- Page 45 of 62 - 
 
 
 Report 
No. 111798 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
3.2.1.1 
In Ireland, apparatus which is fitted with a flexible cable or cord and is designed to 
be connected to a mains socket conforming to I.S. 411 by means of that flexible 
cable or cord and plug, shall be fitted with a 13 A plug in accordance with Statutory 
Instrument 525:1997 - National Standards Authority of Ireland (section 28) (13 A 
Plugs and Conversion Adaptors for Domestic Use) Regulations 1997. 
3.2.4 
In Switzerland, for requirements see 3.2.1.1 of this annex. 
3.2.5.1 
In the United Kingdom, a power supply cord with conductor of 1,25 mm2 is allowed
for equipment with a rated current over 10 A and up to and including 13 A. 
3.3.4 
In the United Kingdom, the range of conductor sizes of flexible cords to be 
accepted by terminals for equipment with a RATED CURRENT of over 10 A up to 
and including 13 A is: 
• 1,25 mm
2
 to 1,5 mm
2
 nominal cross-sectional area. 
4.3.6 
In the United Kingdom, the torque test is performed using a socket outlet complying
with BS 1363 part 1:1995, including Amendment 1:1997 and Amendment 2:2003 
and the plug part of DIRECT PLUG-IN EQUIPMENT shall be assessed to BS 1363: 
Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.13, 12.16 and 12.17, except that the 
test of 12.17 is performed at not less than 125 °C. Where the metal earth pin is 
replaced by an Insulated Shutter Opening Device (ISOD), the requirements of 
clauses 22.2 and 23 also apply. 
4.3.6 
In Ireland, DIRECT PLUG-IN EQUIPMENT is known as plug similar devices. Such 
devices shall comply with Statutory Instrument 526:1997 - National Standards 
Authority of Ireland (Section 28) (Electrical plugs, plug similar devices and sockets 
for domestic use) Regulations, 1997. 
5.1.7.1 
In FinlandNorway and Sweden TOUCH CURRENT measurement results 
exceeding 3,5 mA r.m.s. are permitted only for the following equipment: 
• STATIONARY PLUGGABLE EQUIPMENT TYPE A that  
 
○ 
is intended to be used in a RESTRICTED ACCESS LOCATION where
 
 
equipotential bonding has been applied, for example, in a  
  telecommunication 
centre; 
and 
 
○ 
has provision for a permanently connected PROTECTIVE EARTHING 
  CONDUCTOR; 
and 
 
○ 
is provided with instructions for the installation of that conductor by a 
  SERVICE 
PERSON; 
• STATIONARY PLUGGABLE EQUIPMENT TYPE B; 
• STATIONARY PERMANENTLY CONNECTED EQUIPMENT. 
 
 
- Page 46 of 62 - 
 
 
 Report 
No. 111798 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
6.1.2.1 
In FinlandNorway and Sweden, add the following text between the first and 
second paragraph of the compliance clause: 
If this insulation is solid, including insulation forming part of a component, it shall at 
least consist of either 
two layers of thin sheet material, each of which shall pass the electric  
 
strength test below, or 
one layer having a distance through insulation of at least 0,4 mm, which shall 
 
pass the electric strength test below. 
If this insulation forms part of a semiconductor component (e.g. an optocoupler), 
there is no distance through insulation requirement for the insulation consisting of an
insulating compound completely filling the casing, so that CLEARANCES and 
CREEPAGE DISTANCES do not exist, if the component passes the electric strength
test in accordance with the compliance clause below and in addition 
passes the tests and inspection criteria of 2.10.11 with an electric strength  
 
test of 1,5 kV multiplied by 1,6 (the electric strength test of 2.10.10 shall be  
 
performed using 1,5 kV), and 
is subject to ROUTINE TESTING for electric strength during manufacturing, 
 
using a test voltage of 1,5 kV. 
It is permitted to bridge this insulation with a capacitor complying with 
EN 132400:1994, subclass Y2. 
A capacitor classified Y3 according to EN 132400:1994, may bridge this insulation 
under the following conditions: 
the insulation requirements are satisfied by having a capacitor classified Y3 
 
as defined by EN 132400, which in addition to the Y3 testing, is tested with  
 
an impulse test of 2,5 kV defined in EN 60950-1:2006, 6.2.2.1; 
the additional testing shall be performed on all the test specimens as  
 
described in EN 132400; 
the impulse test of 2,5 kV is to be performed before the endurance test in 
 
EN 132400, in the sequence of tests as described in EN 132400. 
6.1.2.2 
In FinlandNorway and Sweden, the exclusions are applicable for 
PERMANENTLY CONNECTED EQUIPMENT, PLUGGABLE EQUIPMENT TYPE B 
and equipment intended to be used in a RESTRICTED ACCESS LOCATION where 
equipotential bonding has been applied, e.g. in a telecommunication centre, and 
which has provision for a permanently connected PROTECTIVE EARTHING 
CONDUCTOR and is provided with instructions for the installation of that conductor 
by a SERVICE PERSON. 
 
 
- Page 47 of 62 - 
 
 
 Report 
No. 111798 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
7.2 
In FinlandNorway and Sweden, for requirements see 6.1.2.1 and 6.1.2.2 of this 
annex. 
The term TELECOMMUNICATION NETWORK in 6.1.2 being replaced by the term 
CABLE DISTRIBUTION SYSTEM. 
7.3 
In Norway and Sweden, there are many buildings where the screen of the coaxial 
cable is normally not connected to the earth in the building installation. 
7.3 
In Norway, for installation conditions see EN 60728-11:2005. 
 
ZC A-DEVIATIONS 
(informative) 
⎯ 
1.5.1 
Sweden
 (Ordinance 1990:944) 
Add the following: 
NOTE In Sweden, switches containing mercury are not permitted. 
1.5.1 
Switzerland
 (Ordinance on environmentally hazardous substances SR 814.081, 
Annex 1.7, Mercury - Annex 1.7 of SR 814.81 applies for mercury.) 
Add the following: 
NOTE In Switzerland, switches containing mercury such as thermostats, relays and level 
controllers are not allowed. 
1.7.2.1 
Denmark
 (Heavy Current Regulations) 
Supply cords of CLASS I EQUIPMENT, which is delivered without a plug, must be 
provided with a visible tag with the following text: 
Vigtigt! 
Lederen med grøn/gul isolation 
må kun tilsluttes en klemme mærket 
 eller   
If essential for the safety of the equipment, the tag must in addition be provided with 
a diagram, which shows the connection of the other conductors, or be provided with 
the following text: 
“For tilslutning af de øvrige ledere, se medfølgende installationsvejledning.” 
1.7.2.1 
Germany
 (Gesetz über technische Arbeitsmittel und Verbraucherprodukte (Geräte- 
und Produktsicherheitsgesetz – GPSG) [Law on technical labour equipment and 
consumer products], of 6th January 2004, Section 2, Article 4, Clause (4), Item 2). 
If for the assurance of safety and health certain rules during use, amending or 
maintenance of a technical labour equipment or readymade consumer product are 
to be followed, a manual in German language has to be delivered when placing the 
product on the market. 
Of this requirement, rules for use even only by SERVICE PERSONS are not 
exempted. 
 
 
- Page 48 of 62 - 
 
 
 Report 
No. 111798 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
1.7.5 
Denmark
 (Heavy Current Regulations) 
With the exception of CLASS II EQUIPMENT provided with a socket outlet in 
accordance with the Heavy Current Regulations, Section 107-2-D1, Standard Sheet 
DK 1-4a, CLASS II EQUIPMENT shall not be fitted with socket-outlets for providing 
power to other equipment. 
1.7.13 
Switzerland 
(Ordinance on chemical hazardous risk reduction SR 814.81, Annex 
2.15 Batteries) 
Annex 2.15 of SR 814.81 applies for batteries. 
5.1.7.1 
Denmark 
(Heavy Current Regulations, Chapter 707, clause 707.4) 
TOUCH CURRENT measurement results exceeding 3,5 mA r.m.s. are permitted 
only for PERMANENTLY CONNECTED EQUIPMENT and PLUGGABLE 
EQUIPMENT TYPE B. 
 
Page of 62