JBL DUET 200 (serv.man3) EMC - CB Certificate ▷ View online
- Page 9 of 62 -
Report
No. 111798
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
Symbol for Class II equipment only .......................: Class III equipment.
N
Other markings and symbols ................................: The additional marking does not
give rise to misunderstandings.
P
1.7.2
Safety instructions and marking
Provided with marking regarding
use of specified power supply,
refer to marking label.
use of specified power supply,
refer to marking label.
P
1.7.2.1 General
Considered.
—
1.7.2.2
Disconnect devices
Class III equipment.
N
1.7.2.3 Overcurrent
protective device
Class III equipment.
N
1.7.2.4
IT power distribution systems
N
1.7.2.5
Operator access with a tool
Class III equipment.
N
1.7.2.6
Ozone
The equipment does not
produce Ozone.
produce Ozone.
N
1.7.3
Short duty cycles
The equipment is intended for
continuous operation.
continuous operation.
N
1.7.4
Supply voltage adjustment ...................................: No
voltage
selector. N
Methods and means of adjustment; reference to
installation instructions .........................................:
installation instructions .........................................:
N
1.7.5
Power outlets on the equipment ...........................:
No standard power outlet.
N
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) ..........................:
characteristics, cross-reference) ..........................:
No fuses.
N
1.7.7
Wiring terminals
Class III equipment
N
1.7.7.1 Protective
earthing and bonding terminals ...........:
—
1.7.7.2
Terminals for a.c. mains supply conductors
—
1.7.7.3
Terminals for d.c. mains supply conductors
—
1.7.8
Controls and indicators
Refer below.
—
1.7.8.1 Identification,
location
and marking ......................: No
controls. N
1.7.8.2 Colours
................................................................: For
functional indication a LED
lights when the equipment is
operating.
operating.
N
- Page 10 of 62 -
Report
No. 111798
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
1.7.8.3
Symbols according to IEC 60417.........................:
The ON/OFF (push-push)
switch is marked with the
switch is marked with the
symbol "
" (IEC 60417-1 No.
5010).
P
1.7.8.4 Markings
using figures .......................................:
N
1.7.9
Isolation of multiple power sources .....................:
Class III equipment.
N
1.7.10
Thermostats and other regulating devices ..........:
No thermostats or other
regulating devices.
regulating devices.
N
1.7.11
Durability
The marking withstands
required tests.
required tests.
P
1.7.12
Removable parts
No removable parts.
N
1.7.13 Replaceable
batteries ..........................................:
No battery in the equipment.
N
Language(s)
........................................................:
⎯
1.7.14
Equipment for restricted access locations ...........:
Equipment not intended for
intallation in RAL.
intallation in RAL.
N
2
PROTECTION FROM HAZARDS
—
2.1
Protection from electric shock and energy hazards
—
2.1.1
Protection in operator access areas
Refer below:
—
2.1.1.1
Access to energized parts
Class III equipment.
N
Test by inspection .................................................:
—
Test with test finger (Figure 2A) ............................:
—
Test with test pin (Figure 2B) ................................:
—
Test with test probe (Figure 2C) ...........................:
—
2.1.1.2
Battery compartments
No TNV circuits in the
equipment.
equipment.
N
2.1.1.3
Access to ELV wiring
No internal wiring at ELV
accessible to the operator.
accessible to the operator.
N
Working voltage (Vpeak or Vrms); minimum distance
through insulation (mm)
through insulation (mm)
⎯
2.1.1.4
Access to hazardous voltage circuit wiring
Class III equipment.
N
2.1.1.5 Energy
hazards .....................................................:
Class III equipment, supplies
from a LPS.
from a LPS.
N
- Page 11 of 62 -
Report
No. 111798
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
2.1.1.6
Manual controls
No shafts of knobs etc. at ELV
or hazardous voltage.
or hazardous voltage.
N
2.1.1.7
Discharge of capacitors in equipment
Class III equipment.
N
Measured voltage (V); time-constant (s)................:
⎯
2.1.1.8
Energy hazards – d.c. mains supply
Supplied from SELV.
N
a) Capacitor connected to the d.c. mains supply ..:
N
N
2.1.1.9 Audio
amplifiers .....................................................:
See 2.1.1.1.
N
2.1.2
Protection in service access areas
Class III equipment.
N
2.1.3
Protection in restricted access locations
Equipment not intended for
installation in RAL.
installation in RAL.
N
Measuring instrument
Inv. no.
Date
2.2 SELV
circuits
⎯
2.2.1
General requirements
SELV limits are not exceeded
under normal condition and
after a single fault. Equipment
is powered from a SELV
source.
under normal condition and
after a single fault. Equipment
is powered from a SELV
source.
P
2.2.2
Voltages under normal conditions (V) ................... :
Powered by SELV source.
P
2.2.3
Voltages under fault conditions (V) ....................... :
Powered by SELV source.
P
2.2.4
Connection of SELV circuits to other circuits ...... :
SELV circuits are not
connected to other circuits than
protective earth.
connected to other circuits than
protective earth.
P
Measuring instrument
Inv. no.
Date
2.3 TNV
circuits
⎯
2.3.1 Limits
⎯
- Page 12 of 62 -
Report
No. 111798
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
Type of TNV circuits............................................... :
No TNV circuit.
⎯
2.3.2
Separation from other circuits and from accessible
parts
parts
N
2.3.2.1 General
requirements
N
2.3.2.2
Protection by basic insulation
⎯
2.3.2.3
Protection by earthing
⎯
2.3.2.4
Protection by other constructions ......................... :
⎯
2.3.3
Separation from hazardous voltages
N
Insulation
employed ............................................... :
⎯
2.3.4
Connection of TNV circuits to other circuits
N
Insulation
employed ............................................... :
⎯
2.3.5
Test for operating voltages generated externally
N
Measuring instrument
Inv. no.
Date
2.4
Limited current circuits
N
2.4.1
General requirements
No limited current circuits.
⎯
2.4.2 Limit
values
⎯
Frequency
(Hz) ...................................................... :
⎯
Measured
current (mA) .......................................... :
⎯
Measured
voltage (V)............................................. :
⎯
Measured circuit capacitance (nF or µF) ............... :
⎯
2.4.3
Connection of limited current circuits to other circuits
⎯
Measuring instrument
Inv. no.
Date
2.5
Limited power sources
⎯
Click on the first or last page to see other DUET 200 (serv.man3) service manuals if exist.