Harman Kardon GPS 500 EMC - CB Certificate ▷ View online
<11006065 001>
Page 18 of 71
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
4
PHYSICAL REQUIREMENTS
P
4.1
Stability
Direct plug-in equipment.
N
Angle of 10
°
N
Test: force (N)...................................................... :
N
4.2
Mechanical strength
P
4.2.1
General
See below. After tests, unit
complies with the requirements
of sub-clauses 2.1.1 and 2.10.
P
4.2.2
Steady force test, 10 N
10 N applied to all components
other than parts serving as an
enclosure.
P
4.2.3
Steady force test, 30 N
No internal enclosure.
N
4.2.4
Steady force test, 250 N
250 N applied to outer
enclosure. No energy or other
hazards. The test was
performed on all sources of
enclosure material.
Force applied at:
side
top side (with plug)
bottom side (with label)
Force applied at:
side
top side (with plug)
bottom side (with label)
P
4.2.5
Impact test
Direct plug-in equipment.
N
Fall test
Ditto.
N
Swing test
Ditto.
N
4.2.6
Drop test
The adaptor has been subjected
to 3 drops from 1 m height on a
hard wooden surface. The test
was performed on all sources of
enclosure material.
Impact at:
side
top side (with plug)
bottom side (with label)
Impact at:
side
top side (with plug)
bottom side (with label)
P
4.2.7
Stress relief test
After the test at temperature of
76.5
°
C, no shrinkage, distortion
or loosening of any enclosure
part was noticeable on the
equipment. The test was
performed on all sources of
enclosure material.
P
<11006065 001>
Page 19 of 71
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
4.2.8
Cathode ray tubes
No CRT in the unit.
N
Picture tube separately certified.......................... : Ditto.
N
4.2.9
High pressure lamps
No high pressure lamp
provided.
N
4.2.10
Wall or ceiling mounted equipment; force (N) ... : Not wall or ceiling mounted
equipment.
N
4.3
Design and construction
P
4.3.1
Edges and corners
Edges and corners of the
enclosure are rounded.
P
4.3.2
Handles and manual controls; force (N) .............: No handles or controls provided.
N
4.3.3
Adjustable controls
Full range voltage design, no
controls provided.
N
4.3.4
Securing of parts
Mechanical fixings in such a way
designed that they will withstand
mechanical stress occurring in
normal use.
P
4.3.5
Connection of plugs and sockets
Mismatching of connectors
either not possible or does not
result in any hazard.
P
4.3.6
Direct plug-in equipment
See below.
P
<11006065 001>
Page 20 of 71
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
Dimensions (mm) of mains plug for direct
plug-in ...............................................................:
For Australia plug: The
dimension of the injection part is
in accordance with the
requirement of AS/NZS
3112:2000 incl. Amdt 1 & 2.
For Argentina plug: The
For Argentina plug: The
dimension of the injection part is
in accordance with the
requirement of IRAM 2073:1996
standard.
For China plug: The dimension
For China plug: The dimension
of the injection part is in
accordance with the
requirement of GB1002-1996
standard.
For Europe plug: The dimension
For Europe plug: The dimension
of the injection part is in
accordance with the
requirement of EN 50075:1990
standard.
For United Kingdom plug: The
For United Kingdom plug: The
dimension of the injection part is
in accordance with the
applicable requirement of clause
12 of BS 1363 –1:1995
For Korea plug: The dimension
For Korea plug: The dimension
of the injection part is in
accordance with KSC 8305
standard.
For North American and Japan
For North American and Japan
plug: The dimension of the
injection part is in accordance
with the requirement NEMA
1-15P non- polarity type.
P
Torque and pull test of mains plug for direct
plug-in; torque (Nm); pull (N) ...............................:
Less than 0.25Nm
P
4.3.7
Heating elements in earthed equipment
No such elements.
N
4.3.8
Batteries
No batteries.
N
4.3.9
Oil and grease
Insulation in intended use not
considered to be exposed to oil
or grease.
N
4.3.10
Dust, powders, liquids and gases
Equipment in intended use not
considered to be exposed to
these.
N
4.3.11
Containers for liquids or gases
No container for liquids or
gases provided.
N
4.3.12
Flammable liquids ................................................: No flammable liquids provided.
N
Quantity of liquid (l) ..............................................:
N
<11006065 001>
Page 21 of 71
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
Flash point (
°
C) ....................................................:
N
4.3.13
Radiation; type of radiation .................................: No ionizing radiation or laser or
flammable liquids presents.
N
4.3.13.1
General
N
4.3.13.2
Ionizing radiation
N
Measured radiation (pA/kg) ................................. :
Measured high-voltage (kV) ................................ :
Measured focus voltage (kV) .............................. :
CRT markings ..................................................... :
4.3.13.3
Effect of ultraviolet (UV) radiation on materials
N
Part, property, retention after test, flammability
classification ........................................................ :
N
4.3.13.4
Human exposure to ultraviolet (UV) radiation ..... :
N
4.3.13.5
Laser (including LEDs)
N
Laser class .......................................................... :
4.3.13.6
Other types .......................................................... :
N
4.4
Protection against hazardous moving parts
No hazardous moving parts.
N
4.4.1
General
N
4.4.2
Protection in operator access areas
N
4.4.3
Protection in restricted access locations
N
4.4.4
Protection in service access areas
N
4.5
Thermal requirements
P
4.5.1
Maximum temperatures
Refer to appended table 4.5.1
P
Normal load condition per Annex L...................... : See 1.6.2.
P
4.5.2
Resistance to abnormal heat
Refer to appended table 4.5.2
P
4.6
Openings in enclosures
P
4.6.1
Top and side openings
No openings on the top and
sides.
P
Dimensions (mm) ................................................:
Click on the first or last page to see other GPS 500 service manuals if exist.