Issue Date:
2014-08-11
Page 17 of 43
Report Reference #
BTL-CB-1-S1407C070
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
2.10.11
Tests for semiconductor devices and cemented
joints
joints
N/A
2.10.12
Enclosed and sealed parts
N/A
3
WIRING, CONNECTIONS AND SUPPLY
P
3.1 General
P
3.1.1
Current rating and overcurrent protection
P
3.1.2
Protection against mechanical damage
Wires do not touch sharp
edges which could damage
the insulation and cause
hazard.
edges which could damage
the insulation and cause
hazard.
P
3.1.3
Securing of internal wiring
The wires are secured by
soldering, solder pins and
quick connect terminals so
that a loosening of the
terminal connection is
unlikely.
soldering, solder pins and
quick connect terminals so
that a loosening of the
terminal connection is
unlikely.
P
3.1.4
Insulation of conductors
N/A
3.1.5
Beads and ceramic insulators
N/A
3.1.6
Screws for electrical contact pressure
N/A
3.1.7
Insulating materials in electrical connections
N/A
3.1.8
Self-tapping and spaced thread screws
N/A
3.1.9
Termination of conductors
All terminations are fixed
reliable.
reliable.
P
10 N pull test
Complied.
P
3.1.10
Sleeving on wiring
N/A
3.2
Connection to a mains supply
N/A
3.2.1
Means of connection
N/A
3.2.1.1
Connection to an a.c. mains supply
N/A
3.2.1.2
Connection to a d.c. mains supply
N/A
3.2.2
Multiple supply connections
N/A
3.2.3
Permanently connected equipment
N/A
Number of conductors, diameter of cable and
conduits (mm) ....................................................... :
conduits (mm) ....................................................... :
3.2.4 Appliance
inlets
N/A
Issue Date:
2014-08-11
Page 18 of 43
Report Reference #
BTL-CB-1-S1407C070
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
3.2.5
Power supply cords
N/A
3.2.5.1
AC power supply cords
N/A
Type
......................................................................
:
Rated current (A), cross-sectional area (mm
2
),
AWG ..................................................................... :
3.2.5.2
DC power supply cords
N/A
3.2.6
Cord anchorages and strain relief
N/A
Mass of equipment (kg), pull (N) ......................... :
Longitudinal
displacement (mm) .......................... :
3.2.7
Protection against mechanical damage
N/A
3.2.8 Cord
guards
N/A
Diameter or minor dimension D (mm); test mass
(g) ......................................................................... :
(g) ......................................................................... :
Radius of curvature of cord (mm) .......................... :
3.2.9
Supply wiring space
N/A
3.3
Wiring terminals for connection of external conductors
N/A
3.3.1 Wiring
terminals
N/A
3.3.2
Connection of non-detachable power supply cords
N/A
3.3.3 Screw
terminals
N/A
3.3.4
Conductor sizes to be connected
N/A
Rated current (A), cord/cable type, cross-sectional
area (mm
area (mm
2
) ............................................................. :
3.3.5
Wiring terminal sizes
N/A
Rated current (A), type, nominal thread diameter
(mm) ..................................................................... :
(mm) ..................................................................... :
3.3.6
Wiring terminal design
N/A
3.3.7
Grouping of wiring terminals
N/A
3.3.8 Stranded
wire
N/A
3.4
Disconnection from the mains supply
N/A
3.4.1 General
requirement
N/A
3.4.2 Disconnect
devices
N/A
3.4.3
Permanently connected equipment
N/A
3.4.4
Parts which remain energized
N/A
3.4.5
Switches in flexible cords
N/A
3.4.6
Number of poles - single-phase and d.c. equipment
N/A
Issue Date:
2014-08-11
Page 19 of 43
Report Reference #
BTL-CB-1-S1407C070
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
3.4.7
Number of poles - three-phase equipment
N/A
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10 Interconnected
equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
P
3.5.1
General requirements
See below.
P
3.5.2
Types of interconnection circuits .......................... : Interconnection circuits of
SELV through secondary
output connector.
output connector.
P
3.5.3
ELV circuits as interconnection circuits
No ELV interconnection.
N/A
3.5.4
Data ports for additional equipment
See clause 2.5 for details.
P
4 PHYSICAL
REQUIREMENTS
P
4.1 Stability
N/A
Angle of 10
N/A
Test
force (N) ......................................................... : N/A
4.2 Mechanical
strength
N/A
4.2.1 General
N/A
Rack-mounted equipment.
N/A
4.2.2
Steady force test, 10 N
N/A
4.2.3
Steady force test, 30 N
N/A
4.2.4
Steady force test, 250 N
N/A
4.2.5 Impact
test
N/A
Fall
test
N/A
Swing
test
N/A
4.2.6
Drop test; height (mm) ...........................................:
N/A
4.2.7
Stress relief test
N/A
4.2.8
Cathode ray tubes
N/A
Picture tube separately certified ............................:
N/A
4.2.9
High pressure lamps
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) .......:
N/A
4.3
Design and construction
P
Issue Date:
2014-08-11
Page 20 of 43
Report Reference #
BTL-CB-1-S1407C070
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
4.3.1
Edges and corners
Edges and corners of the
enclosure are rounded.
enclosure are rounded.
P
4.3.2
Handles and manual controls; force (N) ............. :
N/A
4.3.3
Adjustable controls
N/A
4.3.4
Securing of parts
No connections likely to be
exposed to mechanical stress
are inside the unit.
exposed to mechanical stress
are inside the unit.
P
4.3.5
Connection by plugs and sockets
No mismatch of connectors,
plugs or socket possible.
plugs or socket possible.
P
4.3.6
Direct plug-in equipment
N/A
Torque
..................................................................:
Compliance with the relevant mains plug standard
...............................................................................:
...............................................................................:
N/A
4.3.7
Heating elements in earthed equipment
N/A
4.3.8
Batteries
The test is performed the
protective component of the
RTC battery.
The reverse current protection
is accomplished by series
diode.
protective component of the
RTC battery.
The reverse current protection
is accomplished by series
diode.
P
- Overcharging of a rechargeable battery
N/A
- Unintentional charging of a non-rechargeable
battery
battery
The reverse current protection
component of RTC Battery
was shorted. (see appended
table 4.3.8)
component of RTC Battery
was shorted. (see appended
table 4.3.8)
P
- Reverse charging of a rechargeable battery
Battery polarity can’t be
reversed according design.
reversed according design.
N/A
- Excessive discharging rate for any battery
N/A
4.3.9
Oil and grease
N/A
4.3.10
Dust, powders, liquids and gases
N/A
4.3.11
Containers for liquids or gases
N/A
4.3.12 Flammable liquids .................................................. : N/A
Quantity
of
liquid (l) ................................................ : N/A
Flash point (
C) ...................................................... : N/A
4.3.13 Radiation
LED
indicators.
P
4.3.13.1 General
N/A
4.3.13.2
Ionizing radiation
N/A
Measured
radiation (pA/kg) ................................... :
Measured
high-voltage (kV) .................................. :
Measured
focus
voltage (kV) ................................. :