JBL DUET 200 (serv.man3) EMC - CB Certificate ▷ View online
- Page 21 of 62 -
Report
No. 111798
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
3.2
Connection to a mains supply
⎯
3.2.1
Means of connection
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
⎯
3.2.1.1
Connection to an a.c. mains supply
⎯
3.2.1.2
Connection to a d.c. mains supply
⎯
3.2.2
Multiple supply connections
⎯
3.2.3
Permanently connected equipment
⎯
Number of conductors, diameter of cable and
conduits (mm) .......................................................:
conduits (mm) .......................................................:
⎯
3.2.4 Appliance
inlets
⎯
3.2.5
Power supply cords
⎯
3.2.5.1
AC power supply cords
⎯
Type
......................................................................:
⎯
Rated current (A), cross-sectional area (mm
2
), AWG
...............................................................................:
⎯
3.2.5.2
DC power supply cords
⎯
3.2.6
Cord anchorages and strain relief
⎯
Mass of equipment (kg), pull (N) ..........................:
⎯
Longitudinal
displacement (mm) ...........................:
⎯
3.2.7
Protection against mechanical damage
⎯
3.2.8 Cord
guards
⎯
Diameter or minor dimension D (mm); test mass (g)
⎯
Radius of curvature of cord (mm) ..........................:
⎯
3.2.9
Supply wiring space
⎯
Measuring instrument
Inv. no.
Date
3.3
Wiring terminals for connection of external conductors
⎯
- Page 22 of 62 -
Report
No. 111798
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
3.3.1
Wiring terminals
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N
3.3.2
Connection of non-detachable power supply cords
N
3.3.3 Screw
terminals
N
3.3.4
Conductor sizes to be connected
N
Rated current (A), cord/cable type, cross-sectional
area (mm
area (mm
2
) .............................................................:
⎯
3.3.5
Wiring terminal sizes
N
Rated current (A), type, nominal thread diameter
(mm) ......................................................................:
(mm) ......................................................................:
⎯
3.3.6
Wiring terminal design
N
3.3.7
Grouping of wiring terminals
N
3.3.8 Stranded
wire
N
Measuring instrument
Inv. no.
Date
3.4
Disconnection from the mains supply
⎯
3.4.1
General requirement
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N
3.4.2 Disconnect
devices
⎯
3.4.3
Permanently connected equipment
⎯
3.4.4
Parts which remain energized
⎯
3.4.5
Switches in flexible cords
⎯
3.4.6
Number of poles - single-phase and d.c. equipment
⎯
3.4.7
Number of poles - three-phase equipment
⎯
3.4.8 Switches
as
disconnect devices
⎯
3.4.9
Plugs as disconnect devices
⎯
3.4.10 Interconnected
equipment
⎯
3.4.11
Multiple power sources
⎯
- Page 23 of 62 -
Report
No. 111798
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
3.5
Interconnection of equipment
⎯
3.5.1 General
requirements
Considered.
⎯
3.5.2
Types of interconnection circuits ..........................: SELV
circuit.
P
3.5.3
ELV circuits as interconnection circuits
No ELV.
N
3.5.4
Data ports for additional equipment
The equipment powered by
Limited Power Source.
Limited Power Source.
P
Measuring instrument
Inv. no.
Date
4 PHYSICAL
REQUIREMENTS
⎯
4.1 Stability
⎯
Angle of 10
°
<7kg N
Test force (N) ........................................................ : The
unit
is not floor-standing.
N
Measuring instrument
Inv. no.
Date
4.2 Mechanical
strength
⎯
4.2.1
General
Class III equipment.
N
4.2.2
Steady force test, 10 N
N
4.2.3
Steady force test, 30 N
N
4.2.4
Steady force test, 250 N
N
4.2.5 Impact
test
N
Fall
test
N
Swing
test
N
4.2.6
Drop test; height (mm) .......................................... :
N
4.2.7
Stress relief test
N
- Page 24 of 62 -
Report
No. 111798
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
4.2.8
Cathode ray tubes
CRT(s) not used in the
equipment.
equipment.
N
Picture tube separately certified ............................ :
⎯
4.2.9
High pressure lamps
No high pressure lamps in the
equipment.
equipment.
N
4.2.10
Wall or ceiling mounted equipment; force (N) ....... :
Not intended to be mounted on
a wall or ceiling.
a wall or ceiling.
N
Measuring instrument
Inv. no.
Date
4.3
Design and construction
⎯
4.3.1
Edges and corners
All edges and corners are
rounded and/or smoothed.
rounded and/or smoothed.
P
4.3.2
Handles and manual controls; force (N) .............:
No knobs, grips, handles, lever
etc that might create hazard.
etc that might create hazard.
N
4.3.3
Adjustable controls
No hazardous adjustable
controls.
controls.
N
4.3.4
Securing of parts
No loosening of parts impairing
creepage distances or
clearances is likely to occur.
creepage distances or
clearances is likely to occur.
P
4.3.5
Connection by plugs and sockets
SELV connectors do not
comply with IEC 60320 or IEC
60083.
comply with IEC 60320 or IEC
60083.
P
4.3.6
Direct plug-in equipment
Not intended to plug directly
into a wall socket-outlet.
into a wall socket-outlet.
N
Torque
.................................................................. :
⎯
Compliance with the relevant mains plug standard
N
4.3.7
Heating elements in earthed equipment
No heating elements provided.
N
4.3.8
Batteries
No batteries in the equipment.
N
- Overcharging of a rechargeable battery
N