Harman Kardon DRIVE AND PLAY 2 (serv.man3) EMC - CB Certificate ▷ View online
Report No. 078214R-RFCEP02V01
Page : 17 of 48
Version:1.0
4.4. Test
Procedure
Direct application of discharges to the EUT:
Contact discharge was applied only to conductive surfaces of the EUT.
Air discharges were applied only to non-conductive surfaces of the EUT.
During the test, it was performed with single discharges. For the single discharge time
between successive single discharges will be keep longer 1 second. It was at least ten single
discharges with positive and negative at the same selected point.
The selected point, which was performed with electrostatic discharge, was marked on the
red label of the EUT.
Air discharges were applied only to non-conductive surfaces of the EUT.
During the test, it was performed with single discharges. For the single discharge time
between successive single discharges will be keep longer 1 second. It was at least ten single
discharges with positive and negative at the same selected point.
The selected point, which was performed with electrostatic discharge, was marked on the
red label of the EUT.
Indirect application of discharges to the EUT:
Vertical Coupling Plane (VCP):
The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and positioned at a
distance 0.1m from, the EUT, with the Discharge Electrode touching the coupling plane.
The four faces of the EUT will be performed with electrostatic discharge. It was at least ten
single discharges with positive and negative at the same selected point.
Horizontal Coupling Plane (HCP):
The coupling plane is placed under to the EUT. The generator shall be positioned vertically
at a distance of 0.1m from the EUT, with the Discharge Electrode touching the coupling
plane.
The four faces of the EUT will be performed with electrostatic discharge. It was at least ten
single discharges with positive and negative at the same selected point.
The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and positioned at a
distance 0.1m from, the EUT, with the Discharge Electrode touching the coupling plane.
The four faces of the EUT will be performed with electrostatic discharge. It was at least ten
single discharges with positive and negative at the same selected point.
Horizontal Coupling Plane (HCP):
The coupling plane is placed under to the EUT. The generator shall be positioned vertically
at a distance of 0.1m from the EUT, with the Discharge Electrode touching the coupling
plane.
The four faces of the EUT will be performed with electrostatic discharge. It was at least ten
single discharges with positive and negative at the same selected point.
4.5. Test
Specification
According to EN 61000-4-2:1995+A1: 1998+A2: 2001
4.6. Uncertainty
±
6.003 %
4.7. Test
Result
The measurement of the electrostatic discharge was investigated and test result was shown in
section 12. The acceptance criterion was met and the EUT passed the test.
section 12. The acceptance criterion was met and the EUT passed the test.
Report No. 078214R-RFCEP02V01
Page : 18 of 48
Version:1.0
5.
Radiated Susceptibility (RS)
5.1. Test
Equipment
Item Equipment
Manufacturer
Model No. / Serial No.
Last Cal.
1
Signal Generator
R & S
SMY02 / 825454/029
Oct., 2006
2
Power Amplifier
A & R
100W10000M7 /
A285000010
A285000010
N/A
3
RF Power Amplifier
OPHIRRF
5022F / 1075
N/A
4
Bilog Antenna
Chase
CBL6112B / 2452
Sep., 2007
5
Power Meter
R & S
NRVD / 100219
Jan., 2007
6
Directional Coupler
A & R
DC6180 / 22735
Jan, 2007
7
No.2 EMC Fully Chamber
N/A
Note: All equipments are calibrated every one year.
5.2. Test
Setup
Report No. 078214R-RFCEP02V01
Page : 19 of 48
Version:1.0
5.3. Test
Level
Item Environmental
Phenomena
Units
Test Specification Performance Criteria
Enclosure Port
Radio-Frequency
Electromagnetic Field
Amplitude Modulated
MHz
V/m(Un-modulated, rms)
% AM (1kHz)
80-1000
1400-2000
3
80
A
5.4. Test
Procedure
The EUT and load, which are placed on a table that is 0.8 meter above ground, are placed with
one coincident with the calibration plane such that the distance from antenna to the EUT was 3
meters.
Both horizontal and vertical polarization of the antenna and four sides of the EUT are set on
measurement.
In order to judge the EUT performance, a CCD camera is used to monitor EUT screen, and a
plastic tube to monitor the sound output.
one coincident with the calibration plane such that the distance from antenna to the EUT was 3
meters.
Both horizontal and vertical polarization of the antenna and four sides of the EUT are set on
measurement.
In order to judge the EUT performance, a CCD camera is used to monitor EUT screen, and a
plastic tube to monitor the sound output.
All the scanning conditions are as follows:
Condition
of
Test
Remarks
1. Field Strength
6 V/m Level 2
2. Radiated Signal
AM 80% Modulated with 1kHz sinusoidal audio signal
3. Scanning
Frequency
80MHz - 1000MHz, 1400MHz - 3000MHz
4 Dwell
Time
3 Seconds
5. Frequency step size
∆ f
: 1%
6. The rate of Swept of Frequency
1.5 x 10
-3
decades/s
5.5. Test
Specification
According to EN 61000-4-3:2002+A1: 2002
5.6. Uncertainty
±
6.17 %
5.7. Test
Result
The measurement of the radiated susceptibility was investigated and test result was shown in
section 12. The acceptance criterion was met and the EUT passed the test.
section 12. The acceptance criterion was met and the EUT passed the test.
Report No. 078214R-RFCEP02V01
Page : 20 of 48
Version:1.0
6. Surge
6.1. Test
Equipment
Item Instrument
Manufacturer
Type No/Serial No.
Last Calibration
1
Surge Generator SCHAFFNER
NSG 2050
S/N: 200124-031AR
S/N: 200124-031AR
Nov., 2006
2
No.3 Shielded Room
N/A
Note: All equipments are calibrated every one year.
6.2. Test
Setup
6.3. Test
Level
Item Environmental
Phenomena
Units
Test Specification Performance Criteria
Telecommunication Ports (See
1)
and
2)
)
Surges
Line to Ground
Tr/Th us
kV
1.2/50 (8/20)
± 1
B
Telecommunication Ports in Telecom Centres (See
1)
and
2)
)
Surges
Line to Ground
Tr/Th us
kV
1.2/50 (8/20)
± 0.5
B
AC Input and AC Output Power Ports
Surges
Line to Line
Line to Ground
Tr/Th us
kV
kV
kV
1.2/50 (8/20)
±1
± 2
B
AC Input and AC Output Power Ports in Telecom Centres
Surges
Line to Line
Line to Ground
Tr/Th us
kV
kV
kV
1.2/50 (8/20)
±0.5
± 1
B
Notes:
Applicable only to ports which according to the manufacturer’s may directly to outdoor cables.
Where normal functioning cannot be achieved because of the impact of the CDN on the EUT, no immunity test
shall be required.
Surge
Generator
EUT
Load
PC
Non-Conducted Table
Non-Conducted Table