Harman Kardon DRIVE AND PLAY 2 (serv.man3) EMC - CB Certificate ▷ View online
Report No. 078214R-RFCEP02V01
Page : 13 of 48
Version:1.0
2.4. Test
Procedure
AC Mains:
The EUT and simulators are connected to the main power through a line impedance stabilization
network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for the measuring equipment.
The peripheral devices are also connected to the main power through a LISN that provides a 50ohm
/50uH coupling impedance with 50ohm termination. (Please refers to the block diagram of the test
setup and photographs.)
The peripheral devices are also connected to the main power through a LISN that provides a 50ohm
/50uH coupling impedance with 50ohm termination. (Please refers to the block diagram of the test
setup and photographs.)
Both sides of AC line are checked for maximum conducted interference. In order to find the maximum
emission, the relative positions of equipment and all of the interface cables must be changed according
to ETSI EN 301 489-1:V1.6.1 (2005-09) on conducted measurement.
The bandwidth of the field strength meter (R & S Test Receiver ESCS 30) is set at 9kHz.
emission, the relative positions of equipment and all of the interface cables must be changed according
to ETSI EN 301 489-1:V1.6.1 (2005-09) on conducted measurement.
The bandwidth of the field strength meter (R & S Test Receiver ESCS 30) is set at 9kHz.
Telecommunication Port:
The mains voltage shall be supplied to the EUT via the LISN when the measurement of
telecommunication port is performed. The common mode disturbances at the telecommunication port
shall be connected to the ISN, which is 150ohm impedance. Both alternative cables are tested related to
the LCL requested. The measurement range is from 150kHz to 30MHz. The bandwidth of measurement
is set to 9kHz. The 60dB LCL ISN is used for cat. 5 cable, 50dB LCL ISN is used for cat. 3 and 80dB
LCL is wed for alternative one.
shall be connected to the ISN, which is 150ohm impedance. Both alternative cables are tested related to
the LCL requested. The measurement range is from 150kHz to 30MHz. The bandwidth of measurement
is set to 9kHz. The 60dB LCL ISN is used for cat. 5 cable, 50dB LCL ISN is used for cat. 3 and 80dB
LCL is wed for alternative one.
2.5. Test
Specification
According to ETSI EN 301 489-1:V1.6.1 (2005-09)
EN 55022:1998+A1: 2000+A2: 2003
EN 55022:1998+A1: 2000+A2: 2003
2.6. Uncertainty
±
2.26 dB
2.7. Test
Result
The emission from the EUT was below the specified limits. The worst-case emissions are shown in
section 12. The acceptance criterion was met and the EUT passed the test.
section 12. The acceptance criterion was met and the EUT passed the test.
Report No. 078214R-RFCEP02V01
Page : 14 of 48
Version:1.0
3.
Radiated Emission
3.1. Test
Equipment
The following test equipment are used during the Radiated emission test:
Test Site
Equipment
Manufacturer
Model No./Serial No.
Last Cal.
Test Receiver
R & S
ESVS 10 / 834468/003
July, 2007
Spectrum Analyzer Advantest
R3162/ 00803480
May, 2007
Pre-Amplifier
Advantest
BB525C/ 3307A01812
May, 2007
Site # 1
Bilog Antenna
SCHAFFNER
CBL6112B / 2697
Nov., 2006
Test Receiver
R & S
ESCS 30 / 836858 / 022
Nov., 2006
Spectrum Analyzer Advantest
R3162 / 100803466
May, 2007
Pre-Amplifier Advantest BB525C/3307A01814 May,
2007
Bilog Antenna
SCHAFFNER
CBL6112B / 2705
Oct., 2006
Horn Antenna
ETS
3115 / 0005-6160
July, 2007
Site # 2
Pre-Amplifier
QTK
QTK-AMP-01/ 0001
July, 2007
Test Receiver
R & S
ESI 26 / 838786 / 004
May, 2007
Spectrum Analyzer Advantest
R3162 / 100803480
May, 2007
Pre-Amplifier
QTK
QTK-AMP-03 / 0003
May, 2007
Bilog Antenna
SCHAFFNER
CBL6112B / 2697
May, 2007
Horn Antenna
ETS
3115 / 0005-6160
July, 2007
Site # 3
Pre-Amplifier
QTK
QTK-AMP-01 / 0001
July, 2007
Note:
1. All equipments are calibrated every one year.
2. The test instruments marked by “X” are used to measure the final test results.
3.2. Test
Setup
EUT
FRP Dome
Test
Receiver
Antenna Mast
Dipole or Horn Antenna
Antenna height can be
moved from 1m to 4m,
Antenna and turntable
distance 3m
Dipole or Horn Antenna
Antenna height can be
moved from 1m to 4m,
Antenna and turntable
distance 3m
TO Controller
To Receiver
Fully Soldered Ground Plane
Non-Conducted
Table
Table
10m
1m to 4m
80cm
Load
Report No. 078214R-RFCEP02V01
Page : 15 of 48
Version:1.0
3.3. Limits
Limits (dBuV/m)
Limit for radiated emissions from
ancillary equipment intended for
use in telecommunication centers
only, and measured on a stand
alone basis
Limit for radiated emissions from
ancillary equipment, measured on
a stand alone basis
Frequency
MHz
QP QP
30-230
40
30
230-1000 47
37
3.4. Test
Procedure
The EUT and its simulators are placed on a turn table which is 0.8 meter above ground. The turn table
can rotate 360 degrees to determine the position of the maximum emission level. The EUT was
positioned such that the distance from antenna to the EUT was 10 meters.The antenna can move up
and down between 1 meter and 4 meters to find out the maximum emission level.
Both horizontal and vertical polarization of the antenna are set on measurement. In order to find the
maximum emission, all of the interface cables must be manipulated according to
can rotate 360 degrees to determine the position of the maximum emission level. The EUT was
positioned such that the distance from antenna to the EUT was 10 meters.The antenna can move up
and down between 1 meter and 4 meters to find out the maximum emission level.
Both horizontal and vertical polarization of the antenna are set on measurement. In order to find the
maximum emission, all of the interface cables must be manipulated according to
ETSI EN 301
489-1:V1.6.1 (2005-09)
on radiated measurement.
The additional motch filter below 1GHz was used to measure the level of harmonics radiated emission
during field dtrength of harmonics measurement. The bandwidth below 1GHz setting on the field
strength meter (R&S Test Receiver ESCS 30 )is 120 kHz, and 1MHz bandwidth is adpted above 1GHz.
The frequency range from 30MHz to 10
during field dtrength of harmonics measurement. The bandwidth below 1GHz setting on the field
strength meter (R&S Test Receiver ESCS 30 )is 120 kHz, and 1MHz bandwidth is adpted above 1GHz.
The frequency range from 30MHz to 10
th
harmonics is checked.
3.5. Test
Specification
According to ETSI EN 301 489-1:V1.6.1 (2005-09)
EN 55022:1998+A1: 2000+A2: 2003
EN 55022:1998+A1: 2000+A2: 2003
3.6. Uncertainty
±
3.8 dB
3.7. Test
Result
The emission from the EUT was below the specified limits. The worst-case emissions are shown in
section 12. The acceptance criterion was met and the EUT passed the test.
section 12. The acceptance criterion was met and the EUT passed the test.
Report No. 078214R-RFCEP02V01
Page : 16 of 48
Version:1.0
4.
Electrostatic Discharge (ESD)
4.1. Test
Equipment
Item Instrument
Manufacturer
Type No/Serial No.
Last Calibration
1 ESD Simulator System SCHAFFNER
NSG-438 S/N: 167
June, 2007
2 Horizontal Coupling
Plane (HCP)
QuieTek HCP
AL50
N/A
3 Vertical Coupling Plane
(VCP)
QuieTek VCP
AL50
N/A
4 No.3 Shielded Room
N/A
Note: All equipments are calibrated every one year.
4.2. Test
Setup
4.3. Test
Level
Item Environmental
Phenomena
Units
Test Specification Performance Criteria
Enclosure Port
Electrostatic
Discharge kV(Charge
Voltage)
±8 Air Discharge
±4 Contact Discharge
B
Metal Ground Plane
ESD
Simulator
EUT
Loads:
Active
Insulation
Horizontal Coupling Plane
Non-Conducted table
470K ohm
Resistor
Resistor
470K ohm Resistor
Vertical Coupling Plane
80cm