JBL CONTROL 2.4G (serv.man9) EMC - CB Certificate ▷ View online
Registration number: «Registriernummer»-E-16
ETS PRODUCT SERVICE AG
STORKOWER STRASSE 38C-15526 REICHENWALDE B. BERLIN Page 40 of 50
Radio Noise Field Strength
Emission
Standard : EN 55013
Reg. no. : T6M20611-0001-E-16
Model no. : Control 2.4G
Date : 30.11.2006
Operator :
Class : B
Frequency range / Polarization
Antenna
Passed
Failed
Number of
rechecks
30 MHz - 200 MHz / vertical
HK 116
:
0
30 MHz - 200 MHz / horizontal
HK 116
:
0
200 MHz - 1000 MHz /vertical
HL 223
:
0
200 MHz - 1000 MHz / horizontal
HL 223
:
0
Comment :.
Temperature : 22 °C
Pressure
: 1010 hPa
Rel. humidity : 40 %
Registration number: «Registriernummer»-E-16
ETS PRODUCT SERVICE AG
STORKOWER STRASSE 38C-15526 REICHENWALDE B. BERLIN Page 41 of 50
Current Harmonics
Harmonics
Standard : EN 61000 - 3 - 2
Reg.-no. : T6M20611-0001-E-16
Device : Control 2.4G
Date : 30.11.2006
Operator :
Class : A
Harmonic order
(n)
Max. permissible
harmonic current (A)
3 2,3
5 1,14
7 0,77
9 0,40
15 < n < 40
0,15 x 15/n
Comment: The power of the EUT ≤ 75 W. EUT is deemed to fulfill all requirements. Applicable to
AC/DC adaptor only.
Passed : yes / no
Temperature : 22 °C
Pressure
: 1004 hPa
Rel. humidity : 40 %
Registration number: «Registriernummer»-E-16
ETS PRODUCT SERVICE AG
STORKOWER STRASSE 38C-15526 REICHENWALDE B. BERLIN Page 42 of 50
Voltage Fluctuation
Flicker
Standard : EN 61000 - 3 - 3
Reg.-no. : T6M20611-0001-E-16
Device : Control 2.4G
Date : 30.11.2006
Operator :
P
st
pass
P
lt
< 0,65
pass
dc < 3,3%
pass
dt < 3,3%
pass
d max (%)
pass
Comment: Applicable to AC/DC adaptor only.
Passed : yes / no
Opinion :
Temperature : 22 °C
Pressure
: 1004 hPa
Rel. humidity : 40 %
Registration number: «Registriernummer»-E-16
ETS PRODUCT SERVICE AG
STORKOWER STRASSE 38C-15526 REICHENWALDE B. BERLIN Page 43 of 50
Electrostatic Discharge
ESD
Standard : EN 61000 - 4 - 2
Reg.-no. : T6M20611-0001-E-16
Device : Control 2.4G
Date : 30.11.2006
Operator :
Test point
Table (T)
Floor (F)
Floor (F)
Contact (C)
Air (A)
Air (A)
Voltage
(kV)
Number of
discharge
Polarity
( + / - )
Opinion
Housing
T
A
2, 4, 8
20
+ / -
Housing
T
C
2, 4
20
+ / -
Indirect
T
C
2, 4
20
+ / -
Opinion :
A
: No loss of performance or function
B
: Temporary loss of function or performance which is self-recoverable
C
: Temporary loss of function or perform. which req. operat. intervention or system reset
D
: Loss of function which is not recoverable
Temperature : 22 °C
Pressure
: 1004 hPa
Rel. humidity : 40 %
Click on the first or last page to see other CONTROL 2.4G (serv.man9) service manuals if exist.