DOWNLOAD JBL CONTROL 2.4G (serv.man9) Service Manual ↓ Size: 450.52 KB | Pages: 52 in PDF or view online for FREE

Model
CONTROL 2.4G (serv.man9)
Pages
52
Size
450.52 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
control-24g-sm9.pdf
Date

JBL CONTROL 2.4G (serv.man9) EMC - CB Certificate ▷ View online

 
Registration number: «Registriernummer»-E-16 
ETS PRODUCT SERVICE AG 
 
STORKOWER STRASSE 38C-15526 REICHENWALDE B. BERLIN  Page 36 of 50 
 
 
RF – Field according to 
EN 55020 
 
 
 
 
 
1 – metallic cover plate (2m x 0,6m) parallel to 
2 – metallic base plate (2m x 0,9m) 
3 – plastic supports 
4 – non metallic pedestal 
5 – Equipment under test 
6 – connector for generator and network 
7 – connector for terminating impedance 
 
 
1
2
3
3
3
3
4
5
6
7
 
Registration number: «Registriernummer»-E-16 
ETS PRODUCT SERVICE AG 
 
STORKOWER STRASSE 38C-15526 REICHENWALDE B. BERLIN  Page 37 of 50 
2.4 
EMC Test Results 
 
 
Conducted Emission 
38
 
Line Conducted Emission 
38
 
Radiated Emission 
40
 
Current Harmonics 
41
 
Flicker 
42
 
ESD 
43
 
RF-Field 
44
 
Electrical Fast Transients 
46
 
Immunity Conducted Voltages S2 
47
 
Immunity radiated Fields S3 
48
 
 
 
Registration number: «Registriernummer»-E-16 
ETS PRODUCT SERVICE AG 
 
STORKOWER STRASSE 38C-15526 REICHENWALDE B. BERLIN  Page 38 of 50 
 
 
 
Conducted Emission 
Emission
 
 
Standard  : EN 55013 
Reg.-no. : T6M20611-0001-E-16 
Device : Control 2.4G 
Date : 30.11.2006 
Operator : 
 
 
Class : B 
 
 
Frequency Range  
 
 
 
 
Network 
 
Passed 
 
Failed 
 
 
Number of 
rechecks 
 
150 kHz - 30 MHz 
 
R & S 
 
 
…  
 
 
 
Comment: Applicable to AC/DC adaptor only. 
 
 
 
 
 
  Temperature  :   22  °C
 
 Pressure 
: 1004 hPa 
  Rel. humidity :   40  % 
 
Registration number: «Registriernummer»-E-16 
ETS PRODUCT SERVICE AG 
 
STORKOWER STRASSE 38C-15526 REICHENWALDE B. BERLIN  Page 39 of 50 
 
Line Conducted Emission
 
- Absorbing Clamp - 
Emission
 
 
Standard  : EN 55013 
Reg.-no. : T6M20611-0001-E-16  
Device : Control 2.4G 
Date : 30.11.2006 
Operator : 
 
 
Class : B 
 
 
 
 
 
Frequency Range  
 
 
 
 
Absorbing Clamp 
 
Passed 
 
Failed 
 
 
Number of 
rechecks 
 
30 MHz - 300 MHz 
 
R & S MDS 21 
 
 
…  
 
 
 
 
Comment: Applicable to AC/DC adaptor only. 
 
  Temperature  :   22  °C
 
 Pressure 
: 1004 hPa 
  Rel. humidity :   40  % 
Page of 52