JBL EMC - CB Certificate (serv.man6) EMC - CB Certificate ▷ View online
Issue Date:
2014-08-11
Page 1 of 43
Report Reference #
BTL-CB-1-S1407C070
TRF No. IEC60950_1F
Test Report issued under the responsibility of:
TEST REPORT
IEC 60950-1
Information technology equipment – Safety –
Part 1: General requirements
Report Number. .............................. :
BTL-CB-1-S1407C070
Date of issue ................................... :
2014-08-12
Total number of pages ...................
43
Applicant’s name ........................... : HARMAN INTERNATIONAL INDUSTRIES, INC
Address ........................................... :
8500 BALBOA BLVD NORTHRIDGE CA 91329 UNITED STATES
Test specification:
Standard .......................................... :
IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013
Test procedure ............................... :
CB Scheme
Non-standard test method ............ : N/A
Test Report Form No. .................... : IEC60950_1F
Test Report Form(s) Originator .... : SGS Fimko Ltd
Master TRF ...................................... :
Dated 2014-02
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting
from the reader's interpretation of the reproduced material due to its placement and context.
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting
from the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the
CB Scheme procedure shall be removed.
CB Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory
and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing
Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB,
responsible for this Test Report.
This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing
Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB,
responsible for this Test Report.
Issue Date:
2014-08-11
Page 2 of 43
Report Reference #
BTL-CB-1-S1407C070
TRF No. IEC60950_1F
Test item description ....................... : Bluetooth Speaker
Trade Mark ........................................ : JBL
Manufacturer .................................... :
HARMAN INTERNATIONAL INDUSTRIES, INC
8500 BALBOA BLVD NORTHRIDGE CA 91329 UNITED STATES
Model/Type reference ...................... :
JBL HORIZON
Ratings .............................................. :
Input: 13Vdc, 2.2A
Testing procedure and testing location:
CB Testing Laboratory:
BTL Inc.
Testing location/ address ............................. : B1, No. 37, Lane 365, YangGuang St., NeiHu District
114, Taipei, Chinese Taipei
Associated CB Testing Laboratory:
Testing location/ address ............................. :
Tested by (name + signature) ...................... : Steven Chou
Approved by (name + signature) ................. : Jackie Chiu
Testing procedure: TMP/CTF Stage 1:
Testing location/ address ............................. :
Tested by (name + signature) ...................... :
Approved by (name + signature) ................. :
Testing procedure: WMT/CTF Stage 2:
Testing location/ address ............................. :
Tested by (name + signature) ...................... :
Witnessed by (name + signature) ................ :
Approved by (name + signature) ................. :
Testing procedure:
SMT/CTF Stage 3 or 4:
SMT/CTF Stage 3 or 4:
Testing location/ address ............................. :
Tested by (name + signature) ...................... :
Witnessed by (name + signature) ................ :
Approved by (name + signature) ................. :
Supervised by (name + signature) .............. :
Issue Date:
2014-08-11
Page 3 of 43
Report Reference #
BTL-CB-1-S1407C070
TRF No. IEC60950_1F
List of Attachments (including a total number of pages in each attachment):
- European Group difference and nation differences (20 pages)
- US differences (6 pages)
- Additional National differences according to IEC 60950-1 2ed.+A1:
- European Group difference and nation differences (20 pages)
- US differences (6 pages)
- Additional National differences according to IEC 60950-1 2ed.+A1:
- Additional National differences according to IEC 60950-1 2ed.:
- China differences (8 pages)
- Germany differences (1 page)
- Israel differences (3 pages)
- Korea differences (1 page)
- Germany differences (1 page)
- Israel differences (3 pages)
- Korea differences (1 page)
- Additional National differences according to IEC 60950-1 1ed.:
- Japan differences (10 pages)
- Miscellaneous documentation (1 pages)
- Photos documentation (8 pages)
Summary of testing:
Unless otherwise indicated, all tests were conducted at BTL Inc. B1, No. 37, Lane 365, YangGuang St.,
NeiHu District 114, Taipei, Chinese Taipei.
NeiHu District 114, Taipei, Chinese Taipei.
Tests performed (name of test and test clause):
Testing location:
Input: Single-Phase (1.6.2)
See above.
Durability Of Marking (1.7.11)
Limited Power Source Measurements (2.5)
Lithium Battery Reverse Current Measurement
(4.3.8)
(4.3.8)
Heating (4.5.1, 1.4.12, 1.4.13)
Abnormal Operation (5.3.1 - 5.3.9)
Issue Date:
2014-08-11
Page 4 of 43
Report Reference #
BTL-CB-1-S1407C070
TRF No. IEC60950_1F
Summary of compliance with National Differences
1)
The product fulfils the requirements of EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013.
EU Group Differences, US.
2)
For IEC 60950-1:2005+A1:2009
EU Group Differences, EU Special National Conditions, CA, DE, IL, KR.
3)
For IEC 60950-1:2005
AU, CA, CH, CN, DE, DK, ES, FI, GB, IE, IL, KR, NO, SE, US.
4)
For IEC 60950-1:2001
AR, AU, AT, BE, CA, CH, CN, CZ, DE, DK, ES, FI, FR, GB, GR, HU, IE, IL, IN, IT, JP, KE, KR,
MY, NL, NO, PL, SE, SG, SI, SK, US
MY, NL, NO, PL, SE, SG, SI, SK, US
Explanation of used codes: AR=Argentina, AT=Austria, AU=Australia, BE=Belgium, CA=Canada,
CH=Switzerland, CN=China, CZ=Czech Republic, DE=Germany, DK=Denmark, ES=Spain, FI=Finland,
FR=France, GB=United Kingdom, GR=Greece, HU=Hungary, IE=Ireland, IL=Israel, IN=India, IT=Italy,
JP=Japan, KE=Kenya, KR=Republic of Korea, MY=Malaysia, NL=The Netherlands, NO=Norway,
PL=Poland, SE=Sweden, SG=Singapore, SI=Slovenia, SK=Slovakia, US=United States of America.
CH=Switzerland, CN=China, CZ=Czech Republic, DE=Germany, DK=Denmark, ES=Spain, FI=Finland,
FR=France, GB=United Kingdom, GR=Greece, HU=Hungary, IE=Ireland, IL=Israel, IN=India, IT=Italy,
JP=Japan, KE=Kenya, KR=Republic of Korea, MY=Malaysia, NL=The Netherlands, NO=Norway,
PL=Poland, SE=Sweden, SG=Singapore, SI=Slovenia, SK=Slovakia, US=United States of America.
For National Differences see corresponding Attachment.