<11006065 001> 
 
 
Page 30 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
V.3 
TT power systems 
 
V.4 
IT power systems 
Shall be evaluated during 
national approval. 
 
ANNEX W, SUMMATION OF TOUCH CURRENTS  
W.1 
Touch current from electronic circuits 
 
W.1.2 
Earthed circuits 
 
W.2 
Interconnection of several equipments 
 
W.2.1 
Isolation 
 
W.2.2 
Common return, isolated from earth 
 
W.2.3 
Common return, connected to protective earth 
 
 
ANNEX X, MAXIMUM HEATING EFFECT IN TRANSRORMER TESTS 
(see clause C.1) 
X.1 
Determination of maximum input current  
 
X.2 
Overload test procedure 
 
 
ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3) 
Y.1 
Test apparatus  ................................................... : 
 
Y.2 
Mounting of test samples ................................... : 
 
Y.3 
Carbon-arc light-exposure apparatus  ................ : 
 
Y.4 
Xenon-arc light exposure apparatus .................. : 
 
 
 
<11006065 001> 
 
 
Page 31 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
CENELEC COMMON MODIFICATIONS [C], 
SPECIAL NATIONAL CONDITIONS [S] AND A-DEVIATIONS (NATIONAL DEVIATIONS) [A] 
(EN 60950-1:2001, Annex ZB and Annex ZC) 
General 
C: Delete all the "country" notes in the reference 
document according to the following list: 
1.1.5   Note 2 
1.5.8 
Note 2  1.6.1  Note  
1.7.2 
Note 4 
1.7.12 
Note 2  2.6 
Note 
2.2.3 
Note 
2.2.4 
Note 
2.3.2  Note 2, 7, 8 
2.3.3 
Note 1, 2  2.3.4 
Note 2,3  2.7.1  Note 
2.10.3.1 Note 4 
3.2.1.1  Note 
3.2.3  Note 1, 2 
3.2.5.1  Note 2 
4.3.6 
Note 1,2  4.7.2.2  Note 
4.7.3.1  Note 2 
6.1.2.1  Note 
6.1.2.2  Note 
6.2.2 
Note 
6.2.2.1  Note 2  6.2.2.2  Note 
Note 4 
7.1 
Note 
 
G2.1 
Note 1, 2  Annex H  Note 2 
Deleted. 
1.2.4.1 
S (DK): Certain types of Class I appliances (see 
3.2.1.1) may be provided with a plug not 
establishing earthing conditions when inserted 
into Danish socket-outlets. 
Class II equipment. 
1.5.1 
A (SE, Ordinance 1990:944 and  
CH, Ordinance on environmentally hazardous 
substances SR 814.013, Annex 3.2, Mercury): 
Add 
NOTE – Switches containing mercury such as 
thermostats, relays and level controllers are not allowed.
 
No such switches used. 
1.5.8 
S (NO): Due to the IT power system used (see 
annex V, Fig. V.7), capacitors are required to be 
rated for the applicable line-to-line voltage 
(230 V). 
Class II 
1.7.2 
S (FI, NO, SE): C
LASS 
PLUGGABLE EQUIPMENT 
TYPE 
A intended for connection to other 
equipment or a network shall, if safety relies on 
connection to protective earth or if surge 
suppressors are connected between the network 
terminals and accessible parts, have a marking 
stating that the equipment must be connected to 
an earthed mains socket-outlet. 
The marking text in the applicable countries shall 
be as follows: 
Class II equipment. 
 
FI: "Laite on liitettävä suojamaadoitus-
koskettimilla varustettuun pistorasiaan" 
Ditto. 
 
NO: "Apparatet må tilkoples jordet stikkontakt" 
Ditto. 
 
SE: "Apparaten skall anslutas till jordat uttag" 
Ditto. 
 
A (DK, Heavy Current Regulations): Supply cords 
of class I equipment, which is delivered without a 
plug, must be provided with a visible tag with the 
following text: 
Vigtigt! 
Lederen med grøn/gul isolation må kun tilsluttes 
en klemme mærket 
Ditto. 
 
 
<11006065 001> 
 
 
Page 32 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 eller  
  
If essential for the safety of the equipment, the 
tag must in addition be provided with a diagram 
which shows the connection of the other 
conductors, or be provided with the following text: 
"For tilslutning af de øvrige ledere, se 
medfølgende instalationsvejledning." 
1.7.5 
S (DK): Socket-outlets for providing power to 
other equipment shall be in accordance with the 
Heavy Current Regulations, Section 107-2-D1, 
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, 
when used on Class I equipment. For stationary 
equipment the socket-outlet shall be in 
accordance with Standard Sheet DK 1-1b or 
DK 1-5a. 
Class II equipment. 
1.7.5 
A (DK, Heavy Current Regulations): 
CLASS
 II 
EQUIPMENT
 shall not be fitted with socket-
outlets for providing power to other equipment. 
No socket-outlets provided. 
1.7.12 
A (DE, Gesetz über technische Arbeitsmittel 
(Gerätesicherheitsgesetz) [Law on technical 
labour equipment {Equipment safety law}], of 23
rd
 
October 1992, Article 3, 3
rd
 paragraph, 2
nd
 
sentence, together with the "Allgemeine 
Verwaltungsvorschrift zur Durchführung des 
Zweiten Abschnitts des Gerätesicherheits-
gesetzes" [General administrative regulation on 
the execution of the Second Section of the 
Equipment safety law], of 10
th
 January 1996, 
article 2, 4
th
 paragraph item 2): 
Directions for use with rules to prevent certain 
hazards for (among others) maintenance of the 
technical labour equipment, also for imported 
technical labour equipment shall be written in the 
German language. 
NOTE: Of this requirement, rules for use even only by 
service personnel are not exempted.  
User’s manual is provided in 
German. 
1.7.15 
A (CH, Ordinance on environmentally hazardous 
substances SR 814.013): 
Annex 4.10 of SR 814.013 applies for batteries. 
No batteries provided. 
 
A (DE, Regulation on protection against hazards 
by X-ray, of 8
th
 January 1987, Article 5 [Operation 
of X-ray emission source], clauses 1 to 4): 
a) A licence is required by those who operate an 
X-ray emission source. 
b) A licence in accordance with Cl. 1 is not 
required by those who operate an X-ray emission 
source on which the electron acceleration voltage 
does not exceed 20 kV if 
1) the local dose rate at a distance of 0,1 m from 
This national difference was 
deleted by A11 to EN 60950-1. 
 
 
<11006065 001> 
 
 
Page 33 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
the surface does not exceed 1  Sv/h and 
2) it is adequately indicated on the X-ray 
emission source that 
i)  X-rays are generated and 
ii)  the electron acceleration voltage must not 
exceed the maximum value stipulated by the 
manufacturer or importer. 
c) A licence in accordance with Cl. 1 is also not 
required by persons who operate an X-ray 
emission source on which the electron 
acceleration voltage exceeds 20 kV if 
1) the X-ray emission source has been granted a 
type approval and 
2) it is adequately indicated on the X-ray 
emission source that 
i)  X-rays are generated 
ii) the device stipulated by the manufacturer or 
importer guarantees that the maximum 
permissible local dose rate in accordance with 
the type approval is not exceeded and 
iii)  the electron acceleration voltage must not 
exceed the maximum value stipulated by the 
manufacturer or importer. 
d) Furthermore, a licence in accordance with 
Cl. 1 is also not required by persons who operate 
X-ray emission sources on which the electron 
acceleration voltage does not exceed 30 kV if 
1) the X-rays are generated only by intrinsically 
safe CRTs complying with Enclosure III, No. 6, 
2) the values stipulated in accordance with 
Enclosure III, No. 6.2 are limited by technical 
measures and specified in the device and 
3) it is adequately indicated on the X-ray 
emission source that the X-rays generated are 
adequately screened by the intrinsically safe 
CRT. 
2.2.4 
S (NO): Requirements according to this annex, 
1.7.2 and 6.1.2.1 apply. 
No TNV. 
2.3.2 
S (NO): Requirements according to this annex, 
6.1.2.1 apply. 
No TNV. 
2.3.3 and 
2.3.4 
S (NO): Requirements according to this annex, 
1.7.2 and 6.1.2.1 apply. 
No TNV. 
2.6.3.3 
S (GB): The current rating of the circuit shall be 
taken as 13 A, not 16 A. 
Not applied for. 
2.7.1 
C: Replace the subclause as follows: 
Replaced. 