DOWNLOAD JBL DUET 200 (serv.man3) Service Manual ↓ Size: 424.93 KB | Pages: 62 in PDF or view online for FREE

Model
DUET 200 (serv.man3)
Pages
62
Size
424.93 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
duet-200-sm3.pdf
Date

JBL DUET 200 (serv.man3) EMC - CB Certificate ▷ View online

 
 
- Page 29 of 62 - 
 
 
 Report 
No. 111798 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
5.1.2.2 
Redundant multiple connections to an a.c. mains 
supply 
 N 
5.1.2.3 
Simultaneous multiple connections to an a.c. mains 
supply 
 N 
5.1.3 Test 
circuit 
 
5.1.4 
Application of measuring instrument 
 
5.1.5 Test 
procedure 
 
5.1.6 Test 
measurements 
 
 Supply 
voltage (V)  ................................................:  
⎯ 
 
Measured touch current (mA)  ..............................: 
 
⎯ 
 
Max. allowed touch current (mA)  .........................: 
 
⎯ 
 
Measured protective conductor current (mA) .......: 
 
⎯ 
 
Max. allowed protective conductor current (mA)...: 
 
⎯ 
5.1.7 
Equipment with touch current exceeding 3,5 mA 
 
5.1.7.1 General .................................................................: 
 
5.1.7.2 
Simultaneous multiple connections to the supply 
 
5.1.8 
Touch currents to telecommunication networks and 
cable distribution systems and from 
telecommunication networks 
Not connected to a 
telecommunication network nor
a cable distribution system. 
5.1.8.1 
Limitation of the touch current to a telecommunication 
network or to a cable distribution system 
 N 
 Supply 
voltage (V)  ................................................:  
⎯ 
 
Measured touch current (mA)  ..............................: 
 
⎯ 
 
Max. allowed touch current (mA)  .........................: 
 
⎯ 
5.1.8.2 
Summation of touch currents from telecommunication 
networks 
 N 
 
a) EUT with earthed telecommunication ports  .....: 
 
 
b) EUT whose telecommunication ports have no 
reference to protective earth 
 N 
 
 
 
- Page 30 of 62 - 
 
 
 Report 
No. 111798 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
5.2 Electric 
strength 
⎯ 
5.2.1 
General 
Functional insulation, no test 
required. 
5.2.2 
Test procedure  
 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
5.3 
Abnormal operating and fault conditions 
⎯ 
5.3.1 
Protection against overload and abnormal operation 
(see appended table 5.3)  
5.3.2 
Motors 
There is no motor in the 
equipment. 
5.3.3 
Transformers 
There are no safety 
transformers in the equipment.
5.3.4 Functional 
insulation .............................................: Complies with c). 
5.3.5 
Electromechanical components 
No electromechanical 
components in secondary 
circuits. 
5.3.6 
Audio amplifiers in ITE .........................................: 
See the enclosed fault 
condition tests. 
5.3.7 
Simulation of faults 
See the enclosed fault 
condition tests. 
5.3.8 Unattended 
equipment 
No 
thermostats, temperauter 
limiters or thermal cut-outs. 
5.3.9 
Compliance criteria for abnormal operating and fault 
conditions 
See below. 
5.3.9.1 
During the tests 
No fire or molten metal 
occurred and no deformation of
enclosure during the tests. 
 
 
- Page 31 of 62 - 
 
 
 Report 
No. 111798 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
5.3.9.2 
After the tests 
No hazard. Class III equipment
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
CONNECTION TO TELECOMMUNICATION NETWORKS 
⎯ 
6.1 
Protection of telecommunication network service persons, and users of other 
equipment connected to the network, from hazards in the equipment 
⎯ 
6.1.1 
Protection from hazardous voltages 
⎯ 
6.1.2 
Separation of the telecommunication network from earth 
⎯ 
6.1.2.1 
Requirements 
No TNV circuit. 
 Supply 
voltage (V)  ................................................:  
⎯ 
 
Current  in the test circuit  (mA)  ...........................: 
 
⎯ 
6.1.2.2 Exclusions ............................................................: 
 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
6.2 
Protection of equipment users from overvoltages on telecommunication networks 
⎯ 
6.2.1 Separation 
requirements 
 
6.2.2 
Electric strength test procedure 
 
6.2.2.1 Impulse 
test 
 
6.2.2.2 Steady-state 
test 
 
6.2.2.3 Compliance 
criteria 
 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
 
 
- Page 32 of 62 - 
 
 
 Report 
No. 111798 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
6.3 
Protection of the telecommunication wiring system from overheating 
⎯ 
 
Max. output current (A) .........................................: 
 
⎯ 
 Current 
limiting method  ........................................: 
 
⎯ 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
CONNECTION TO CABLE DISTRIBUTION SYSTEMS 
⎯ 
7.1 
General 
Not connected to Cable 
Distribution System. 
7.2 
Protection of cable distribution system service 
persons, and users of other equipment connected to 
the system, from hazardous voltages in the equipment
 N 
7.3 
Protection of equipment users from overvoltages on 
the cable distribution system 
 N 
7.4 
Insulation between primary circuits and cable 
distribution systems 
 N 
7.4.1 General 
 
7.4.2 
Voltage surge test 
 
7.4.3 Impulse 
test 
 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE 
⎯ 
A.1 
Flammability test for fire enclosures of movable 
equipment having a total mass exceeding 18 kg, and 
of stationary equipment (see 4.7.3.2) 
Not used. 
A.1.1 Samples ................................................................:  
⎯ 
 Wall 
thickness (mm)..............................................: 
 
⎯ 
A.1.2 
Conditioning of samples; temperature (
°C) ..........: 
 N 
Page of 62
Display