DOWNLOAD JBL EMC - CB Certificate (serv.man6) Service Manual ↓ Size: 2.22 MB | Pages: 127 in PDF or view online for FREE

Model
EMC - CB Certificate (serv.man6)
Pages
127
Size
2.22 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
emc-cb-certificate-sm6.pdf
Date

JBL EMC - CB Certificate (serv.man6) EMC - CB Certificate ▷ View online

Issue Date: 
2014-08-11 
Page 6 of 20 
Report Reference #
BTL-CB-1-S1407C070
 
 
 
 
 
IEC60950_1F - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
 
 
 
 
 
IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
Zx.3 Warning 
The warning shall be placed on the equipment, or 
on the packaging, or in the instruction manual and 
shall consist of the following: 
the symbol of Figure 1 with a minimum height of 
  5 mm; and 
the following wording, or similar: 
 
“To prevent possible hearing damage, do not listen 
at high volume levels for long periods.” 
 
 
 
 
 
Figure 1 – Warning label (IEC 60417-6044) 
 
Alternatively, the entire warning may be given 
through the equipment display during use, when 
the user is asked to acknowledge activation of the 
higher level. 
 
N/A 
 
Zx.4 Requirements for listening devices (headphones and earphones)
 
N/A 
 
Zx.4.1 Wired listening devices with analogue 
input 
With 94 dBA sound pressure output L
Aeq,T
, the 
input voltage of the fixed “programme simulation 
noise” described in EN 50332-2 shall be ≥ 75 mV. 
 
This requirement is applicable in any mode where 
the headphones can operate (active or 
passive), including any available setting (for 
example built-in volume level control). 
 
NOTE The values of 94 dBA – 75 mV correspond with 85dBA – 
27 mV and 100 dBA – 150 mV.
 
 
N/A 
Issue Date: 
2014-08-11 
Page 7 of 20 
Report Reference #
BTL-CB-1-S1407C070
 
 
 
 
 
IEC60950_1F - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
 
 
 
 
 
IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
Zx.4.2 Wired listening devices with digital input
With any playing device playing the fixed 
“programme simulation noise” described in EN 
50332-1 (and respecting the digital interface 
standards, where a digital interface standard exists 
that specifies the equivalent acoustic level), the 
acoustic output L
Aeq,T 
of the listening device shall 
be ≤ 100 dBA. 
 
This requirement is applicable in any mode where 
the headphones can operate, including any 
available setting (for example built-in volume level 
control, additional sound feature like equalization, 
etc.). 
 
NOTE An example of a wired listening device with digital input 
is a USB headphone.
 
 
N/A 
 
Zx.4.3 Wireless listening devices 
In wireless mode: 
with any playing and transmitting device playing 
  the fixed programme simulation noise described 
  in EN 50332-1; and 
respecting the wireless transmission standards, 
  where an air interface standard exists that 
  specifies the equivalent acoustic level; and 
with volume and sound settings in the listening 
  device (for example built-in volume level control, 
  additional sound feature like equalization, etc.) 
  set to the combination of positions that 
  maximize the measured acoustic output for the 
  abovementioned programme simulation noise, 
  the acoustic output L
Aeq,T 
of the listening device 
 shall be ≤ 100 dBA. 
 
NOTE An example of a wireless listening device is a Bluetooth 
headphone.
 
 
N/A 
 
Zx.5 Measurement methods 
Measurements shall be made in accordance with 
EN 50332-1 or EN 50332-2 as applicable.    
Unless stated otherwise, the time interval T shall 
be 30 s. 
 
NOTE Test method for wireless equipment provided without 
listening device should be defined.
 
 
N/A 
Issue Date: 
2014-08-11 
Page 8 of 20 
Report Reference #
BTL-CB-1-S1407C070
 
 
 
 
 
IEC60950_1F - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
 
 
 
 
 
IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
 
Clause 
Requirement + Test 
Result - Remark 
Verdict
2.7.1 
Replace the subclause as follows: 
Basic requirements 
To protect against excessive current, short-circuits 
and earth faults in PRIMARY CIRCUITS, protective 
devices shall be included either as integral parts of 
the equipment or as parts of the building 
installation, subject to the following, a), b) and c): 
a) except as detailed in b) and c), protective 
devices necessary to comply with the requirements 
of 5.3 shall be included as parts of the equipment;
b) for components in series with the mains input to 
the equipment such as the supply cord, appliance 
coupler, r.f.i. filter and switch, short-circuit and 
earth fault protection may be provided by 
protective devices in the building installation; 
Replaced.  
N/A 
 
c) it is permitted for PLUGGABLE EQUIPMENT 
TYPE B or PERMANENTLY CONNECTED 
EQUIPMENT, to rely on dedicated overcurrent and 
short-circuit protection in the building installation, 
provided that the means of protection, e.g. fuses or 
circuit breakers, is fully specified in the installation 
instructions. 
If reliance is placed on protection in the building 
installation, the installation instructions shall so 
state, except that for PLUGGABLE EQUIPMENT 
TYPE A the building installation shall be regarded 
as providing protection in accordance with the 
rating of the wall socket outlet. 
Declared. N/A 
2.7.2 
This subclause has been declared ‘void’. 
Declared. 
N/A 
3.2.3 
Delete the NOTE in Table 3A, and delete also in 
this table the conduit sizes in parentheses. 
Delete. N/A 
Issue Date: 
2014-08-11 
Page 9 of 20 
Report Reference #
BTL-CB-1-S1407C070
 
 
 
 
 
IEC60950_1F - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
 
 
 
 
 
IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
 
Clause 
Requirement + Test 
Result - Remark 
Verdict
3.2.5.1 
Replace  
“60245 IEC 53” by “H05 RR-F”;  
 
 
“60227 IEC 52” by “H03 VV-F or  
  H03 
VVH2-F”; 
 
 
 
“60227 IEC 53” by “H05 VV-F or  
  H05 
VVH2-F2”. 
In Table 3B, replace the first four lines by the 
following: 
Up to and including 6 |  
 
 
 0,75 
a) 
|  
Over 6 up to and including 10| (0,75) 
b)
    1,0     | 
Over 10 up to and including 16| (1,0) 
c)
    1,5     | 
In the conditions applicable to Table 3B delete the 
words “in some countries” in condition 
a)
In NOTE 1, applicable to Table 3B, delete the 
second sentence. 
Replaced. N/A 
3.2.5.1 
(A2:2013)
 
NOTE Z1 
The harmonised code designations 
corresponding to the IEC cord types are given in Annex ZD
 
 
N/A 
3.3.4 
In Table 3D, delete the fourth line: conductor sizes 
for 10 to 13 A, and replace with the following: 
Over 10 up to and including 16 | 1,5 to 2,5 | 1,5 to 
4  
Delete the fifth line: conductor sizes for 13 to 16 A
Delete. N/A 
4.3.13.6 
(A1:2010)
 
Replace the existing NOTE by the following: 
NOTE Z1 Attention is drawn to: 
1999/519/EC: Council Recommendation on the limitation 
of exposure of the general public to electromagnetic 
fields 0 Hz to 300 GHz, and 
2006/25/EC: Directive on the minimum health and safety 
requirements regarding the exposure of workers to risks 
arising from physical agents (artifical optical radiation). 
Replaced. N/A 
 
Standards taking into account mentioned 
Recommendation and Directive which demonstrate 
compliance with the applicable EU Directive are 
indicated in the OJEC.
 
 N/A 
Annex H 
Replace the last paragraph of this annex by: 
At any point 10 cm from the surface of the 
OPERATOR ACCESS AREA, the dose rate shall 
not exceed 1 μSv/h (0,1 mR/h) (see NOTE). 
Account is taken of the background level. 
Replace the notes as follows: 
NOTE These values appear in Directive 96/29/Euratom.
Delete NOTE 2. 
Replaced. N/A 
Page of 127
Display

Click on the first or last page to see other EMC - CB Certificate (serv.man6) service manuals if exist.