Harman Kardon TU 980 EMC - CB Certificate ▷ View online
- Page 6 of 38 -
Report
No.
97673
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ................................. :
Class II apparatus
P
4
GENERAL CONDITIONS OF TESTS
4.1.4 Ventilation
instructions
require the use of the test
box
No.
Tested in a wooden test
box according to standard
requirements.
Tested in a wooden test
box according to standard
requirements.
N/A
5 MARKING
Comprehensible and easily discernible
On front and rear side of the
enclosure
enclosure
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / spirit
P
5.1 Identification,
maker, model ................................... :
Maker:
“Harman / Kardon”
Model: “TU980”
See copy of marking plate.
See copy of marking plate.
P
Class II symbol if applicable
Class II symbol is applied
in according to IEC 60417-
5172.
in according to IEC 60417-
5172.
P
Rated supply voltage and symbol .......................... :
“220V-230V” or “220V”
and AC-symbol (
~
) used.
P
Frequency if safety dependant
“50/60 Hz” or “60Hz”
P
Rated current or power consumption .................... :
11W
P
5.2 Earth
terminal
Class II apparatus.
N/A
Hazardous live terminals
No hazardous live terminals
P
Supply output terminals (other than mains)
No socket outlet for providing
power to other apparatus.
power to other apparatus.
N/A
5.3
Use of triangle with exclamation mark
Correct symbol applied;
printed on rear side in
connection with CAUTION
of opening. Further,
no incorrect use of this
symbol found.
printed on rear side in
connection with CAUTION
of opening. Further,
no incorrect use of this
symbol found.
P
5.4
Instructions for use
User information in the
following language: English.
See comments in Summary
of Testing.
following language: English.
See comments in Summary
of Testing.
P
- Page 7 of 38 -
Report
No.
97673
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled with
liquid, etc.
or splashing. Warning concerning objects filled with
liquid, etc.
The user manual includes
information about danger
concerning dripping or
splashing and objects filled
with liquids.
information about danger
concerning dripping or
splashing and objects filled
with liquids.
P
Hazardous live terminals, instructions for wiring
No hazardous live terminals
N/A
Instructions for replacing lithium battery
Not used lithium battery.
N/A
Instructions for modem if fitted
No modem
N/A
Class I earth connection warning
Class II apparatus
N/A
Instructions for multimedia system connection
Not applicable
N/A
Special stability warning for fixed installation
Not for fixed installation
N/A
Warning: battery exposure to heat
Not used lithium battery.
N/A
Warning: protective film on CRT face
No CRT
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Plug is regarded as
disconnect device and is
readily operable.
disconnect device and is
readily operable.
P
Instructions for permanently connected equipment
Not permanently connected
equipment
equipment
N/A
- Page 8 of 38 -
Report
No.
97673
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
6 HAZARDOUS
RADIATION
N/A
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionising radiation.
N/A
6.1
EN 60065
European Council Directive 96/29/Euratom of 13 May
1996 10cm from outer surface of apparatus <1µSv/h
(0,1mR/h)
1996 10cm from outer surface of apparatus <1µSv/h
(0,1mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... :
No laser radiation.
N/A
Emission limits under fault conditions .................... :
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values, no
operation of fuse links
operation of fuse links
No fuse links operate during
normal operating operation.
See appended table
normal operating operation.
See appended table
P
7.1.1
Temperature rise of accessible parts
See appended table
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
See appended table
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
See appended table
P
7.1.4
Temperature rise of windings
See appended table
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
See appended table
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
°
C
< 0,2 A
N/A
- Page 9 of 38 -
Report
No.
97673
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Operation “By hand”
not possible
not possible
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic materials
N/A
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No cover removable by
hand
hand
N/A
8.5
Class I equipment
Class II equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Class II apparatus.
P
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Double/Reinforced
insulation complies with
requirements specified in
clause 10 and 13.
insulation complies with
requirements specified in
clause 10 and 13.
P
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
The apparatus has
isolating transformer.
isolating transformer.
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
No such capacitors.
N/A
Reinforced or double insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
No such capacitors.
N/A
Reinforced or double insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
No such capacitors.
N/A
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
No such components.
N/A
Click on the first or last page to see other TU 980 service manuals if exist.