DOWNLOAD JBL DUET 200 (serv.man3) Service Manual ↓ Size: 424.93 KB | Pages: 62 in PDF or view online for FREE

Model
DUET 200 (serv.man3)
Pages
62
Size
424.93 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
duet-200-sm3.pdf
Date

JBL DUET 200 (serv.man3) EMC - CB Certificate ▷ View online

 
 
- Page 25 of 62 - 
 
 
 Report 
No. 111798 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
 
- Unintentional charging of a non-rechargeable 
battery 
 N 
 
- Reverse charging of a rechargeable battery 
 
 
- Excessive discharging rate for any battery 
 
4.3.9 
Oil and grease 
Insulation is not exposed to oil, 
grease etc. 
4.3.10 
Dust, powders, liquids and gases 
The equipment does not 
generate ionizing radiation or 
use a laser, and does not 
contain flammable liquids or 
gases. 
4.3.11 
Containers for liquids or gases 
No containers for liquids or 
gases in the equipment. 
4.3.12 Flammable 
liquids 
................................................ : The 
equipment does not 
contain flammable liquid. 
 
Quantity of liquid (l)  .............................................. :  
 
Flash point (
°C) .................................................... : 
 N 
4.3.13 Radiation 
Refer 
below: 
⎯ 
4.3.13.1 General 
Refer 
below: 
⎯ 
4.3.13.2 Ionizing 
radiation  
The equipment does not 
generate ionizing radiation. 
 Measured 
radiation (pA/kg) .................................. : 
 
⎯ 
 Measured 
high-voltage (kV) ................................. : 
 
⎯ 
 
Measured focus voltage (kV) ............................... : 
 
⎯ 
 CRT 
markings ...................................................... : 
 
⎯ 
4.3.13.3  Effect of ultraviolet (UV) radiation on materials 
The equipment does not 
produce significant UV 
radiation. 
 
Part, property, retention after test, flammability 
classification ......................................................... : 
 N 
4.3.13.4  Human exposure to ultraviolet (UV) radiation ...... : 
The equipment does not 
produce significant UV 
radiation. 
4.3.13.5  Laser (including LEDs) 
Diffuse LEDs only. 
 Laser 
class 
........................................................... : 
 
⎯ 
 
 
- Page 26 of 62 - 
 
 
 Report 
No. 111798 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
4.3.13.6 Other 
types ........................................................... : 
The equipment does not 
generate other types of 
radiation. 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
4.4 
Protection against hazardous moving parts 
⎯ 
4.4.1 
General 
No moving parts. 
4.4.2 
Protection in operator access areas  ....................: No 
moving parts. 
4.4.3 
Protection in restricted access locations ..............: 
Not intended for installation in 
RAL. 
4.4.4 
Protection in service access areas 
Unintentional contact is not 
likely in service accoess areas.
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
4.5 Thermal 
requirements 
⎯ 
4.5.1 General 
See 
below. 
⎯ 
4.5.2 Temperature 
tests 
(See appended table 4.5.) 
 
Normal load condition per Annex L ......................: 
 
⎯ 
4.5.3 
Temperature limits for materials 
(see appended table 4.5) 
4.5.4 
Touch temperature limits 
(see appended table 4.5) 
4.5.5 Resistance 
to 
abnormal heat  ...............................:  
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
 
 
- Page 27 of 62 - 
 
 
 Report 
No. 111798 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
4.6 
Openings in enclosures 
⎯ 
4.6.1 
Top and side openings 
No top and side openings. 
Unit is supplied with LPS and 
class III equipment. 
 Dimensions 
(mm) ................................................ : 
 
⎯ 
4.6.2 
Bottoms of fire enclosures 
No bottom openings.  
Unit is supplied with LPS. 
 
Construction of the bottomm, dimensions (mm)  . : 
 
⎯ 
4.6.3 
Doors or covers in fire enclosures 
No doors or covers in fire 
enclosure. 
4.6.4 
Openings in transportable equipment 
The unit is not regarded as 
transportable equipment. 
4.6.4.1 
Constructional design measures 
 
 Dimensions 
(mm) ................................................ : 
 
⎯ 
4.6.4.2 
Evaluation measures for larger openings 
 
4.6.4.3 
Use of metallized parts 
 
4.6.5 
Adhesives for constructional purposes 
No barrier secured by adhesive
inside enclosure. 
 
Conditioning temperature (
°C), time (weeks) ....... : 
 
⎯ 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
4.7 
Resistance to fire 
⎯ 
4.7.1 
Reducing the risk of ignition and spread of flame 
Equipment is class III 
equipment, powered from a 
LPS. 
 
Method 1, selection and application of components 
wiring and materials 
Equipment is class III 
equipment, powered from a 
LPS. 
 
Method 2, application of all of simulated fault 
condition tests 
 
 
 
- Page 28 of 62 - 
 
 
 Report 
No. 111798 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
4.7.2 
Conditions for a fire enclosure 
Equipment is class III equipment,
powered from a LPS. Fire 
enclosure is not considered 
necessary.
 
4.7.2.1 
Parts requiring a fire enclosure 
Refer to 4.7.2.
 
4.7.2.2 
Parts not requiring a fire enclosure 
Equipment is class III powered 
from a LPS. Additionally all 
components are mounted on V-1
or better material.
 
4.7.3 Materials 
⎯ 
4.7.3.1 
General 
Components and materials 
have adequate flammability 
classification. See appended 
table 1.5.1. 
4.7.3.2 
Materials for fire enclosures 
Fire enclosure not required, refer
to 4.7.2.
 
4.7.3.3 
Materials for components and other parts outside fire 
enclosures 
Fire enclosure not required, refer
to 4.7.2.
 
4.7.3.4 
Materials for components and other parts inside fire 
enclosures 
Fire enclosure not required, refer
to 4.7.2.
 
4.7.3.5 
Materials for air filter assemblies 
No air filters in the equipment.
4.7.3.6 
Materials used in high-voltage components 
No parts exceeding 4kV. 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 
 
5.1 
Touch current and protective conductor current 
⎯ 
5.1.1 
General 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. No test 
considered necessary. 
5.1.2 
Configuration of equipment under test (EUT) 
 
5.1.2.1 
Single connection to an a.c. mains supply 
 
Page of 62
Display