No
Functional:
Basic/supplementary:
Reinforced:
Supplementary information:
5.3
TABLE: Fault condition tests
P
Ambient temperature (
C) ................................ See below
Power source for EUT: Manufacturer,
model/type, output rating ..................................
model/type, output rating ..................................
See appended table 1.5.1 for
details
details
Component
No.
Fault
Supply
voltage
(V)
Test
time
Fuse #
Fuse
current
(A)
Observation
1. U18 pin28 to
pin13
pin13
Short -
circuit
13 Vdc 10 mins
--
--
Unit operated normally except
speaker no output, no damaged,
no hazards.
speaker no output, no damaged,
no hazards.
2. U18 pin28 to
pin14
pin14
Short -
circuit
13 Vdc
10 mins
--
--
Unit operated normally except
speaker no output, no damaged,
no hazards.
speaker no output, no damaged,
no hazards.