Harman Kardon DRIVE AND PLAY 2 (serv.man3) EMC - CB Certificate ▷ View online
Report No. 078214R-RFCEP02V01
Page : 29 of 48
Version:1.0
9.3.
Test Data of Radiated Emission
Product :
drive+play
2
Test Item
:
General Radiated Emission
Test Site
:
No.3 OATS
Test Mode
:
Mode 1: Normal Operation
Frequency Correct Reading
Measurement
Margin Limit
Factor
Level
Level
MHz dB dBuV
dBuV/m
dB
dBuV/m
Horizontal
168.005 12.889 12.860 25.749 -4.251 30.000
196.609 12.668 12.750 25.418 -4.582 30.000
300.034
196.609 12.668 12.750 25.418 -4.582 30.000
300.034
17.402
15.640
33.042
-3.958
37.000
432.004 20.718 2.810 23.529 -13.471 37.000
500.056 22.066 2.130 24.196 -12.804 37.000
624.000 24.044 1.730 25.774 -11.226 37.000
700.000
500.056 22.066 2.130 24.196 -12.804 37.000
624.000 24.044 1.730 25.774 -11.226 37.000
700.000
24.880
3.010
27.890
-9.110
37.000
Vertical
84.010 11.726 14.040 25.766 -4.234 30.000
120.010 15.188 13.120 28.308 -1.692 30.000
144.000
144.000
14.178
14.400
28.578
-1.422
30.000
168.010 12.889 11.760 24.649 -5.351 30.000
221.187 14.237 13.400 27.637 -2.363 30.000
240.000 15.590 14.350 29.940 -7.060 37.000
221.187 14.237 13.400 27.637 -2.363 30.000
240.000 15.590 14.350 29.940 -7.060 37.000
Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average
measurements as necessary.
2. “ ” means the worst emission level.
3. Measurement Level = Reading Level + Correct Factor
3. Measurement Level = Reading Level + Correct Factor
Report No. 078214R-RFCEP02V01
Page : 30 of 48
Version:1.0
9.4. Test
Photograph
Test Mode : Mode 1: Normal Operation
Description : Front View of Radiated Test
Test Mode : Mode 1: Normal Operation
Description : Back View of Radiated Test
Report No. 078214R-RFCEP02V01
Page : 31 of 48
Version:1.0
9.5.
Test Data of Electrostatic Discharge
Product :
drive+play
2
Test Item
:
Electrostatic Discharge
Test Site
:
No.3 Shielded Room
Test Mode
:
Mode 1: Normal Operation
Item
Amount of
Discharge
Voltage
Required
Criteria
Complied To
Criteria (A, B, C)
Results
Air Discharge
10
10
10
+8kV
-8kV
B
B
B
A
A
A
Pass
Pass
Pass
Contact Discharge
25
25
25
+4kV
-4kV
B
B
B
A
A
A
Pass
Pass
Pass
Indirect Discharge
(HCP)
(HCP)
10
10
10
+4kV
-4kV
B
B
B
A
A
A
Pass
Pass
Pass
Indirect Discharge
(VCP Front)
(VCP Front)
10
10
10
+4kV
-4kV
B
B
B
A
A
A
Pass
Pass
Pass
Indirect Discharge
(VCP Left)
(VCP Left)
10
10
10
+4kV
-4kV
B
B
B
A
A
A
Pass
Pass
Pass
Indirect Discharge
(VCP Back)
(VCP Back)
10
10
10
+4kV
-4kV
B
B
B
A
A
A
Pass
Pass
Pass
Indirect Discharge
(VCP Right)
(VCP Right)
10
10
10
+4kV
-4kV
B
B
B
A
A
A
Pass
Pass
Pass
Note:
The testing performed is from lowest level up to the highest level as required by standard, but only highest
level is shown on the report.
level is shown on the report.
NR: No Requirement
Meet criteria A: Operate as intended during and after the test
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional
Information
EUT stopped operation and could / could not be reset by operator at kV.
No false alarms or other malfunctions were observed during or after the test.
No false alarms or other malfunctions were observed during or after the test.
Report No. 078214R-RFCEP02V01
Page : 32 of 48
Version:1.0
9.6. Test
Photograph
Test Mode :Mode 1: Normal Operation
Description : ESD Test Setup