JBL DUET 200 (serv.man3) EMC - CB Certificate ▷ View online
- Page 25 of 62 -
Report
No. 111798
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
- Unintentional charging of a non-rechargeable
battery
battery
N
- Reverse charging of a rechargeable battery
N
- Excessive discharging rate for any battery
N
4.3.9
Oil and grease
Insulation is not exposed to oil,
grease etc.
grease etc.
N
4.3.10
Dust, powders, liquids and gases
The equipment does not
generate ionizing radiation or
use a laser, and does not
contain flammable liquids or
gases.
generate ionizing radiation or
use a laser, and does not
contain flammable liquids or
gases.
N
4.3.11
Containers for liquids or gases
No containers for liquids or
gases in the equipment.
gases in the equipment.
N
4.3.12 Flammable
liquids
................................................ : The
equipment does not
contain flammable liquid.
N
Quantity of liquid (l) .............................................. :
N
Flash point (
°C) .................................................... :
N
4.3.13 Radiation
Refer
below:
⎯
4.3.13.1 General
Refer
below:
⎯
4.3.13.2 Ionizing
radiation
The equipment does not
generate ionizing radiation.
generate ionizing radiation.
N
Measured
radiation (pA/kg) .................................. :
⎯
Measured
high-voltage (kV) ................................. :
⎯
Measured focus voltage (kV) ............................... :
⎯
CRT
markings ...................................................... :
⎯
4.3.13.3 Effect of ultraviolet (UV) radiation on materials
The equipment does not
produce significant UV
radiation.
produce significant UV
radiation.
N
Part, property, retention after test, flammability
classification ......................................................... :
classification ......................................................... :
N
4.3.13.4 Human exposure to ultraviolet (UV) radiation ...... :
The equipment does not
produce significant UV
radiation.
produce significant UV
radiation.
N
4.3.13.5 Laser (including LEDs)
Diffuse LEDs only.
N
Laser
class
........................................................... :
⎯
- Page 26 of 62 -
Report
No. 111798
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
4.3.13.6 Other
types ........................................................... :
The equipment does not
generate other types of
radiation.
generate other types of
radiation.
N
Measuring instrument
Inv. no.
Date
4.4
Protection against hazardous moving parts
⎯
4.4.1
General
No moving parts.
N
4.4.2
Protection in operator access areas ....................: No
moving parts.
N
4.4.3
Protection in restricted access locations ..............:
Not intended for installation in
RAL.
RAL.
N
4.4.4
Protection in service access areas
Unintentional contact is not
likely in service accoess areas.
likely in service accoess areas.
N
Measuring instrument
Inv. no.
Date
4.5 Thermal
requirements
⎯
4.5.1 General
See
below.
⎯
4.5.2 Temperature
tests
(See appended table 4.5.)
P
Normal load condition per Annex L ......................:
⎯
4.5.3
Temperature limits for materials
(see appended table 4.5)
P
4.5.4
Touch temperature limits
(see appended table 4.5)
P
4.5.5 Resistance
to
abnormal heat ...............................:
N
Measuring instrument
Inv. no.
Date
- Page 27 of 62 -
Report
No. 111798
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
4.6
Openings in enclosures
⎯
4.6.1
Top and side openings
No top and side openings.
Unit is supplied with LPS and
class III equipment.
Unit is supplied with LPS and
class III equipment.
N
Dimensions
(mm) ................................................ :
⎯
4.6.2
Bottoms of fire enclosures
No bottom openings.
Unit is supplied with LPS.
Unit is supplied with LPS.
N
Construction of the bottomm, dimensions (mm) . :
⎯
4.6.3
Doors or covers in fire enclosures
No doors or covers in fire
enclosure.
enclosure.
N
4.6.4
Openings in transportable equipment
The unit is not regarded as
transportable equipment.
transportable equipment.
N
4.6.4.1
Constructional design measures
N
Dimensions
(mm) ................................................ :
⎯
4.6.4.2
Evaluation measures for larger openings
N
4.6.4.3
Use of metallized parts
N
4.6.5
Adhesives for constructional purposes
No barrier secured by adhesive
inside enclosure.
inside enclosure.
N
Conditioning temperature (
°C), time (weeks) ....... :
⎯
Measuring instrument
Inv. no.
Date
4.7
Resistance to fire
⎯
4.7.1
Reducing the risk of ignition and spread of flame
Equipment is class III
equipment, powered from a
LPS.
equipment, powered from a
LPS.
P
Method 1, selection and application of components
wiring and materials
wiring and materials
Equipment is class III
equipment, powered from a
LPS.
equipment, powered from a
LPS.
P
Method 2, application of all of simulated fault
condition tests
condition tests
N
- Page 28 of 62 -
Report
No. 111798
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
4.7.2
Conditions for a fire enclosure
Equipment is class III equipment,
powered from a LPS. Fire
enclosure is not considered
necessary.
powered from a LPS. Fire
enclosure is not considered
necessary.
N
4.7.2.1
Parts requiring a fire enclosure
Refer to 4.7.2.
N
4.7.2.2
Parts not requiring a fire enclosure
Equipment is class III powered
from a LPS. Additionally all
components are mounted on V-1
or better material.
from a LPS. Additionally all
components are mounted on V-1
or better material.
P
4.7.3 Materials
⎯
4.7.3.1
General
Components and materials
have adequate flammability
classification. See appended
table 1.5.1.
have adequate flammability
classification. See appended
table 1.5.1.
P
4.7.3.2
Materials for fire enclosures
Fire enclosure not required, refer
to 4.7.2.
to 4.7.2.
N
4.7.3.3
Materials for components and other parts outside fire
enclosures
enclosures
Fire enclosure not required, refer
to 4.7.2.
to 4.7.2.
N
4.7.3.4
Materials for components and other parts inside fire
enclosures
enclosures
Fire enclosure not required, refer
to 4.7.2.
to 4.7.2.
N
4.7.3.5
Materials for air filter assemblies
No air filters in the equipment.
N
4.7.3.6
Materials used in high-voltage components
No parts exceeding 4kV.
N
Measuring instrument
Inv. no.
Date
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
⎯
5.1
Touch current and protective conductor current
⎯
5.1.1
General
Class III equipment. Unit is not
intended for direct connection
to a mains supply. No test
considered necessary.
intended for direct connection
to a mains supply. No test
considered necessary.
N
5.1.2
Configuration of equipment under test (EUT)
N
5.1.2.1
Single connection to an a.c. mains supply
N
Click on the first or last page to see other DUET 200 (serv.man3) service manuals if exist.