Harman Kardon GPS 500 EMC - CB Certificate ▷ View online
<11006065 001>
Page 6 of 71
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1
GENERAL
P
1.5
Components
P
1.5.1
General
See below.
P
Comply with IEC 60950 or relevant component
standard
Components which were found
to affect safety aspects comply
with the requirements of this
standard or with the safety
aspects of the relevant IEC/EN
component standards (see
appended table 1.5.1).
P
1.5.2
Evaluation and testing of components
Components that are certified
to IEC and /or national
standards are used correctly
within their ratings.
Components not covered by
IEC standards are tested under
the conditions present in the
equipment.
P
1.5.3
Thermal controls
No thermal controls.
N
1.5.4
Transformers
Transformer used is suitable for
the intended application and
comply with the relevant
requirements of the standard
and particularly with those of
Annex C.
P
1.5.5
Interconnecting cables
Interconnection o/p cable to
other device is carrying only
SELV on an energy level below
240VA.
→
Except for the insulation
material, there are no further
requirements for the o/p
interconnection cable.
P
1.5.6
Capacitors in primary circuits ............................. : Between lines: X2 capacitor
according to IEC 60384-14:1993
with 21 days damp heat test was
used.
P
1.5.7
Double insulation or reinforced insulation bridged
by components
See below.
P
1.5.7.1
General
Ditto.
P
1.5.7.2
Bridging capacitors
Primary and secondary bridged
by one capacitor (C8), which
used was certified as Y1
capacitor according to IEC
60384-14/1993.
P
1.5.7.3
Bridging resistors
No bridging resistors.
N
<11006065 001>
Page 7 of 71
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1.5.7.4
Accessible parts
See clause 2.4.
P
1.5.8
Components in equipment for IT power systems Class II equipment.
N
1.6
Power interface
P
1.6.1
AC power distribution systems
TN power system. IT power
system for Norway.
P
1.6.2
Input current
Highest load according to
1.2.2.1 for this equipment is the
operation with the maximum
specified DC-load.
Results see appended table.
Results see appended table.
P
1.6.3
Voltage limit of hand-held equipment
This appliance is not hand-held
equipment.
N
1.6.4
Neutral conductor
The neutral is not identified in
the equipment. Reinforced
insulation for rated voltage
between secondary parts and
primary phases.
P
1.7
Marking and instructions
P
1.7.1
Power rating
All relevant markings are
provided on a label.
P
Rated voltage(s) or voltage range(s) (V) ............ : 100-240V
∼
P
Symbol for nature of supply, for d.c. only............ : AC source.
N
Rated frequency or rated frequency range (Hz) . : 50-60Hz
P
Rated current (mA or A) ..................................... : 0.2A
P
Manufacturer’s name or trademark or
identification mark .............................................. :
PHIHONG
P
Type/model or type reference ............................. : PSB05R-050, PSB05R-050Q,
PSB05A-050, PSB05C-050,
PSB05E-050, PSB05H-050,
PSB05K-050, PSB05N-050,
PSB05S-050
P
Symbol for Class II equipment only .................... : Double square symbol provided
P
Other symbols .................................................... : Additional symbols or markings
do not give rise to
misunderstanding.
P
Certification marks ............................................. : Not shown
N
<11006065 001>
Page 8 of 71
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1.7.2
Safety instructions
User’s manual provided as
follows:
- maximum operation ambient
- maximum operation ambient
temperature;
- electrical data.
P
1.7.3
Short duty cycles
Equipment is designed for
continuous operation.
N
1.7.4
Supply voltage adjustment ................................. : Full range voltage design, no
necessary adjustment.
N
Methods and means of adjustment; reference to
installation instructions ....................................... :
Ditto.
N
1.7.5
Power outlets on the equipment ........................ : No outlets provided.
N
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) ........................ :
Marking on PCB adjacent to
fuse: RF / F1 2A T 250V
P
1.7.7
Wiring terminals
See below.
N
1.7.7.1
Protective earthing and bonding terminals ......... : Class II equipment.
N
1.7.7.2
Terminal for a.c. mains supply conductors
Direct plug-in equipment.
N
1.7.7.3
Terminals for d.c. mains supply conductors
No d.c. mains supply.
N
1.7.8
Controls and indicators
See below.
N
1.7.8.1
Identification, location and marking .................... : No switch or safety involved
indicator.
N
1.7.8.2
Colours .............................................................. : No indicators.
N
1.7.8.3
Symbols according to IEC 60417........................ : No symbols used.
N
1.7.8.4
Markings using figures ...................................... : No figures used.
N
1.7.9
Isolation of multiple power sources .................... : Only one supply from the
mains.
N
1.7.10
IT power distribution systems
Shall be evaluated when
submitted for Norway national
approval.
N
1.7.11
Thermostats and other regulating devices
No thermostats provided.
N
1.7.12
Language(s) ....................................................... : User manual in German and
English and marking rating in
English. Versions in other
languages will be provided when
national certificate approval.
1.7.13
Durability
The labels were subjected to
the permanence of marking
test. The labels were rubbed
with cloth soaked with water for
15 s and then again for 15 s
with the cloth soaked with
petroleum spirit.
P
<11006065 001>
Page 9 of 71
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
After this test there was no
damage to the labels. The
marking on the labels did not
fade. There was no curling or
lifting of the label's edges.
1.7.14
Removable parts
Marking is not placed on the
replaceable snap-fit plug.
P
1.7.15
Replaceable batteries
No batteries provided.
N
Language(s)........................................................ :
1.7.16
Operator access with a tool ................................ : No operator accessible area
which needs to be accessed by
the use of a tool.
N
1.7.17
Equipment for restricted access locations .......... : Not limited for use in restricted
access locations.
N
2
PROTECTION FROM HAZARDS
P
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
See below.
P
2.1.1.1
Access to energized parts
No access with test finger and
test pin to any parts with only
basic insulation to ELV or
hazardous voltage within the
adapter and replaceable snap-
file connector. Any hazardous
parts accessible are unlikely.
Note: The width of rectangular
Note: The width of rectangular
gap of replaceable snap-fit
connector is 2.8mm.
P
Test by inspection .............................................. : Ditto.
P
Test with test finger ............................................ : Ditto.
P
Test with test pin ................................................ : Ditto.
P
Test with test probe ............................................ : No TNV.
N
2.1.1.2
Battery compartments ........................................ : No battery compartment.
N
2.1.1.3
Access to ELV wiring
No ELV wiring in operator
accessible area.
N
Working voltage (Vpeak or Vrms); minimum
distance (mm) through insulation
2.1.1.4
Access to hazardous voltage circuit wiring
No hazardous voltage wiring in
operator accessible area.
N