JBL EMC - CB Certificate (serv.man6) EMC - CB Certificate ▷ View online
Issue Date:
2014-08-11
Page 6 of 20
Report Reference #
BTL-CB-1-S1407C070
IEC60950_1F - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause
Requirement + Test
Result - Remark
Verdict
Zx.3 Warning
The warning shall be placed on the equipment, or
on the packaging, or in the instruction manual and
shall consist of the following:
the symbol of Figure 1 with a minimum height of
5 mm; and
the following wording, or similar:
The warning shall be placed on the equipment, or
on the packaging, or in the instruction manual and
shall consist of the following:
the symbol of Figure 1 with a minimum height of
5 mm; and
the following wording, or similar:
“To prevent possible hearing damage, do not listen
at high volume levels for long periods.”
at high volume levels for long periods.”
Figure 1 – Warning label (IEC 60417-6044)
Alternatively, the entire warning may be given
through the equipment display during use, when
the user is asked to acknowledge activation of the
higher level.
through the equipment display during use, when
the user is asked to acknowledge activation of the
higher level.
N/A
Zx.4 Requirements for listening devices (headphones and earphones)
N/A
Zx.4.1 Wired listening devices with analogue
input
With 94 dBA sound pressure output L
input
With 94 dBA sound pressure output L
Aeq,T
, the
input voltage of the fixed “programme simulation
noise” described in EN 50332-2 shall be ≥ 75 mV.
noise” described in EN 50332-2 shall be ≥ 75 mV.
This requirement is applicable in any mode where
the headphones can operate (active or
passive), including any available setting (for
example built-in volume level control).
the headphones can operate (active or
passive), including any available setting (for
example built-in volume level control).
NOTE The values of 94 dBA – 75 mV correspond with 85dBA –
27 mV and 100 dBA – 150 mV.
27 mV and 100 dBA – 150 mV.
N/A
Issue Date:
2014-08-11
Page 7 of 20
Report Reference #
BTL-CB-1-S1407C070
IEC60950_1F - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause
Requirement + Test
Result - Remark
Verdict
Zx.4.2 Wired listening devices with digital input
With any playing device playing the fixed
“programme simulation noise” described in EN
50332-1 (and respecting the digital interface
standards, where a digital interface standard exists
that specifies the equivalent acoustic level), the
acoustic output L
With any playing device playing the fixed
“programme simulation noise” described in EN
50332-1 (and respecting the digital interface
standards, where a digital interface standard exists
that specifies the equivalent acoustic level), the
acoustic output L
Aeq,T
of the listening device shall
be ≤ 100 dBA.
This requirement is applicable in any mode where
the headphones can operate, including any
available setting (for example built-in volume level
control, additional sound feature like equalization,
etc.).
the headphones can operate, including any
available setting (for example built-in volume level
control, additional sound feature like equalization,
etc.).
NOTE An example of a wired listening device with digital input
is a USB headphone.
is a USB headphone.
N/A
Zx.4.3 Wireless listening devices
In wireless mode:
with any playing and transmitting device playing
the fixed programme simulation noise described
in EN 50332-1; and
respecting the wireless transmission standards,
where an air interface standard exists that
specifies the equivalent acoustic level; and
with volume and sound settings in the listening
device (for example built-in volume level control,
additional sound feature like equalization, etc.)
set to the combination of positions that
maximize the measured acoustic output for the
abovementioned programme simulation noise,
the acoustic output L
In wireless mode:
with any playing and transmitting device playing
the fixed programme simulation noise described
in EN 50332-1; and
respecting the wireless transmission standards,
where an air interface standard exists that
specifies the equivalent acoustic level; and
with volume and sound settings in the listening
device (for example built-in volume level control,
additional sound feature like equalization, etc.)
set to the combination of positions that
maximize the measured acoustic output for the
abovementioned programme simulation noise,
the acoustic output L
Aeq,T
of the listening device
shall be ≤ 100 dBA.
NOTE An example of a wireless listening device is a Bluetooth
headphone.
headphone.
N/A
Zx.5 Measurement methods
Measurements shall be made in accordance with
EN 50332-1 or EN 50332-2 as applicable.
Unless stated otherwise, the time interval T shall
be 30 s.
Measurements shall be made in accordance with
EN 50332-1 or EN 50332-2 as applicable.
Unless stated otherwise, the time interval T shall
be 30 s.
NOTE Test method for wireless equipment provided without
listening device should be defined.
listening device should be defined.
N/A
Issue Date:
2014-08-11
Page 8 of 20
Report Reference #
BTL-CB-1-S1407C070
IEC60950_1F - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause
Requirement + Test
Result - Remark
Verdict
2.7.1
Replace the subclause as follows:
Basic requirements
To protect against excessive current, short-circuits
and earth faults in PRIMARY CIRCUITS, protective
devices shall be included either as integral parts of
the equipment or as parts of the building
installation, subject to the following, a), b) and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the requirements
of 5.3 shall be included as parts of the equipment;
b) for components in series with the mains input to
the equipment such as the supply cord, appliance
coupler, r.f.i. filter and switch, short-circuit and
earth fault protection may be provided by
protective devices in the building installation;
Basic requirements
To protect against excessive current, short-circuits
and earth faults in PRIMARY CIRCUITS, protective
devices shall be included either as integral parts of
the equipment or as parts of the building
installation, subject to the following, a), b) and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the requirements
of 5.3 shall be included as parts of the equipment;
b) for components in series with the mains input to
the equipment such as the supply cord, appliance
coupler, r.f.i. filter and switch, short-circuit and
earth fault protection may be provided by
protective devices in the building installation;
Replaced.
N/A
c) it is permitted for PLUGGABLE EQUIPMENT
TYPE B or PERMANENTLY CONNECTED
EQUIPMENT, to rely on dedicated overcurrent and
short-circuit protection in the building installation,
provided that the means of protection, e.g. fuses or
circuit breakers, is fully specified in the installation
instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for PLUGGABLE EQUIPMENT
TYPE A the building installation shall be regarded
as providing protection in accordance with the
rating of the wall socket outlet.
TYPE B or PERMANENTLY CONNECTED
EQUIPMENT, to rely on dedicated overcurrent and
short-circuit protection in the building installation,
provided that the means of protection, e.g. fuses or
circuit breakers, is fully specified in the installation
instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for PLUGGABLE EQUIPMENT
TYPE A the building installation shall be regarded
as providing protection in accordance with the
rating of the wall socket outlet.
Declared. N/A
2.7.2
This subclause has been declared ‘void’.
Declared.
N/A
3.2.3
Delete the NOTE in Table 3A, and delete also in
this table the conduit sizes in parentheses.
this table the conduit sizes in parentheses.
Delete. N/A
Issue Date:
2014-08-11
Page 9 of 20
Report Reference #
BTL-CB-1-S1407C070
IEC60950_1F - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause
Requirement + Test
Result - Remark
Verdict
3.2.5.1
Replace
“60245 IEC 53” by “H05 RR-F”;
“60227 IEC 52” by “H03 VV-F or
H03
VVH2-F”;
“60227 IEC 53” by “H05 VV-F or
H05
VVH2-F2”.
In Table 3B, replace the first four lines by the
following:
Up to and including 6 |
following:
Up to and including 6 |
0,75
a)
|
Over 6 up to and including 10| (0,75)
b)
1,0 |
Over 10 up to and including 16| (1,0)
c)
1,5 |
In the conditions applicable to Table 3B delete the
words “in some countries” in condition
words “in some countries” in condition
a)
.
In NOTE 1, applicable to Table 3B, delete the
second sentence.
second sentence.
Replaced. N/A
3.2.5.1
(A2:2013)
NOTE Z1
The harmonised code designations
corresponding to the IEC cord types are given in Annex ZD
N/A
3.3.4
In Table 3D, delete the fourth line: conductor sizes
for 10 to 13 A, and replace with the following:
Over 10 up to and including 16 | 1,5 to 2,5 | 1,5 to
4
for 10 to 13 A, and replace with the following:
Over 10 up to and including 16 | 1,5 to 2,5 | 1,5 to
4
|
Delete the fifth line: conductor sizes for 13 to 16 A
Delete. N/A
4.3.13.6
(A1:2010)
Replace the existing NOTE by the following:
NOTE Z1 Attention is drawn to:
1999/519/EC: Council Recommendation on the limitation
of exposure of the general public to electromagnetic
fields 0 Hz to 300 GHz, and
of exposure of the general public to electromagnetic
fields 0 Hz to 300 GHz, and
2006/25/EC: Directive on the minimum health and safety
requirements regarding the exposure of workers to risks
arising from physical agents (artifical optical radiation).
requirements regarding the exposure of workers to risks
arising from physical agents (artifical optical radiation).
Replaced. N/A
Standards taking into account mentioned
Recommendation and Directive which demonstrate
compliance with the applicable EU Directive are
indicated in the OJEC.
Recommendation and Directive which demonstrate
compliance with the applicable EU Directive are
indicated in the OJEC.
N/A
Annex H
Replace the last paragraph of this annex by:
At any point 10 cm from the surface of the
OPERATOR ACCESS AREA, the dose rate shall
not exceed 1 μSv/h (0,1 mR/h) (see NOTE).
Account is taken of the background level.
Replace the notes as follows:
At any point 10 cm from the surface of the
OPERATOR ACCESS AREA, the dose rate shall
not exceed 1 μSv/h (0,1 mR/h) (see NOTE).
Account is taken of the background level.
Replace the notes as follows:
NOTE These values appear in Directive 96/29/Euratom.
Delete NOTE 2.
Replaced. N/A
Click on the first or last page to see other EMC - CB Certificate (serv.man6) service manuals if exist.