Harman Kardon DRIVE AND PLAY 2 (serv.man3) EMC - CB Certificate ▷ View online
Report No. 078214R-RFCEP02V01
Page : 37 of 48
Version:1.0
9.11.
Test Data of Conducted Susceptibility
Product :
drive+play
2
Test Item
:
Conducted Susceptibility
Test Site
:
No.2 EMC fully Chamber
Test Mode
:
Mode 1: Normal Operation
Frequency
Range
(MHz)
Voltage
Applied
dBuV(V)
Inject
Method
Tested Port
of
EUT
Required
Criteria
Performance
Criteria Complied
To
Result
0.15~80 3V CDN DC
IN A
A
PASS
Note:
The testing performed is from lowest level up to the highest level as required by standard, but only highest
level is shown on the report.
level is shown on the report.
Meet criteria A: Operate as intended during and after the test
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional
Information
EUT stopped operation and could / could not be reset by operator at kV of
Line .
No false alarms or other malfunctions were observed during or after the test. The acceptance
criteria were met, and the EUT passed the test.
Report No. 078214R-RFCEP02V01
Page : 38 of 48
Version:1.0
9.12. Test
Photograph
Test Mode : Mode 1: Normal Operation
Description : Conducted Susceptibility Test Setup
Report No. 078214R-RFCEP02V01
Page : 39 of 48
Version:1.0
EUT Photograph
(1) EUT Photo
(2) EUT Photo
Report No. 078214R-RFCEP02V01
Page : 40 of 48
Version:1.0
(3) EUT Photo
(4) EUT Photo
Click on the first or last page to see other DRIVE AND PLAY 2 (serv.man3) service manuals if exist.