TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
4.6.2
Bottoms of fire enclosures
Protection against emission of
flame, molten metal, flaming or
glowing particles or drop by fire
enclosure.
There are no openings at
There are no openings at
bottom of enclosure.
P
Construction of the bottom.................................. :
4.6.3
Doors or covers in fire enclosures
No doors or covers provided.
N
4.6.4
Openings in transportable equipment
No opening on whole enclosure.
P
4.6.5
Adhesives for constructional purposes
N
Conditioning temperature (
°
C)/time (weeks)....... :
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame Use of fire enclosure materials
with the required flammability
V-1 min..
P
Method 1, selection and application of
components wiring and materials
Ditto.
P
Method 2, application of all of simulated fault
condition tests
N
4.7.2
Conditions for a fire enclosure
See below.
P
4.7.2.1
Parts requiring a fire enclosure
With having the following parts:
components in primary
components in secondary
components in secondary
(not supplied by LPS)
insulated wiring
insulated wiring
the fire enclosure is required.
P
4.7.2.2
Parts not requiring a fire enclosure
See 4.7.2.1.
N
4.7.3
Materials
P
4.7.3.1
General
PCB rated V-0.
P
4.7.3.2
Materials for fire enclosures
Enclosure material rated V-1
min..
P
4.7.3.3
Materials for components and other parts outside
fire enclosures
Snap fit plug with plastic
material rated V-1 min.
P
4.7.3.4
Materials for components and other parts inside
fire enclosures
Internal components except
small parts are V-2 or better.
P
4.7.3.5
Materials for air filter assemblies
No air filter provided.
N
4.7.3.6
Materials used in high-voltage components
No high voltage components
provided.
N
<11006065 001>
Page 23 of 71
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
P
5.1
Touch current and protective conductor current
P
5.1.1
General
See sub-clauses 5.1.2 to 5.1.6.
P
5.1.2
Equipment under test (EUT)
EUT has only one mains
connection.
P
5.1.3
Test circuit
Equipment of figure 5A used.
P
5.1.4
Application of measuring instrument
Using measuring instrument in
annex D.
P
5.1.5
Test procedure
The touch current was
measured from mains to DC
output connector and to a 10 cm
×
20 cm metal foil wrapped on
accessible non-conductive parts
(plastic enclosure).
P
5.1.6
Test measurements
See below.
P
Test voltage (V) ..................................................: See appended table 5.1.6.
Measured touch current (mA) ............................: See appended table 5.1.6.
Max. allowed touch current (mA) .......................: See appended table 5.1.6.
Measured protective conductor current (mA) ....:
Max. allowed protective conductor current (mA).:
5.1.7
Equipment with touch current exceeding
3.5 mA ..............................................................:
Neither stationary permanently
connected equipment nor
stationary pluggable equipment
type B.
N
5.1.8
Touch currents to and from telecommunication
networks and cable distribution systems and from
telecommunication networks
No TNV circuit connection.
N
5.1.8.1
Limitation of the touch current to a
telecommunication network and a cable
distribution system
N
Test voltage (V) ..................................................:
Measured touch current (mA) ............................:
Max. allowed touch current (mA) .......................:
5.1.8.2
Summation of touch currents from
telecommunication networks ..............................:
N
5.2
Electric strength
P
5.2.1
General
See appended table 5.2.
P
5.2.2
Test procedure
See appended table 5.2.
P
5.3
Abnormal operating and fault conditions
P
<11006065 001>
Page 24 of 71
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
5.3.1
Protection against overload and abnormal
operation
Output overload test, the most
unfavourable load tested.
(See appended table 5.3).
(See appended table 5.3).
P
5.3.2
Motors
No motors.
N
5.3.3
Transformers
With the shorted and overload
o/p of the transformers, no high
temperature of the transformer
was recorded.
Results of the short-circuit tests
Results of the short-circuit tests
see appended table 5.3 and
Annex C.
P
5.3.4
Functional insulation ........................................... : Method c). Results see in
appended table 5.3.
P
5.3.5
Electromechanical components
No electromechanical
component provided.
N
5.3.6
Simulation of faults
Results see appended table
5.3.
P
5.3.7
Unattended equipment
None of the listed components
was provided.
N
5.3.8
Compliance criteria for abnormal operating and
fault conditions
Neither fire burns the equipment
nor molten metal was emitted.
Electric strength test primary
→
SELV, primary
→
plastic
enclosure were passed.
P
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
N
6.1.1
Protection from hazardous voltages
N
6.1.2
Separation of the telecommunication network from earth
N
6.1.2.1
Requirements
N
Test voltage (V) ..................................................:
Current in the test circuit (mA) .........................:
6.1.2.2
Exclusions...........................................................:
N
6.2
Protection of equipment users from overvoltages on telecommunication networks
N
6.2.1
Separation requirements
N
6.2.2
Electric strength test procedure
N
6.2.2.1
Impulse test
N
6.2.2.2
Steady-state test
N
6.2.2.3
Compliance criteria
N
<11006065 001>
Page 25 of 71
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
6.3
Protection of the telecommunication wiring system from overheating
N
Max. output current (A) ....................................... :
Current limiting method....................................... :
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N
7.1
Protection of cable distribution system service
persons, and users of other equipment
connected to the system, from hazardous
voltages in the equipment
N
7.2
Protection of equipment users from overvoltages
on the cable distribution system
N
7.3
Insulation between primary circuits and cable
distribution systems
N
7.3.1
General
N
7.3.2
Voltage surge test
N
7.3.3
Impulse test
N
A
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE
P
A.1
Flammability test for fire enclosures of movable equipment having a total mass
exceeding 18 kg, and of stationary equipment (see 4.7.3.2)
N
A.1.1
Samples .............................................................. :
Wall thickness (mm) ........................................... :
A.1.2
Conditioning of samples; temperature (
°
C)......... :
N
A.1.3
Mounting of samples........................................... :
N
A.1.4
Test flame (see IEC 60695-11-3)
N
Flame A, B, C or D ............................................. :
A.1.5
Test procedure
N
A.1.6
Compliance criteria
N
Sample 1 burning time (s)................................... :
Sample 2 burning time (s)................................... :
Sample 3 burning time (s)................................... :
A.2
Flammability test for fire enclosures of movable equipment having a total mass not
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)
UL approved material used with flammability class V-1 or better. No further tests
were considered.
P
A.2.1
Samples, material ............................................... :
Wall thickness (mm) ........................................... :