Harman Kardon DRIVE AND PLAY 2 (serv.man3) EMC - CB Certificate ▷ View online
Report No. 078214R-RFCEP02V01
Page : 33 of 48
Version:1.0
9.7.
Test Data of Radiated Susceptibility
Product :
drive+play
2
Test Item
:
Radiated Susceptibility
Test Site
:
No.2 EMC fully Chamber
Test Mode
:
Mode 1: Normal Operation
Frequency
(MHz)
Position
(Angle)
Polarity
(H or V)
Field
Strength
(V/m)
Required
Criteria
Complied To
Criteria
(A, B, C)
Results
80-1000 Front
H 6
A
A
Pass
80-1000 Front
V 6
A
A
Pass
80-1000 Back
H 6
A
A
Pass
80-1000 Back
V 6
A
A
Pass
80-1000 Left
H 6 A
A Pass
80-1000 Left
V 6 A
A Pass
80-1000 Right
H 6
A
A
Pass
80-1000 Right
V 6
A
A
Pass
80-1000 Top
H 6 A
A Pass
80-1000 Top
V 6 A
A Pass
80-1000 Down
H 6
A
A
Pass
80-1000 Down
V 6
A
A
Pass
1400-2000 Front H
6
A
A
Pass
1400-2000 Front V
6
A
A
Pass
1400-2000 Back H
6
A
A
Pass
1400-2000 Back V
6
A
A
Pass
1400-2000 Left H 6
A
A
Pass
1400-2000 Left V 6
A
A
Pass
1400-2000 Right H
6
A
A
Pass
1400-2000 Right V
6
A
A
Pass
1400-2000 Top H 6
A
A
Pass
1400-2000 Top V 6
A
A
Pass
1400-2000 Down H
6
A
A
Pass
1400-2000 Down V
6
A
A
Pass
Note:
The testing performed is from lowest level up to the highest level as required by standard, but only highest
level is shown on the report.
level is shown on the report.
Meet criteria A: Operate as intended during and after the test
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional Information
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional Information
There was no observable degradation in performance.
EUT stopped operation and could / could not be reset by operator at V/m
EUT stopped operation and could / could not be reset by operator at V/m
at frequency MHz.
No false alarms or other malfunctions were observed during or after the test.
Report No. 078214R-RFCEP02V01
Page : 34 of 48
Version:1.0
9.8. Test
Photograph
Test Mode :Mode 1: Normal Operation
Description : Radiated Susceptibility Test Setup
Report No. 078214R-RFCEP02V01
Page : 35 of 48
Version:1.0
9.9.
Test Data of Surge
Product :
drive+play
2
Test Item
:
Surge
Test Site
:
No. 3 Shielded Room
Test Mode
:
Mode 1: Normal Operation
Inject
Line
Polarity Angle
Voltage
(kV)
Time
Interval
(Second)
Inject
Method
Required
Criteria
Complied to
Criteria
Result
L-N
±
0 1kV 60 Direct B
A PASS
L-N
±
90 1kV 60 Direct B
A PASS
L-N
±
180 1kV
60 Direct
B
A PASS
L-N
±
270 1kV
60 Direct
B
A PASS
Note:
The testing performed is from lowest level up to the highest level as required by standard, but only highest
level is shown on the report.
level is shown on the report.
Meet criteria A : Operate as intended during and after the test
Meet criteria B : Operate as intended after the test
Meet criteria C : Loss/Error of function
Additional Information
Meet criteria B : Operate as intended after the test
Meet criteria C : Loss/Error of function
Additional Information
EUT stopped operation and could / could not be reset by operator at kV of
Line .
No false alarms or other malfunctions were observed during or after the test.
Report No. 078214R-RFCEP02V01
Page : 36 of 48
Version:1.0
9.10. Test
Photograph
Test Mode Mode 1: Normal Operation
Description : SURGE Test Setup
Click on the first or last page to see other DRIVE AND PLAY 2 (serv.man3) service manuals if exist.