Issue Date: 
2014-08-11 
Page 10 of 20 
Report Reference #
BTL-CB-1-S1407C070
 
 
 
 
 
IEC60950_1F - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
 
 
 
 
 
IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
 
Clause 
Requirement + Test 
Result - Remark 
Verdict
Bibliograph
Additional EN standards. 
Added. 
 
 
 
 
 
ZA 
NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH 
THEIR CORRESPONDING EUROPEAN PUBLICATIONS 
 
 
ZB ANNEX (normative) 
SPECIAL NATIONAL CONDITIONS (EN) 
Clause 
Requirement + Test 
Result - Remark 
Verdict
1.2.4.1 
In Denmark, certain types of Class I appliances 
(see 3.2.1.1) may be provided with a plug not 
establishing earthing conditions when inserted into 
Danish socket-outlets. 
No power supply cord 
provided. 
N/A 
1.2.13.14 
(A11:2009) 
In Norway and Sweden, for requirements see 
1.7.2.1 and 7.3 of this annex. 
The equipment is not 
connected to the cable 
distribution systems. 
N/A 
1.5.7.1 
(A11:2009)
 
In Finland, Norway and Sweden, resistors 
bridging 
BASIC INSULATION 
in 
CLASS I PLUGGABLE 
EQUIPMENT TYPE A 
must comply with the 
requirements in 1.5.7.1. In addition when a single 
resistor is used, the resistor must withstand the 
resistor test in 1.5.7.2. 
No such resistors. 
N/A 
1.5.8 
In Norway, due to the IT power system used (see 
annex V, Figure V.7), capacitors are required to be 
rated for the applicable line-to-line voltage (230 V).
 N/A 
1.5.9.4 
In FinlandNorway and Sweden, the third dashed 
sentence is applicable only to equipment as 
defined in 6.1.2.2 of this annex. 
No TNV circuit within the 
equipment. 
N/A 
Issue Date: 
2014-08-11 
Page 11 of 20 
Report Reference #
BTL-CB-1-S1407C070
 
 
 
 
 
IEC60950_1F - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
 
 
 
 
 
ZB ANNEX (normative) 
SPECIAL NATIONAL CONDITIONS (EN) 
Clause 
Requirement + Test 
Result - Remark 
Verdict
1.7.2.1 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.7.2.1 
(A11:2009)
 
In FinlandNorway and Sweden, CLASS I 
PLUGGABLE EQUIPMENT TYPE A intended for 
connection to other equipment or a network shall, if 
safety relies on connection to protective earth or if 
surge suppressors are connected between the 
network terminals and accessible parts, have a 
marking stating that the equipment must be 
connected to an earthed mains socket-outlet. 
The marking text in the applicable countries shall 
be as follows: 
In Finland: "Laite on liitettävä suojakoskettimilla 
varustettuun pistorasiaan" 
In Norway: “Apparatet må tilkoples jordet 
stikkontakt” 
In Sweden: “Apparaten skall anslutas till jordat 
uttag” 
 
In Norway and Sweden, the screen of the cable 
distribution system is normally not earthed at the 
entrance of the building and there is normally no 
equipotential bonding system within the building. 
Therefore the protective earthing of the building 
installation need to be isolated from the screen of a 
cable distribution system.  
It is however accepted to provide the insulation 
external to the equipment by an adapter or an 
interconnection cable with galvanic isolator, which 
may be provided by e.g. a retailer. 
The user manual shall then have the following or 
similar information in Norwegian and Swedish 
language respectively, depending on in what 
country the equipment is intended to be used in: 
“Equipment connected to the protective earthing of 
the building installation through the mains 
connection or through other equipment with a 
connection to protective earthing – and to a cable 
distribution system using coaxial cable, may in 
some circumstances create a fire hazard. 
Connection to a cable distribution system has 
therefore to be provided through a device providing 
electrical isolation below a certain frequency range 
(galvanic isolator, see EN 60728-11).” 
 
 N/A 
Issue Date: 
2014-08-11 
Page 12 of 20 
Report Reference #
BTL-CB-1-S1407C070
 
 
 
 
 
IEC60950_1F - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
 
 
 
 
 
ZB ANNEX (normative) 
SPECIAL NATIONAL CONDITIONS (EN) 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
NOTE In Norway, due to regulation for installations of cable 
distribution systems, and in Sweden, a galvanic isolator shall 
provide electrical insulation below 5 MHz. The insulation shall 
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz, 
for 1 min.
 
Translation to Norwegian (the Swedish text will 
also be accepted in Norway): 
“Utstyr som er koplet til beskyttelsesjord via 
nettplugg og/eller via annet jordtilkoplet 
utstyr – og er tilkoplet et kabel-TV nett, kan 
forårsake brannfare. For å unngå dette skal det 
ved tilkopling av utstyret til kabel-TV nettet 
installeres en galvanisk isolator mellom utstyret og 
kabel- TV nettet.” 
Translation to Swedish: 
”Utrustning som är kopplad till skyddsjord via jordat 
vägguttag och/eller via annan 
utrustning och samtidigt är kopplad till kabel-TV 
nät kan i vissa fall medfőra risk főr 
brand. Főr att undvika detta skall vid anslutning av 
utrustningen till kabel-TV nät 
galvanisk isolator finnas mellan utrustningen och 
kabel-TV nätet.” 
 
N/A 
1.7.2.1 
(A2:2013)
 
In Denmark, CLASS I PLUGGABLE EQUIPMENT 
TYPE A intended for connection to other 
equipment or a network shall, if safety relies on 
connection to protective earth or if surge 
suppressors are connected between the network 
terminals and accessible parts, have a marking 
stating that the equipment must be connected to 
an earthed mains socket-outlet. 
The marking text in Denmark shall be as follows: 
In Denmark: “Apparatets stikprop skal tilsluttes en 
stikkontakt med jord, som giver forbindelse til 
stikproppens jord.” 
 N/A 
1.7.5 
 
 
 
 
 
 
 
1.7.5 
(A11:2009)
 
In Denmark, socket-outlets for providing power to 
other equipment shall be in accordance with the 
Heavy Current Regulations, Section 107-2-D1, 
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, 
when used on Class I equipment. For 
STATIONARY EQUIPMENT the socket-outlet shall 
be in accordance with Standard Sheet DK 1-1b or 
DK 1-5a. 
For 
CLASS II EQUIPMENT
 
the socket outlet shall be in 
accordance with Standard Sheet DKA 1-4a. 
No socket-outlets provided. 
N/A 
Issue Date: 
2014-08-11 
Page 13 of 20 
Report Reference #
BTL-CB-1-S1407C070
 
 
 
 
 
IEC60950_1F - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
 
 
 
 
 
ZB ANNEX (normative) 
SPECIAL NATIONAL CONDITIONS (EN) 
Clause 
Requirement + Test 
Result - Remark 
Verdict
1.7.5 
(A2:2013)
 
In Denmark, socket-outlets for providing power to 
other equipment shall be in accordance with the 
DS 60884-2-D1:2011. 
For class I equipment the following Standard 
Sheets are applicable: DK 1-3a, DK 1-1c,  
DK 1-1d, DK 1-5a or DK 1-7a, with the exception 
for STATIONARY EQUIPMENT where the socket-
outlets shall be in accordance with Standard Sheet 
DK 1-1b, DK 1-1c, DK 1-1d or DK 1-5a. 
Socket outlets intended for providing power to 
Class II apparatus with a rated current of 2,5 A 
shall be in accordance with DS 60884-2-D1 
standard sheet DKA 1-4a. Other current rating 
socket outlets shall be in compliance with by DS 
60884-2-D1 Standard Sheet DKA 1-3a or DKA 1-
3b. 
Justification 
the Heavy Current Regulations, 6c 
 N/A 
2.2.4 
In Norway, for requirements see 1.7.2.1, 6.1.2.1 
and 6.1.2.2 of this annex. 
No TNV circuits within the 
equipment. 
N/A 
2.3.2 
In FinlandNorway and Sweden there are 
additional requirements for the insulation. See 
6.1.2.1 and 6.1.2.2 of this annex. 
No TNV circuits within the 
equipment. 
N/A 
2.3.4 
In Norway, for requirements see 1.7.2.1, 6.1.2.1 
and 6.1.2.2 of this annex. 
No TNV circuits within the 
equipment. 
N/A 
2.6.3.3 
In the United Kingdom, the current rating of the 
circuit shall be taken as 13 A, not 16 A. 
 N/A 
2.7.1 
In the United Kingdom, to protect against 
excessive currents and short-circuits in the 
PRIMARY CIRCUIT of DIRECT PLUG-IN 
EQUIPMENT, tests according to 5.3 shall be 
conducted, using an external protective device 
rated 30 A or 32 A. If these tests fail, suitable 
protective devices shall be included as integral 
parts of the DIRECT PLUG-IN EQUIPMENT, so 
that the requirements of 5.3 are met. 
The equipment is not direct 
plug-in equipment. 
N/A 
2.10.5.13 
In FinlandNorway and Sweden, there are 
additional requirements for the insulation, see 
6.1.2.1 and 6.1.2.2 of this annex. 
No TNV circuits within the 
equipment. 
N/A 