JBL CONTROL 2.4G (serv.man9) EMC - CB Certificate ▷ View online
Registration number: «Registriernummer»-E-16
ETS PRODUCT SERVICE AG
STORKOWER STRASSE 38C-15526 REICHENWALDE B. BERLIN Page 24 of 50
Harmonic Current Emission /Voltage Fluctuations and Flicker (EN 61000-3-2/-3)
Test Equipment
a) ECAT Test system
For your reference please find it in our test equipment list at page 9 to 17 as number : 53 to 63.
b) PC system
For your reference please find it in our test equipment list at page 9 to 17 as number : 82.
c) Software
Application software Vers. 1.21d
Test Procedures
• Test configuration
The test configuration is correspondence to the standard EN 61000-3-2/-3. The equipment under
test is placed on a wooden table with a height of 0,8m in the EMC lab.
• Test parameters and marginal conditions
The harmonic test is carried out in according the classification A, B, C, D of the standard EN
61000-3-2 /2/. The flicker test is carried out in according the time interval of the standard EN
61000-3-3 /3/. Both tests are carried out with above mentioned equipment with 230V and 50 Hz
(see Picture 6). Further information please find in test protocol.
Test Equipment
a) ECAT Test system
For your reference please find it in our test equipment list at page 9 to 17 as number : 53 to 63.
b) PC system
For your reference please find it in our test equipment list at page 9 to 17 as number : 82.
c) Software
Application software Vers. 1.21d
Test Procedures
• Test configuration
The test configuration is correspondence to the standard EN 61000-3-2/-3. The equipment under
test is placed on a wooden table with a height of 0,8m in the EMC lab.
• Test parameters and marginal conditions
The harmonic test is carried out in according the classification A, B, C, D of the standard EN
61000-3-2 /2/. The flicker test is carried out in according the time interval of the standard EN
61000-3-3 /3/. Both tests are carried out with above mentioned equipment with 230V and 50 Hz
(see Picture 6). Further information please find in test protocol.
Registration number: «Registriernummer»-E-16
ETS PRODUCT SERVICE AG
STORKOWER STRASSE 38C-15526 REICHENWALDE B. BERLIN Page 25 of 50
Picture 6
S
supply source
M
measuring equipment
EUT
equipment under test
U
test voltage
Z
input impedance of the measuring equipment
Z
internal impedance of the supply source
I
upper shrinkage portion of the conduction current order
G
open-circuit voltage of the supply source
M
S
n
S
U
Z
s
M
Z
M
I
N
~
EUT
G
Current Harmonics and Flicker
according to
EN 61000 - 3 - 2,
EN 61000 - 3 - 3
Registration number: «Registriernummer»-E-16
ETS PRODUCT SERVICE AG
STORKOWER STRASSE 38C-15526 REICHENWALDE B. BERLIN Page 26 of 50
Electrostatic discharge
Test equipment
a) ESD Gun SESD 30000
For your reference please find it in our test equipment list at page 9 to 17 as number : 1.
b) Power supply
For your reference please find it in our test equipment list at page 9 to 17 as number : 46 to 50.
Test Procedures
• Test configuration
The test configuration corresponds to the standard EN 61000-4-2 /4/. The test setup shall consist of
a wooden table, 0.8 m high, standing on the ground reference plane. A horizontal coupling plane,
1.6 m x 0.8 m, shall be placed on the table. The EUT and cables shall be isolated from the HCP by
an insulating support, 0.5 mm thick. Both metal plates are connected by two 470 k
Test equipment
a) ESD Gun SESD 30000
For your reference please find it in our test equipment list at page 9 to 17 as number : 1.
b) Power supply
For your reference please find it in our test equipment list at page 9 to 17 as number : 46 to 50.
Test Procedures
• Test configuration
The test configuration corresponds to the standard EN 61000-4-2 /4/. The test setup shall consist of
a wooden table, 0.8 m high, standing on the ground reference plane. A horizontal coupling plane,
1.6 m x 0.8 m, shall be placed on the table. The EUT and cables shall be isolated from the HCP by
an insulating support, 0.5 mm thick. Both metal plates are connected by two 470 k
Ω resistors in
series. (see Picture 7)
• Test parameters and marginal conditions
The test is carried out with ±2kV, ±4kV and ±6kV contact discharge and ±2kV, ±4kV and ±8kV air
discharge. The tested points are mentioned in the test protocol.
• Test parameters and marginal conditions
The test is carried out with ±2kV, ±4kV and ±6kV contact discharge and ±2kV, ±4kV and ±8kV air
discharge. The tested points are mentioned in the test protocol.
Registration number: «Registriernummer»-E-16
ETS PRODUCT SERVICE AG
STORKOWER STRASSE 38C-15526 REICHENWALDE B. BERLIN Page 27 of 50
Electrostatic Discharge according
to EN 61000 – 4 – 2
Picture 7