Page 22 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
4.6.2 
Bottoms of fire enclosures 
Protection against emission of 
flame, molten metal, flaming or 
glowing particles or drop by fire 
enclosure.  
There are no openings at 
bottom of enclosure. 
 
Construction of the bottom.................................. :   
 
4.6.3 
Doors or covers in fire enclosures 
No doors or covers provided. 
4.6.4 
Openings in transportable equipment 
No opening on whole enclosure. 
4.6.5 
Adhesives for constructional purposes 
 
 
Conditioning temperature (
°
C)/time (weeks)....... :   
 
 
4.7 
Resistance to fire 
4.7.1 
Reducing the risk of ignition and spread of flame  Use of fire enclosure materials 
with the required flammability 
V-1 min.. 
 
Method 1, selection and application of 
components wiring and materials 
Ditto. 
 
Method 2, application of all of simulated fault 
condition tests 
 
4.7.2 
Conditions for a fire enclosure 
See below. 
4.7.2.1 
Parts requiring a fire enclosure 
With having the following parts: 
components in primary 
components in secondary 
(not supplied by LPS) 
insulated wiring  
the fire enclosure is required. 
4.7.2.2 
Parts not requiring a fire enclosure 
See 4.7.2.1. 
4.7.3 
Materials 
4.7.3.1 
General 
PCB rated V-0. 
4.7.3.2 
Materials for fire enclosures 
Enclosure material rated V-1 
min.. 
4.7.3.3 
Materials for components and other parts outside 
fire enclosures 
Snap fit plug with plastic 
material rated V-1 min. 
4.7.3.4 
Materials for components and other parts inside 
fire enclosures 
Internal components except 
small parts are V-2 or better. 
4.7.3.5 
Materials for air filter assemblies 
No air filter provided. 
4.7.3.6 
Materials used in high-voltage components 
No high voltage components 
provided. 
 
 
 
<11006065 001> 
 
 
Page 23 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 
5.1 
Touch current and protective conductor current 
5.1.1 
General 
See sub-clauses 5.1.2 to 5.1.6. 
5.1.2 
Equipment under test (EUT) 
EUT has only one mains 
connection. 
5.1.3 
Test circuit 
Equipment of figure 5A used. 
5.1.4 
Application of measuring instrument 
Using measuring instrument in 
annex D. 
5.1.5 
Test procedure 
The touch current was 
measured from mains to DC 
output connector and to a 10 cm 
×
 20 cm metal foil wrapped on 
accessible non-conductive parts 
(plastic enclosure). 
5.1.6 
Test measurements 
See below. 
 
Test voltage (V) ..................................................:  See appended table 5.1.6. 
 
 
Measured touch current (mA)  ............................:  See appended table 5.1.6. 
 
 
Max. allowed touch current (mA)  .......................:  See appended table 5.1.6. 
 
 
Measured protective conductor current (mA)  ....:   
 
 
Max. allowed protective conductor current (mA).:   
 
5.1.7 
Equipment with touch current exceeding 
3.5 mA   ..............................................................: 
Neither stationary permanently 
connected equipment nor 
stationary pluggable equipment 
type B. 
5.1.8 
Touch currents to and from telecommunication 
networks and cable distribution systems and from 
telecommunication networks 
No TNV circuit connection. 
5.1.8.1 
Limitation of the touch current to a 
telecommunication network and a cable 
distribution system 
 
 
Test voltage (V) ..................................................:   
 
 
Measured touch current (mA)  ............................:   
 
 
Max. allowed touch current (mA)  .......................:   
 
5.1.8.2 
Summation of touch currents from 
telecommunication networks ..............................: 
 
 
5.2 
Electric strength 
5.2.1 
General 
See appended table 5.2.  
5.2.2 
Test procedure  
See appended table 5.2.  
 
5.3 
Abnormal operating and fault conditions 
 
 
<11006065 001> 
 
 
Page 24 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
5.3.1 
Protection against overload and abnormal 
operation 
Output overload test, the most 
unfavourable load tested. 
(See appended table 5.3). 
5.3.2 
Motors 
No motors. 
5.3.3 
Transformers 
With the shorted and overload 
o/p of the transformers, no high 
temperature of the transformer 
was recorded. 
Results of the short-circuit tests 
see appended table 5.3 and 
Annex C. 
5.3.4 
Functional insulation ........................................... :  Method c). Results see in 
appended table 5.3. 
5.3.5 
Electromechanical components 
No electromechanical 
component provided. 
5.3.6 
Simulation of faults 
Results see appended table 
5.3. 
5.3.7 
Unattended equipment 
None of the listed components 
was provided. 
5.3.8 
Compliance criteria for abnormal operating and 
fault conditions 
Neither fire burns the equipment 
nor molten metal was emitted. 
Electric strength test primary 
 
SELV, primary 
 plastic 
enclosure were passed. 
 
CONNECTION TO TELECOMMUNICATION NETWORKS 
6.1 
Protection of telecommunication network service persons, and users of other 
equipment connected to the network, from hazards in the equipment 
6.1.1 
Protection from hazardous voltages 
6.1.2 
Separation of the telecommunication network from earth 
6.1.2.1 
Requirements 
 
 
Test voltage (V) ..................................................:   
 
 
Current  in the test circuit  (mA)  .........................:   
 
6.1.2.2 
Exclusions...........................................................:   
 
6.2 
Protection of equipment users from overvoltages on telecommunication networks 
6.2.1 
Separation requirements 
 
6.2.2 
Electric strength test procedure 
 
6.2.2.1 
Impulse test 
 
6.2.2.2 
Steady-state test 
 
6.2.2.3 
Compliance criteria 
 
 
 
<11006065 001> 
 
 
Page 25 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
6.3 
Protection of the telecommunication wiring system from overheating 
 
Max. output current (A) ....................................... :   
 
 
Current limiting method....................................... :   
 
 
CONNECTION TO CABLE DISTRIBUTION SYSTEMS 
7.1 
Protection of cable distribution system service 
persons, and users of other equipment 
connected to the system, from hazardous 
voltages in the equipment 
 
7.2 
Protection of equipment users from overvoltages 
on the cable distribution system 
 
7.3 
Insulation between primary circuits and cable 
distribution systems 
 
7.3.1 
General 
 
7.3.2 
Voltage surge test 
 
7.3.3 
Impulse test 
 
 
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE 
A.1 
Flammability test for fire enclosures of movable equipment having a total mass 
exceeding 18 kg, and of stationary equipment (see 4.7.3.2) 
A.1.1 
Samples .............................................................. :   
 
 
Wall thickness (mm) ........................................... :   
 
A.1.2 
Conditioning of samples; temperature (
°
C)......... :   
A.1.3 
Mounting of samples........................................... :   
A.1.4 
Test flame (see IEC 60695-11-3) 
 
 
Flame A, B, C or D ............................................. :   
 
A.1.5 
Test procedure 
 
A.1.6 
Compliance criteria 
 
 
Sample 1 burning time (s)................................... :   
 
 
Sample 2 burning time (s)................................... :   
 
 
Sample 3 burning time (s)................................... :   
 
A.2 
Flammability test for fire enclosures of movable equipment having a total mass not 
exceeding 18 kg, and for material and components located inside fire enclosures 
(see 4.7.3.2 and 4.7.3.4) 
UL approved material used with flammability class V-1 or better. No further tests 
were considered.
 
A.2.1 
Samples, material ............................................... :   
 
 
Wall thickness (mm) ........................................... :   
 