DOWNLOAD Harman Kardon DRIVE AND PLAY 2 (serv.man3) Service Manual ↓ Size: 2.03 MB | Pages: 48 in PDF or view online for FREE

Model
DRIVE AND PLAY 2 (serv.man3)
Pages
48
Size
2.03 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Car Audio
File
drive-and-play-2-sm3.pdf
Date

Harman Kardon DRIVE AND PLAY 2 (serv.man3) EMC - CB Certificate ▷ View online

 
 
Report No. 078214R-RFCEP02V01
 
 
 
 
Page : 13 of 48 
 
Version:1.0 
 
 
2.4. Test 
Procedure 
AC Mains: 
The EUT and simulators are connected to the main power through a line impedance stabilization 
network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for the measuring equipment. 
The peripheral devices are also connected to the main power through a LISN that provides a 50ohm 
/50uH coupling impedance with 50ohm termination. (Please refers to the block diagram of the test 
setup and photographs.) 
Both sides of AC line are checked for maximum conducted interference. In order to find the maximum 
emission, the relative positions of equipment and all of the interface cables must be changed according 
to ETSI EN 301 489-1:V1.6.1 (2005-09) on conducted measurement. 
The bandwidth of the field strength meter (R & S Test Receiver ESCS 30) is set at 9kHz. 
Telecommunication Port: 
The mains voltage shall be supplied to the EUT via the LISN when the measurement of 
telecommunication port is performed. The common mode disturbances at the telecommunication port 
shall be connected to the ISN, which is 150ohm impedance. Both alternative cables are tested related to 
the LCL requested. The measurement range is from 150kHz to 30MHz. The bandwidth of measurement 
is set to 9kHz. The 60dB LCL ISN is used for cat. 5 cable, 50dB LCL ISN is used for cat. 3 and 80dB 
LCL is wed for alternative one. 
2.5. Test 
Specification 
According to ETSI EN 301 489-1:V1.6.1 (2005-09) 
           EN 55022:1998+A1: 2000+A2: 2003 
2.6. Uncertainty 
±
 2.26 dB 
2.7. Test 
Result 
The emission from the EUT was below the specified limits. The worst-case emissions are shown in 
section 12. The acceptance criterion was met and the EUT passed the test. 
 
 
Report No. 078214R-RFCEP02V01
 
 
 
 
Page : 14 of 48 
 
Version:1.0 
 
 
3. 
Radiated Emission
 
3.1. Test 
Equipment 
The following test equipment are used during the Radiated emission test: 
Test Site 
Equipment 
Manufacturer
Model No./Serial No. 
Last Cal. 
Test Receiver 
R & S 
ESVS 10 / 834468/003 
July, 2007 
Spectrum Analyzer  Advantest 
R3162/ 00803480 
May, 2007 
Pre-Amplifier 
Advantest 
BB525C/ 3307A01812 
May, 2007 
Site # 1 
 
Bilog Antenna 
SCHAFFNER 
CBL6112B / 2697 
Nov., 2006 
Test Receiver 
R & S 
ESCS 30 / 836858 / 022 
Nov., 2006 
Spectrum Analyzer  Advantest 
R3162 / 100803466 
May, 2007 
Pre-Amplifier Advantest BB525C/3307A01814  May, 
2007 
Bilog Antenna 
SCHAFFNER 
CBL6112B / 2705 
Oct., 2006 
Horn Antenna 
ETS 
3115 / 0005-6160 
July, 2007 
Site # 2 
Pre-Amplifier 
QTK 
QTK-AMP-01/ 0001 
July, 2007 
Test Receiver 
R & S 
ESI 26 / 838786 / 004 
May, 2007 
Spectrum Analyzer  Advantest 
R3162 / 100803480 
May, 2007 
Pre-Amplifier 
QTK 
QTK-AMP-03 / 0003 
May, 2007 
Bilog Antenna 
SCHAFFNER 
CBL6112B / 2697 
May, 2007 
Horn Antenna 
ETS 
3115 / 0005-6160 
July, 2007 
Site # 3 
Pre-Amplifier 
QTK 
QTK-AMP-01 / 0001 
July, 2007 
Note: 
1. All equipments are calibrated every one year. 
 
2. The test instruments marked by “X” are used to measure the final test results. 
3.2. Test 
Setup 
 
 
                   
 
 
 
 
 
 
 
 
 
 
 
 
 
EUT
FRP Dome
 
Test 
Receiver 
Antenna Mast 
Dipole or Horn Antenna 
Antenna height can be 
moved from 1m to 4m, 
Antenna and turntable 
distance 3m
   
TO Controller
To Receiver
Fully Soldered Ground Plane 
Non-Conducted 
Table 
10m
1m to 4m
80cm
Load 
 
 
Report No. 078214R-RFCEP02V01
 
 
 
 
Page : 15 of 48 
 
Version:1.0 
 
 
3.3. Limits 
Limits (dBuV/m) 
Limit for radiated emissions from 
ancillary equipment intended for 
use in telecommunication centers 
only, and measured on a stand 
alone basis 
Limit for radiated emissions from 
ancillary equipment, measured on 
a stand alone basis 
Frequency 
MHz 
QP QP 
30-230 
40 
30 
230-1000 47 
37 
3.4. Test 
Procedure 
The EUT and its simulators are placed on a turn table which is 0.8 meter above ground. The turn table 
can rotate 360 degrees to determine the position of the maximum emission level. The EUT was 
positioned such that the distance from antenna to the EUT was 10 meters.The antenna can move up 
and down between 1 meter and 4 meters to find out the maximum emission level.   
Both horizontal and vertical polarization of the antenna are set on measurement. In order to find the 
maximum emission, all of the interface cables must be manipulated according to 
ETSI EN 301 
489-1:V1.6.1 (2005-09)
 on radiated measurement. 
The additional motch filter below 1GHz was used to measure the level of harmonics radiated emission 
during field dtrength of harmonics measurement. The bandwidth below 1GHz setting on the field 
strength meter (R&S Test Receiver ESCS 30 )is 120 kHz, and 1MHz bandwidth is adpted above 1GHz. 
The frequency range from 30MHz to 10
th
 harmonics is checked. 
3.5. Test 
Specification 
According to ETSI EN 301 489-1:V1.6.1 (2005-09) 
           EN 55022:1998+A1: 2000+A2: 2003 
3.6. Uncertainty 
±
 3.8 dB 
3.7. Test 
Result 
The emission from the EUT was below the specified limits. The worst-case emissions are shown in 
section 12. The acceptance criterion was met and the EUT passed the test. 
 
 
 
Report No. 078214R-RFCEP02V01
 
 
 
 
Page : 16 of 48 
 
Version:1.0 
 
 
4. 
Electrostatic Discharge (ESD) 
4.1. Test 
Equipment 
 
Item  Instrument   
Manufacturer 
Type No/Serial No. 
Last Calibration 
1  ESD Simulator System  SCHAFFNER 
NSG-438 S/N: 167 
June, 2007 
2  Horizontal Coupling 
Plane (HCP)
QuieTek HCP 
AL50 
N/A 
3  Vertical Coupling Plane 
(VCP) 
QuieTek VCP 
AL50
 
N/A 
4  No.3 Shielded Room 
N/A 
Note: All equipments are calibrated every one year. 
4.2. Test 
Setup 
 
 
 
 
 
 
 
 
 
 
 
 
 
4.3. Test 
Level 
Item Environmental 
Phenomena 
Units 
Test Specification  Performance Criteria
Enclosure Port 
 Electrostatic 
Discharge kV(Charge 
Voltage) 
±8 Air Discharge 
±4 Contact Discharge 
 
 
Metal Ground Plane 
ESD 
Simulator
EUT 
Loads: 
Active
 
Insulation
 
Horizontal Coupling Plane 
Non-Conducted table 
470K ohm 
Resistor
 
470K ohm Resistor 
Vertical Coupling Plane 
80cm
 
Page of 48