JBL CONTROL 2.4G (serv.man9) EMC - CB Certificate ▷ View online

 
Registration number: «Registriernummer»-E-16 
ETS PRODUCT SERVICE AG 
 
STORKOWER STRASSE 38C-15526 REICHENWALDE B. BERLIN  Page 24 of 50 
Harmonic Current Emission /Voltage Fluctuations and Flicker (EN 61000-3-2/-3) 
 
Test Equipment 
 
a)  ECAT Test system 
  For your reference please find it in our test equipment list at page 9 to 17 as number : 53 to 63. 
b) PC system 
  For your reference please find it in our test equipment list at page 9 to 17 as number : 82. 
c) Software 
  Application software Vers. 1.21d 
 
 
 
Test Procedures 
 
 
• Test configuration 
 
The test configuration is correspondence to the standard EN 61000-3-2/-3. The equipment under 
test is placed on a wooden table with a height of 0,8m in the EMC lab. 
 
 
• Test parameters and marginal conditions 
 
The harmonic test is carried out in according the classification A, B, C, D of the standard EN 
61000-3-2 /2/. The flicker test is carried out in according the time interval of the standard EN 
61000-3-3 /3/. Both tests are carried out with above mentioned equipment with 230V and 50 Hz 
(see Picture 6). Further information please find in test protocol.
 
Registration number: «Registriernummer»-E-16 
ETS PRODUCT SERVICE AG 
 
STORKOWER STRASSE 38C-15526 REICHENWALDE B. BERLIN  Page 25 of 50 
 
 
 
 
 
Picture 6 
 
S
supply source
M
measuring equipment
EUT
equipment under test
U
test voltage
Z
input  impedance of the measuring equipment
Z
internal impedance of the supply  source
I
upper shrinkage  portion of the conduction current order 
G
open-circuit voltage of the supply source
M
S
n
S
U
Z
s
M
Z
M
I
N
~
EUT
G
Current Harmonics and Flicker
 according to
 EN 61000 - 3 - 2,
EN 61000 - 3 - 3 
 
Registration number: «Registriernummer»-E-16 
ETS PRODUCT SERVICE AG 
 
STORKOWER STRASSE 38C-15526 REICHENWALDE B. BERLIN  Page 26 of 50 
Electrostatic discharge  
 
 
 
 
Test equipment 
 
a) ESD Gun SESD 30000 
  For your reference please find it in our test equipment list at page 9 to 17 as number : 1. 
b) Power supply 
  For your reference please find it in our test equipment list at page 9 to 17 as number : 46 to 50. 
 
 
 
Test Procedures 
 
• Test configuration 
 
The test configuration corresponds to the standard EN 61000-4-2 /4/. The test setup shall consist of 
a wooden table, 0.8 m high, standing on the ground reference plane. A horizontal coupling plane, 
1.6 m x 0.8 m, shall be placed on the table. The EUT and cables shall be isolated from the HCP by 
an insulating support, 0.5 mm thick. Both metal plates are connected by two 470 k
Ω resistors in 
series. (see Picture 7) 
 
 
• Test parameters and marginal conditions 
 
The test is carried out with ±2kV, ±4kV and ±6kV contact discharge and ±2kV, ±4kV and ±8kV air 
discharge. The tested points are mentioned in the test protocol. 
 
 
 
Registration number: «Registriernummer»-E-16 
ETS PRODUCT SERVICE AG 
 
STORKOWER STRASSE 38C-15526 REICHENWALDE B. BERLIN  Page 27 of 50 
 
 
Electrostatic Discharge according 
to EN 61000 – 4 – 2 
 
 
 
 
 
Picture 7
 
 
Page of 52
Display