<11006065 001> 
 
 
Page 18 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
PHYSICAL REQUIREMENTS 
4.1 
Stability 
Direct plug-in equipment.
 
 
Angle of 10
°
 
 
 
Test: force (N)...................................................... :   
 
4.2 
Mechanical strength 
4.2.1 
General 
See below. After tests, unit 
complies with the requirements 
of sub-clauses 2.1.1 and 2.10. 
4.2.2 
Steady force test, 10 N 
10 N applied to all components 
other than parts serving as an 
enclosure. 
4.2.3 
Steady force test, 30 N 
No internal enclosure. 
4.2.4 
Steady force test, 250 N 
250 N applied to outer 
enclosure. No energy or other 
hazards. The test was 
performed on all sources of 
enclosure material. 
Force applied at: 
side  
top side (with plug) 
bottom side (with label) 
4.2.5 
Impact test 
Direct plug-in equipment. 
 
Fall test 
Ditto. 
 
Swing test 
Ditto. 
4.2.6 
Drop test 
The adaptor has been subjected 
to 3 drops from 1 m height on a 
hard wooden surface. The test 
was performed on all sources of 
enclosure material. 
Impact at: 
side  
top side (with plug) 
bottom side (with label) 
4.2.7 
Stress relief test 
After the test at temperature of 
76.5
°
C, no shrinkage, distortion 
or loosening of any enclosure 
part was noticeable on the 
equipment. The test was 
performed on all sources of 
enclosure material. 
 
 
<11006065 001> 
 
 
Page 19 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
4.2.8 
Cathode ray tubes 
No CRT in the unit. 
 
Picture tube separately certified.......................... :  Ditto. 
4.2.9 
High pressure lamps 
No high pressure lamp 
provided. 
4.2.10 
Wall or ceiling mounted equipment; force (N)  ... :  Not wall or ceiling mounted 
equipment. 
 
4.3 
Design and construction  
4.3.1 
Edges and corners 
Edges and corners of the 
enclosure are rounded. 
4.3.2 
Handles and manual controls; force (N) .............:  No handles or controls provided. 
4.3.3 
Adjustable controls  
Full range voltage design, no 
controls provided. 
4.3.4 
Securing of parts 
Mechanical fixings in such a way 
designed that they will withstand 
mechanical stress occurring in 
normal use. 
4.3.5 
Connection of plugs and sockets 
Mismatching of connectors 
either not possible or does not 
result in any hazard. 
4.3.6 
Direct plug-in equipment 
See below. 
 
 
<11006065 001> 
 
 
Page 20 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
Dimensions (mm) of mains plug for direct 
plug-in    ...............................................................: 
For Australia plug: The 
dimension of the injection part is 
in accordance with the 
requirement of AS/NZS 
3112:2000 incl. Amdt 1 & 2. 
For Argentina plug: The 
dimension of the injection part is 
in accordance with the 
requirement of IRAM 2073:1996 
standard. 
For China plug: The dimension 
of the injection part is in 
accordance with the 
requirement of GB1002-1996 
standard. 
For Europe plug: The dimension 
of the injection part is in 
accordance with the 
requirement of EN 50075:1990 
standard. 
For United Kingdom plug: The 
dimension of the injection part is 
in accordance with the 
applicable requirement of clause 
12 of BS 1363 –1:1995 
For Korea plug: The dimension 
of the injection part is in 
accordance with KSC 8305 
standard. 
For North American and Japan 
plug: The dimension of the 
injection part is in accordance 
with the requirement NEMA  
1-15P non- polarity type. 
 
Torque and pull test of mains plug for direct 
plug-in; torque (Nm); pull (N) ...............................: 
Less than 0.25Nm  
4.3.7 
Heating elements in earthed equipment 
No such elements. 
4.3.8 
Batteries 
No batteries. 
4.3.9 
Oil and grease 
Insulation in intended use not 
considered to be exposed to oil 
or grease. 
4.3.10 
Dust, powders, liquids and gases 
Equipment in intended use not 
considered to be exposed to 
these. 
4.3.11 
Containers for liquids or gases 
No container for liquids or 
gases provided. 
4.3.12 
Flammable liquids ................................................:  No flammable liquids provided. 
 
Quantity of liquid (l) ..............................................:   
 
 
<11006065 001> 
 
 
Page 21 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
Flash point (
°
C) ....................................................:   
4.3.13 
Radiation; type of radiation  .................................:  No ionizing radiation or laser or 
flammable liquids presents.  
4.3.13.1 
General 
 
4.3.13.2 
Ionizing radiation  
 
 
Measured radiation (pA/kg) ................................. :   
 
 
Measured high-voltage (kV) ................................ :   
 
 
Measured focus voltage (kV)  .............................. :   
 
 
CRT markings ..................................................... :   
 
4.3.13.3 
Effect of ultraviolet (UV) radiation on materials 
 
 
Part, property, retention after test, flammability 
classification ........................................................ : 
 
4.3.13.4 
Human exposure to ultraviolet (UV) radiation  ..... :   
4.3.13.5 
Laser (including LEDs) 
 
 
Laser class .......................................................... :   
 
4.3.13.6 
Other types .......................................................... :   
 
4.4 
Protection against hazardous moving parts 
No hazardous moving parts.
 
4.4.1 
General 
 
4.4.2 
Protection in operator access areas 
 
4.4.3 
Protection in restricted access locations  
 
4.4.4 
Protection in service access areas 
 
 
4.5 
Thermal requirements 
4.5.1 
Maximum temperatures 
Refer to appended table 4.5.1 
 
Normal load condition per Annex L...................... :  See 1.6.2. 
4.5.2 
Resistance to abnormal heat 
Refer to appended table 4.5.2 
 
4.6 
Openings in enclosures
 
4.6.1 
Top and side openings 
No openings on the top and 
sides. 
 