- Page 30 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
 
IEC 62151 clause 4.1.1: 
Add after the first paragraph: 
 
NOTE- In Finland, Norway and Sweden, class I 
equipment which is intended for connection to the 
building installation via a non-industrial plug or a non-
industrial appliance coupler, or both and in addition is 
intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
ACCESSIBLE parts, have a marking stating that the 
equipment must be connected to an earthed mains 
socket-outlet. 
 
The marking text in the applicable countries shall be 
as follow: 
 
In Finland,  
"Laite on liitettävä suojamaadoituskoskettimilla va 
rustettuunpistorasiaan” 
 
In Norway, 
"Apparatet må tilkoples jordet stikkontakt" 
 
In Sweden, 
"Apparaten skall anslutas till jordat uttag” 
Class II apparatus 
N/A 
 
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH 
APPARATUS FOR PHOTOGRAPHIC PURPOSES. 
N/A 
L5.4 
Marking and Instructions 
No electronic flash  
apparatus 
N/A 
L9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE 
 N/A 
L7.1.5 & 
L11.2.6 
Lithium batteries meet permissible temp rise in Table  
3 , unless comply with 6.3.2 of IEC 60086-4 
 N/A 
L14.6.6 
Mains switch characteristics   appropriate to its 
function under normal conditions 
 N/A 
 
 
- Page 31 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
No mains switch 
 
 
Position of the functional switch (W) : 
F
unctional switch off (standby) mode:
 
4,59W 
— 
 
Operating conditions 
Standby mode at 50Hz;
 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
220 
0,025 4,28  — 
230 
0,026 4,50  — 
Standby mode at 60Hz;
 
220 
0,026 4,19  — 
230 
0,027 4,59  — 
 
 
 
 
 
Functional switch “ON” with “DAB” (or FM)* signal tuned mode at 50Hz;
 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
198 
0,051 8,7  — 
220 
0,055 10,2  — 
230 
0,057 11,0  — 
253 
0,060 12,7  — 
 
 
 
 
Functional switch “ON” with “DAB” (or FM)* signal tuned mode at 60Hz;
 
198 
0,051 8,6  — 
220 
0,055 10,1  — 
230 
0,057 10,8  — 
242 
0,057 11,7  — 
253 
0,058 12,5  — 
 
 
 
 
*) Measured input data in “FM” mode is not different with “DAB” mode.
 
 
 
 
- Page 32 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
Monitored point: 
dT (K) at 
253V, 50Hz
dT (K) at  
198V, 50Hz
dT (K) at 
253V, 60Hz
dT (K) at   
198V, 60Hz 
Limit dT (K) *
Main transformer core 
19,9  
14,2  
20,9  
14,7  
85 
IC204 heat-sink 
24,8  
22,4  
26,7  
23,1  
PWB near D912 
29,2  
24,7  
30,8  
25,3  
70 
E-capacitor, C930 body 
25,2  
17,6  
26,8  
18,1  
50 
IC91 heat-sink 
47,5  
25,2  
49,1  
25,6  
PWB near IC91 
43,5  
23,4  
45,3  
23,9  
70 
Power cord bushing 
9,1  
7,1  
10,7  
7,6  
60 
Top enclosure above transformer 
10,5  
8,0  
12,1  
8,1  
40 
Top enclosure above IC91  
14,6  
9,4  
16,1  
9,6  
40 
Standby button (Non-metallic) 
0,6  
0,5  
1,7  
0,8  
50 
 
 
 
 
 
 
*)   Temperature rise limits for Singapore is 10K less 
 
         
 
Winding temperature rise 
measurements 
253V, 
50Hz 
198V,  
50Hz 
253V, 
60Hz 
198V, 
60Hz 
— 
         
 
Ambient temperature t1 (
o
C) : 
24,4 24,4 24,4 24,4 
— 
         
 
Ambient temperature t2 (
o
C) : 
27,3 26,3 24,7 23,2 
— 
Temperature rise dT of winding: 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit dT (K) 
*) 
Insulation 
class 
Main transf. Primary winding (253V, 50Hz)
130,2 143,8  24,1  85 
Main transf. Primary winding (198V, 50Hz)
130,2 140,2  18,0  85 
Main transf. Primary winding (253V, 60Hz)
130,2 143,1  25,4  85 
Main transf. Primary winding (198V, 60Hz)
130,2 139,2  19,1  85 
 
 
 
 
 
 
*) Temperature rise limits for Singapore is 10K less
 
 
 
 
- Page 33 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
Monitored point: 
 
 
 
dT (K) at  
242V, 60Hz 
Limit dT (K) 
Main transformer core 
 
 
 
19,0  
85 
IC204 
heatsink 
   
25,6 
 
PWB near D912 
 
 
 
29,3  
70 
E-capacitor, C930 body 
 
 
 
24,7  
50 
IC91 
heatsink 
   
44,1 
 
PWB near IC91 
 
 
 
40,8  
70 
Busing 
   
9,8 
 
60 
Top enclosure above transformer 
 
 
 
11,1  
40 
Top enclosure above IC91  
 
 
 
14,6  
40 
Standby button (Non-metallic) 
 
 
 
2,0  
50 
 
 
 
 
 
 
 
         
 
Winding temperature rise 
measurements 
 
 
 
242V, 
60Hz 
— 
         
 
Ambient temperature t1 (
o
C) : 
   
24,4 
— 
         
 
Ambient temperature t2 (
o
C) : 
   
23,6 
— 
Temperature rise dT of winding: 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit dT (K)  Insulation 
class 
Main transf. Primary winding (242V, 60Hz)
130,2 141,3  22,9  85 
 
 
 
 
 
 
 
 
Page of 49