DOWNLOAD Harman Kardon GPS 500 Service Manual ↓ Size: 1.34 MB | Pages: 82 in PDF or view online for FREE

Model
GPS 500
Pages
82
Size
1.34 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Car Audio
File
gps-500.pdf
Date

Harman Kardon GPS 500 EMC - CB Certificate ▷ View online

 
 
<11006065 001> 
 
 
Page 38 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
EN 132400:1994, may bridge this insulation 
under the following conditions: 
- the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by 
EN 132400, which in addition to the Y3 testing, is 
tested with an impulse test of 2,5 kV defined in 
EN 60950:2000, 6.2.2.1; 
- the additional testing shall be performed on all 
the test specimens as described in EN 132400; 
- the impulse test of 2,5 kV is to be performed 
before the endurance test in EN 132400, in the 
sequence of tests as described in EN 132400. 
6.1.2.2 
S (FI, NO, SE): The exclusions are applicable for 
PERMANENTLY CONNECTED EQUIPMENT
 and
 
PLUGGABLE EQUIPMENT TYPE 
B and equipment 
intended to be used in a 
RESTRICTED ACCESS 
LOCATION
 where equipotential bonding has been 
applied, e.g. in a telecommunication centre, and 
which has provision for a permanently connected 
PROTECTIVE EARTHING CONDUCTOR 
and is 
provided with instructions for the installation of 
that conductor by a service person. 
Ditto. 
7.1 
S (FI, NO, SE): Requirements according to this 
annex, 6.1.2.1 and 6.1.2.2 apply with the term 
TELECOMMUNICATION NETWORK
 in 6.1.2 being 
replaced by the term 
CABLE DISTRIBUTION SYSTEM
Ditto. 
G.2.1 
S (NO): Due to the IT power distribution system 
used (see annex V, Fig. V.7), the 
A
.
C
MAINS 
SUPPLY
 voltage is considered to be equal to the 
line-to-line voltage, and will remain at 230 V in 
case of a single earth fault. 
Annex G not applied for. 
Annex H 
C: Replace the last paragraph of this annex by: 
At any point 10 cm from the surface of the 
operator access area, the dose rate shall not 
exceed 1 
µ
Sv/h (0,1 mR/h) (see note). Account is 
taken of the background level. 
Replace the notes as follows: 
NOTE  These values appear in Directive 96/29/Euratom. 
 
Delete Note 2. 
Replaced. 
Annex P 
C: Replace the text of this annex by: 
See annex ZA. 
Replaced. 
Annex Q 
C: Replace the title of IEC 61032 by "Protection of persons and equipment by 
enclosures – Probes for verification". 
Add the following notes for the standards indicated: 
IEC 60127 
NOTE Harmonized as EN 60127 (Series) (not modified) 
IEC 60269-2-1 NOTE Harmonized as HD 630.2.1 S4:2000 (modified) 
 
 
<11006065 001> 
 
 
Page 39 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
IEC 60529 
NOTE Harmonized as EN 60529:1991 (not modified) 
IEC 61032 
NOTE Harmonized as EN 61032:1998 (not modified) 
IEC 61140 
NOTE Harmonized as EN 61140:2001 (not modified) 
ITU-T Recommendation K.31 
 
 
NOTE in Europe, the suggested document is EN 50083-1. 
 
 
<11006065 001> 
 
 
Page 40 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
Annex ZA  C: NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH 
THEIR RELEVANT EUROPEAN PUBLICATIONS 
This European Standard incorporates, by dated or undated reference, provisions 
from other publications. These normative references are cited at the appropriate 
places in the text and the publications are listed hereafter. For dated references, 
subsequent amendments to or revisions of any of these publications apply to this 
European Standard only when incorporated in it by amendment or revision. For 
undated references, the latest edition of the publication referrd to applies (including 
amendments). 
NOTE  When an international publication has been modified by common modifications, indicated by 
(mod), the relevant EN/HD applies. 
 
 
IEC 60050-151 
 
 
 
IEC 60050-195 
 
 
EN 60065:1998 + corr. June 1999 
IEC 60065 (mod):1998 
 
 
EN 60073:1996 
IEC 60073:1996 
 
 
HD 566 S1:1990 
IEC 60085:1984 
 
 
HD 214 S2:1980 
IEC 60112:1979 
 
 
HD 611.4.1.S1:1992 
IEC 60216-4-1:1990 
 
 
HD 21 
1)
 Series 
IEC 60227 (mod) Series 
 
 
HD 22 
2)
 Series 
IEC 60245 (mod) Series 
 
 
EN 60309 Series 
IEC 60309 Series 
 
 
EN 60317-43:1997 
IEC 60317-43:1997 
 
 
EN 60320 Series 
IEC 60320 (mod) Series 
 
 
HD 384.3 S2:1995 
IEC 60364-3 (mod):1993 
 
 
HD 384.4.41 S2:1996 
IEC 60364-4-41 (mod):1992 
3)
 
 
 
EN 132400:1994 
4)
  
+ A2:1998 + A3:1998 + A4:2001 
IEC 60384-14:1993 
 
 
EN 60417-1 
IEC 60417-1 
 
 
HD 625.1 S1:1996 + corr. Nov. 1996 
IEC 60664-1 (mod):1992 
 
 
EN 60695-2-2:1994 
IEC 60695-2-2:1991 
 
 
EN 60695-2-11:2001 
IEC 60695-2-11:2000 
 
 
 
IEC 60695-2-20:1995 
 
 
 
IEC 60695-10-2:1995 
 
 
 
IEC 60695-11-3:2000 
 
 
 
IEC 60695-11-4:2000 
 
 
EN 60695-11-10:1999 
IEC 60695-11-10:1999 
 
 
EN 60695-11-20:1999 
IEC 60695-11-20:1999 
 
 
EN 60730-1:2000 
IEC 60730-1:1999 (mod) 
 
 
EN 60825-1:1994 + corr. Febr. 1995 + 
A11:1996 + corr. July 1997 
IEC 60825-1:1993 
 
 
EN 60825-2:2000 
IEC 60825-2:2000 
 
 
 
IEC 60825-9:1999 
 
 
EN 60851-3:1996 
IEC 60851-3:1996 
 
 
 
<11006065 001> 
 
 
Page 41 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
EN 60851-5:1996 
IEC 60825-5:1996 
 
 
EN 60851-6:1996 
IEC 60851-6:1996 
 
 
 
IEC 60885-1:1987 
 
 
EN 60990:1999 
IEC 60990:1999 
 
 
 
IEC 61058-1:2000 
 
 
EN 61965:2001 
IEC 61965:2000 
 
 
EN ISO 178:1996 
ISO 178:1993 
 
 
EN ISO 179 Series 
ISO 179 Series 
 
 
EN ISO 180:2000 
ISO 180:1993 
 
 
 
ISO 261:1998 
 
 
 
ISO 262:1998 
 
 
EN ISO 527 Series 
ISO 527 Series 
 
 
 
ISO 386:1984 
 
 
EN ISO 4892 Series 
ISO 4892 Series 
 
 
 
ISO 7000:1989 
 
 
EN ISO 8256:1996 
ISO 8256:1990 
 
 
 
ISO 9772:1994 
 
 
EN ISO 9773:1998 
ISO 9773:1998 
 
 
 
ITU-T:1988 Recommendation K.17 
 
 
 
ITU-T:2000 Recommendation K.21 
 
 
1) The HD 21 series is related to, but not directly equivalent with the IEC 60227 series 
2) The HD 22 series is related to, but not directly equivalent with the IEC 60245 series 
3) IEC 60364-4-41:1992 is superseded by IEC 60364-4-41:2001 
4) EN 132400, Sectional Specification: Fixed capacitors for electromagnetic interference suppression 
and connection to the supply mains (Assessment level D), and its amendments are related to, but not 
directly equivalent to IEC 60384-14 
 
 
Page of 82
Display