JBL EMC - CB Certificate (serv.man6) EMC - CB Certificate ▷ View online
Issue Date:
2014-08-11
Page 5 of 43
Report Reference #
BTL-CB-1-S1407C070
TRF No. IEC60950_1F
Copy of marking plate
The artwork below may be only a draft. The use of certification marks on a product must be
authorized by the respective NCBs that own these marks.
authorized by the respective NCBs that own these marks.
(Additional requirements for markings. See 1.7 NOTE)
Remark:
1). Trademark “JBL” applied on enclosure of product.
Issue Date:
2014-08-11
Page 6 of 43
Report Reference #
BTL-CB-1-S1407C070
TRF No. IEC60950_1F
Test item particulars
.................................................. :
Equipment mobility ................................................. :
[X] movable [] hand-held [] transportable
[] stationary [] for building-in [] direct plug-in
Connection to the mains ........................................ :
[] pluggable equipment [] type A [] type B
[] permanent connection
[] detachable power supply cord
[] non-detachable power supply cord
[X] not directly connected to the mains
[] detachable power supply cord
[] non-detachable power supply cord
[X] not directly connected to the mains
Operating condition ................................................ :
[X] continuous
[] rated operating / resting time:
Access location
...................................................... : [X] operator accessible
[] restricted access location
Over voltage category (OVC)
................................ : [] OVC I [] OVC II [] OVC III [] OVC IV
[X] other: Not directly connected to the mains
Mains supply tolerance (%) or absolute mains
supply values ......................................................... :
supply values ......................................................... :
N/A
Tested for IT power systems
................................ : [] Yes [X] No
IT testing, phase-phase voltage (V)
..................... : N/A
Class of equipment
................................................ : [] Class I [] Class II [X] Class III
[] Not classified
Considered current rating of protective device as
part of the building installation (A)
part of the building installation (A)
...................... :
Not directly connected to the mains
Pollution degree (PD)
............................................ : [] PD 1 [X] PD 2 [] PD 3
IP protection class
................................................. : IP20
Altitude during operation (m) ............................... :
Up to 2000 m
Altitude of test laboratory (m) ............................... :
Not over 2000 m
Mass of equipment (kg)
......................................... : Approx. 0.9 kg
Possible test case verdicts:
- test case does not apply to the test object ........... :
N/A
- test object does meet the requirement .................. :
P (Pass)
- test object does not meet the requirement ........... :
F (Fail)
Testing .......................................................................... :
Date of receipt of test item ......................................... :
2014-07-15
Date(s) of performance of tests ................................ :
2014-07-15 to 2014-07-18
General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
Throughout this report a
"(See appended table)" refers to a table appended to the report.
Throughout this report a
comma /
point is used as the decimal separator.
Issue Date:
2014-08-11
Page 7 of 43
Report Reference #
BTL-CB-1-S1407C070
TRF No. IEC60950_1F
Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ................................................................ :
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ................................................................ :
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... :
Shenzhen 3Nod Digital Technology Co., Ltd.
Building D Park 8# Langhui Road Tangxiayong
Building D Park 8# Langhui Road Tangxiayong
Village Industrial Zone Songgang Town Baoan
District Shenzhen City China
General product information:
Report Summary
-
All applicable tests according to the referenced standard(s) have been carried out.
Product Description
-
The equipment model JBL HORIZON is a Bluetooth Speaker for use incorporation in information
technology equipment.
technology equipment.
-
The equipment is supplied from an approved external switching power adaptor which complies with
LPS.
LPS.
-
The enclosures secured together by screws and mechanical fixing.
Model Differences
- N/A.
Technical Considerations
1. The product was submitted and tested for use at the maximum ambient temperature (Tma) permitted by
the manufacturer’s specification of: 40 ºC
2. The external switching power adaptor used with the product is a certified product which was CB
scheme investigated according to the standard of IEC 60950-1:2005 2Ed +Am1:2009+Am2:2013. The
suitability of use has been evaluated in this report. See appended table 1.5.1 for the source details.
suitability of use has been evaluated in this report. See appended table 1.5.1 for the source details.
3. The
equipment
operated with altitude up to 2000m above sea level. For external power adaptor, the
operation altitude, if required by intended district or countries, shall be evaluated during its national
approval.
approval.
Abbreviations used in the report:
- normal conditions
- normal conditions
N.C.
-
single
fault
conditions
S.F.C
- functional insulation
OP
-
basic
insulation
BI
- double insulation
DI
-
supplementary
insulation
SI
- between parts of opposite
polarity
polarity
BOP
-
reinforced
insulation
RI
Indicate used abbreviations (if any)
Issue Date:
2014-08-11
Page 8 of 43
Report Reference #
BTL-CB-1-S1407C070
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
1
GENERAL
P
1.5 Components
P
1.5.1 General
See
below.
P
Comply with IEC 60950-1 or relevant component
standard
standard
(see appended table 1.5.1)
P
1.5.2
Evaluation and testing of components
Components certified to IEC
standards and/or their
harmonized standards, are
used within their ratings and
are checked for correct
application.
standards and/or their
harmonized standards, are
used within their ratings and
are checked for correct
application.
P
1.5.3 Thermal
controls
N/A
1.5.4 Transformers
N/A
1.5.5 Interconnecting
cables
Interconnecting cables comply
with the relevant requirements
of this standard.
with the relevant requirements
of this standard.
P
1.5.6
Capacitors bridging insulation
N/A
1.5.7
Resistors bridging insulation
N/A
1.5.7.1
Resistors bridging functional, basic or
supplementary insulation
supplementary insulation
N/A
1.5.7.2
Resistors bridging double or reinforced insulation
between a.c. mains and other circuits
between a.c. mains and other circuits
N/A
1.5.7.3
Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable
between a.c. mains and antenna or coaxial cable
N/A
1.5.8
Components in equipment for IT power systems
N/A
1.5.9 Surge
suppressors
N/A
1.5.9.1 General
N/A
1.5.9.2
Protection of VDRs
N/A
1.5.9.3
Bridging of functional insulation by a VDR
N/A
1.5.9.4
Bridging of basic insulation by a VDR
N/A
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR
insulation by a VDR
N/A
1.6 Power
interface
P
1.6.1
AC power distribution systems
N/A
1.6.2 Input
current
(see appended table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
N/A
1.6.4
Neutral conductor
N/A
Click on the first or last page to see other EMC - CB Certificate (serv.man6) service manuals if exist.