JBL EMC - CB Certificate (serv.man6) EMC - CB Certificate ▷ View online
Issue Date:
2014-08-11
Page 21 of 43
Report Reference #
BTL-CB-1-S1407C070
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
CRT
markings ........................................................ :
4.3.13.3
Effect of ultraviolet (UV) radiation on materials
N/A
Part, property, retention after test, flammability
classification .......................................................... :
classification .......................................................... :
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation ....... : N/A
4.3.13.5
Lasers (including laser diodes) and LEDs
See below.
P
4.3.13.5.1 Lasers (including laser diodes)
N/A
Laser class ............................................................ :
4.3.13.5.2 Light emitting diodes (LEDs)
This product contains only
visible indicator LEDs.
visible indicator LEDs.
P
4.3.13.6 Other types ............................................................ : N/A
4.4
Protection against hazardous moving parts
N/A
4.4.1 General
N/A
4.4.2
Protection in operator access areas ...................... : N/A
Household and home/office document/media
shredders
shredders
N/A
4.4.3
Protection in restricted access locations ............... : N/A
4.4.4
Protection in service access areas
N/A
4.4.5
Protection against moving fan blades
N/A
4.4.5.1 General
N/A
Not considered to cause pain or injury. a)……… .. .: N/A
Is considered to cause pain, not injury. b) … . ……:
N/A
Considered to cause injury. c) … . ……:
N/A
4.4.5.2
Protection for users
N/A
Use of symbol or warning ………………… . ………:
N/A
4.4.5.3
Protection for service persons
N/A
Use of symbol or warning ………………… . ………:
N/A
4.5 Thermal
requirements
P
4.5.1 General
Considered.
P
4.5.2
Temperature tests
(see appended table 4.5)
P
Normal load condition per Annex L ....................... : (see Annex L)
4.5.3
Temperature limits for materials
(see appended table 4.5)
P
4.5.4
Touch temperature limits
(see appended table 4.5)
P
4.5.5 Resistance
to abnormal heat ................................. : N/A
Issue Date:
2014-08-11
Page 22 of 43
Report Reference #
BTL-CB-1-S1407C070
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
4.6
Openings in enclosures
P
4.6.1
Top and side openings
No openings.
P
Dimensions (mm) .................................................. :
4.6.2
Bottoms of fire enclosures
No openings.
P
Construction of the bottomm, dimensions (mm) ... :
4.6.3
Doors or covers in fire enclosures
N/A
4.6.4
Openings in transportable equipment
N/A
4.6.4.1
Constructional design measures
N/A
Dimensions (mm) .................................................. :
4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
N/A
4.6.5
Adhesives for constructional purposes
N/A
Conditioning temperature (
C), time (weeks) ......... :
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame
See below.
P
Method 1, selection and application of components
wiring and materials
wiring and materials
Use of materials with the
required flammability classes.
required flammability classes.
P
Method 2, application of all of simulated fault
condition tests
condition tests
Method 2 no used.
N/A
4.7.2
Conditions for a fire enclosure
See below.
P
4.7.2.1
Parts requiring a fire enclosure
See 4.7.2.2
N/A
4.7.2.2
Parts not requiring a fire enclosure
External adaptor complies
with LPS.
with LPS.
P
4.7.3 Materials
See
below.
P
4.7.3.1
General
See appended table 1.5.1 for
details.
details.
P
4.7.3.2
Materials for fire enclosures
N/A
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
No such components.
N/A
4.7.3.4
Materials for components and other parts inside
fire enclosures
fire enclosures
All electronic component are
mounted on V-1 or better.
mounted on V-1 or better.
N/A
4.7.3.5
Materials for air filter assemblies
No air filter provided.
N/A
4.7.3.6
Materials used in high-voltage components
No high voltage component.
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
P
Issue Date:
2014-08-11
Page 23 of 43
Report Reference #
BTL-CB-1-S1407C070
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
5.1
Touch current and protective conductor current
N/A
5.1.1
General
Class lll equipment.
N/A
5.1.2
Configuration of equipment under test (EUT)
N/A
5.1.2.1
Single connection to an a.c. mains supply
N/A
5.1.2.2
Redundant multiple connections to an a.c. mains
supply
supply
N/A
5.1.2.3
Simultaneous multiple connections to an a.c. mains
supply
supply
N/A
5.1.3 Test
circuit
N/A
5.1.4
Application of measuring instrument
N/A
5.1.5 Test
procedure
N/A
5.1.6 Test
measurements
N/A
Supply
voltage (V) ................................................. :
Measured touch current (mA) ................................ :
Max. allowed touch current (mA) ........................... :
Measured protective conductor current (mA) ........ :
Max. allowed protective conductor current (mA) .... :
5.1.7
Equipment with touch current exceeding 3,5 mA
N/A
5.1.7.1 General .................................................................. : N/A
5.1.7.2
Simultaneous multiple connections to the supply
N/A
5.1.8
Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks
cable distribution systems and from
telecommunication networks
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network or to a cable
distribution system
telecommunication network or to a cable
distribution system
N/A
Supply
voltage (V) ................................................. :
Measured touch current (mA) ................................ :
Max. allowed touch current (mA) ........................... :
5.1.8.2
Summation of touch currents from
telecommunication networks
telecommunication networks
N/A
a) EUT with earthed telecommunication ports ...... : N/A
b) EUT whose telecommunication ports have no
reference to protective earth
reference to protective earth
N/A
5.2 Electric
strength
N/A
5.2.1
General
Class lll equipment.
N/A
5.2.2
Test procedure
N/A
Issue Date:
2014-08-11
Page 24 of 43
Report Reference #
BTL-CB-1-S1407C070
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
5.3
Abnormal operating and fault conditions
P
5.3.1
Protection against overload and abnormal
operation
operation
(see appended table 5.3)
P
5.3.2 Motors
N/A
5.3.3 Transformers
No safety isolation
transformer.
transformer.
N/A
5.3.4 Functional insulation ............................................... : Method c). Test results see
appended table 5.3.
P
5.3.5
Electromechanical components
No electromechanical
component.
component.
N/A
5.3.6
Audio amplifiers in ITE ........................................... :
P
5.3.7
Simulation of faults
(see appended table 5.3)
P
5.3.8 Unattended
equipment
Neither thermostat or
temperature limiter nor thermal
cut-out provided.
temperature limiter nor thermal
cut-out provided.
N/A
5.3.9
Compliance criteria for abnormal operating and
fault conditions
fault conditions
See below.
P
5.3.9.1
During the tests
No fire propagated beyond the
equipment.
equipment.
P
5.3.9.2
After the tests
N/A
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of
other equipment connected to the network, from hazards in the equipment
other equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1 Requirements
N/A
Supply
voltage (V) ................................................. :
Current in the test circuit (mA) ............................. :
6.1.2.2 Exclusions .............................................................. :
N/A
6.2
Protection of equipment users from overvoltages on telecommunication
networks
networks
N/A
6.2.1 Separation
requirements
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1 Impulse
test
N/A
6.2.2.2 Steady-state
test
N/A
Click on the first or last page to see other EMC - CB Certificate (serv.man6) service manuals if exist.