2014-08-11 
Page 21 of 43 
Report Reference #
BTL-CB-1-S1407C070
 
 
 
 
 IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1F 
 
 
 
 
 CRT 
markings  ........................................................ :  
 
4.3.13.3 
Effect of ultraviolet (UV) radiation on materials 
 
N/A 
 
Part, property, retention after test, flammability 
classification  .......................................................... :
 N/A 
4.3.13.4 
Human exposure to ultraviolet (UV) radiation  ....... :   N/A 
4.3.13.5 
Lasers (including laser diodes) and LEDs 
See below. 
4.3.13.5.1  Lasers (including laser diodes) 
 
N/A 
 
Laser class  ............................................................ :  
 
4.3.13.5.2  Light emitting diodes (LEDs) 
This product contains only 
visible indicator LEDs. 
4.3.13.6 Other types  ............................................................ :   N/A 
 
4.4 
Protection against hazardous moving parts 
N/A 
4.4.1 General 
 
N/A 
4.4.2 
Protection in operator access areas  ...................... :   N/A 
 
Household and home/office document/media 
shredders 
 N/A 
4.4.3 
Protection in restricted access locations  ............... :   N/A 
4.4.4 
Protection in service access areas 
 
N/A 
4.4.5 
Protection against moving fan blades 
 
N/A 
4.4.5.1 General 
 
N/A 
 
Not considered to cause pain or injury. a)……… .. .:  N/A 
 
Is considered to cause pain, not injury. b) … . ……:  
N/A 
 
Considered to cause injury.                   c) … . ……:   
N/A 
4.4.5.2 
Protection for users 
 
N/A 
 
Use of symbol or warning ………………… . ………:  
N/A 
4.4.5.3 
Protection for service persons 
 
N/A 
 
Use of symbol or warning ………………… . ………:  
N/A 
 
4.5 Thermal 
requirements 
4.5.1 General 
Considered. 
4.5.2 
Temperature tests 
(see appended table 4.5) 
 
Normal load condition per Annex L  ....................... : (see Annex L) 
 
4.5.3 
Temperature limits for materials 
(see appended table 4.5) 
4.5.4 
Touch temperature limits 
(see appended table 4.5) 
4.5.5 Resistance 
to abnormal heat  ................................. :   N/A 
Issue Date: 
2014-08-11 
Page 22 of 43 
Report Reference #
BTL-CB-1-S1407C070
 
 
 
 
 IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1F 
 
 
 
 
 
4.6 
Openings in enclosures
 
4.6.1 
Top and side openings 
No openings. 
 Dimensions (mm)  .................................................. :  
 
4.6.2 
Bottoms of fire enclosures 
No openings. 
 
Construction of the bottomm, dimensions (mm)  ... :  
 
4.6.3 
Doors or covers in fire enclosures 
 
N/A 
4.6.4 
Openings in transportable equipment 
 
N/A 
4.6.4.1 
Constructional design measures 
 
N/A 
 Dimensions (mm)  .................................................. :  
 
4.6.4.2 
Evaluation measures for larger openings 
 
N/A 
4.6.4.3 
Use of metallized parts 
 
N/A 
4.6.5 
Adhesives for constructional purposes 
 
N/A 
 
Conditioning temperature (
C), time (weeks) ......... :  
 
 
4.7 
Resistance to fire
 
4.7.1 
Reducing the risk of ignition and spread of flame 
See below. 
 
Method 1, selection and application of components 
wiring and materials 
Use of materials with the 
required flammability classes. 
 
Method 2, application of all of simulated fault 
condition tests 
Method 2 no used. 
N/A 
4.7.2 
Conditions for a fire enclosure 
See below. 
4.7.2.1 
Parts requiring a fire enclosure 
See 4.7.2.2 
N/A 
4.7.2.2 
Parts not requiring a fire enclosure 
External adaptor complies 
with LPS. 
4.7.3 Materials 
See 
below. 
4.7.3.1 
General 
See appended table 1.5.1 for 
details. 
4.7.3.2 
Materials for fire enclosures 
 
N/A 
4.7.3.3 
Materials for components and other parts outside 
fire enclosures 
No such components. 
N/A 
4.7.3.4 
Materials for components and other parts inside 
fire enclosures 
All electronic component are 
mounted on V-1 or better. 
N/A 
4.7.3.5 
Materials for air filter assemblies 
No air filter provided. 
N/A 
4.7.3.6 
Materials used in high-voltage components 
No high voltage component. 
N/A 
 
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
 
Issue Date: 
2014-08-11 
Page 23 of 43 
Report Reference #
BTL-CB-1-S1407C070
 
 
 
 
 IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1F 
 
 
 
 
5.1 
Touch current and protective conductor current 
N/A 
5.1.1 
General 
Class lll equipment. 
N/A 
5.1.2 
Configuration of equipment under test (EUT) 
 
N/A 
5.1.2.1 
Single connection to an a.c. mains supply 
 
N/A 
5.1.2.2 
Redundant multiple connections to an a.c. mains 
supply 
 N/A 
5.1.2.3 
Simultaneous multiple connections to an a.c. mains 
supply 
 N/A 
5.1.3 Test 
circuit 
 
N/A 
5.1.4 
Application of measuring instrument 
 
N/A 
5.1.5 Test 
procedure 
 
N/A 
5.1.6 Test 
measurements 
 
N/A 
 Supply 
voltage (V)  ................................................. :  
 
 
Measured touch current (mA)  ................................ :  
 
 
Max. allowed touch current (mA)  ........................... :  
 
 
Measured protective conductor current (mA)  ........ :  
 
 
Max. allowed protective conductor current (mA) .... :  
 
5.1.7 
Equipment with touch current exceeding 3,5 mA 
 
N/A 
5.1.7.1 General  .................................................................. :   N/A 
5.1.7.2 
Simultaneous multiple connections to the supply 
 
N/A 
5.1.8 
Touch currents to telecommunication networks and 
cable distribution systems and from 
telecommunication networks 
 N/A 
5.1.8.1 
Limitation of the touch current to a 
telecommunication network or to a cable 
distribution system 
 N/A 
 Supply 
voltage (V)  ................................................. :  
 
 
Measured touch current (mA)  ................................ :  
 
 
Max. allowed touch current (mA)  ........................... :  
 
5.1.8.2 
Summation of touch currents from 
telecommunication networks 
 N/A 
 
a) EUT with earthed telecommunication ports  ...... :   N/A 
 
b) EUT whose telecommunication ports have no 
reference to protective earth 
 N/A 
 
5.2 Electric 
strength
 
N/A 
5.2.1 
General 
Class lll equipment. 
N/A 
5.2.2 
Test procedure  
 
N/A 
Issue Date: 
2014-08-11 
Page 24 of 43 
Report Reference #
BTL-CB-1-S1407C070
 
 
 
 
 IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1F 
 
 
 
 
 
5.3 
Abnormal operating and fault conditions 
5.3.1 
Protection against overload and abnormal 
operation 
(see appended table 5.3)  
    P 
5.3.2 Motors 
 
N/A 
5.3.3 Transformers 
No safety isolation 
transformer. 
N/A 
5.3.4 Functional insulation ............................................... : Method c). Test results see 
appended table 5.3. 
5.3.5 
Electromechanical components 
No electromechanical 
component. 
N/A 
5.3.6 
Audio amplifiers in ITE  ........................................... :  
5.3.7 
Simulation of faults 
(see appended table 5.3) 
5.3.8 Unattended 
equipment 
Neither thermostat or 
temperature limiter nor thermal 
cut-out provided. 
N/A 
5.3.9 
Compliance criteria for abnormal operating and 
fault conditions 
See below. 
5.3.9.1 
During the tests 
No fire propagated beyond the 
equipment. 
5.3.9.2 
After the tests 
 
N/A 
 
CONNECTION TO TELECOMMUNICATION NETWORKS
 
N/A 
6.1 
Protection of telecommunication network service persons, and users of 
other equipment connected to the network, from hazards in the equipment 
N/A 
6.1.1 
Protection from hazardous voltages 
N/A 
6.1.2 
Separation of the telecommunication network from earth 
N/A 
6.1.2.1 Requirements 
 
N/A 
 Supply 
voltage (V)  ................................................. :  
 
 
Current  in the test circuit  (mA)  ............................. :  
 
6.1.2.2 Exclusions .............................................................. :  
N/A 
 
6.2 
Protection of equipment users from overvoltages on telecommunication 
networks 
N/A 
6.2.1 Separation 
requirements 
 
N/A 
6.2.2 
Electric strength test procedure 
 
N/A 
6.2.2.1 Impulse 
test 
 
N/A 
6.2.2.2 Steady-state 
test 
 
N/A 
Page of 127