Harman Kardon TU 980 EMC - CB Certificate ▷ View online
- Page 34 of 38 -
Report
No.
97673
TRF No: IEC/EN 60065G
7.2
TABLE: softening temperature of thermoplastics
N/A
Temperature T of part
T – normal condi-
tions (
o
C)
T – fault condi-
tions (
o
C)
T softening
(
o
C)
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
> 100
2
Between parts separated by double or reinforced insulation
> 100
4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
1500Vac No
Between parts separated by double or reinforced insulation
3000Vac No
- Page 34 of 38 -
Report
No.
97673
TRF No: IEC/EN 60065G
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ......... :
253V or 198V
—
Ambient temperature (
o
C) ................................... :
23-26
o
C
—
Monitored point:
Under fault conditions specified below
Under fault conditions specified below
dT (K)
dT (K)
#)
*), D901 (A to C), S-c;
Normal operated. T
ransformer primary winding maximum
temperature 115,8K and thermal fuse opened after 41 min.
Dielectric strength test OK. No hazard.
Transf.
115,8
Transf.
150
**), D901 (A to C), S-c;
Normal operated. T
ransformer primary winding temperature stabilised.
Input current stabilised at 0,192A.
Dielectric strength test OK. No hazard.
Transf.
77,8
Transf.
150
*), C930, S-c;
FL display off immediately. T
ransformer primary winding temperature stabilised.
Input current stabilised at 0,186A. D904 damaged.
No hazard (Tested time: 1 hr 50 min)
No hazard (Tested time: 1 hr 50 min)
Transf.
102,8
Transf.
150
*), D912 (A to C), S-c;
Normal operated. T
ransformer primary winding maximum temperature
111,7K and thermal fuse opened after 24 min.
Dielectric strength test OK. No hazard.
Transf.
111,7
Transf.
150
*), C912, S-c;
Normal operated. T
ransformer primary winding temperature stabilised.
Input current stabilised at 0,118A. No hazard (Tested time: 1 hr 40 min)
Transf.
93,9
Transf.
150
*), D908 (A to C), S-c;
FL display off immediately.
Input current stabilised at 0,074A.
No component damaged. No hazard (Tested time: 30 min).
N/A N/A
*), C913, S-c;
FL display off immediately.
Input current stabilised at 0,082A.
No component damaged. No hazard (Tested time: 20 min)
N/A N/A
*), D221 (A to C), S-c;
FL display off immediately.
Input current stabilised at 0,106A.
T
ransformer primary winding temperature stabilised. R754 damaged.
No hazard (Tested time: 1 hr 30 min)
Transf.
88,8
Transf.
150
*), C746, S-c;
FL display off immediately.
Input current stabilised at 0,136A.
T
ransformer primary winding temperature stabilised. R754 damaged.
No hazard (Tested time: 1 hr 30 min)
Transf.
97,1
Transf.
150
*), D708 (A to C), S-c;
Normal operated.
Input current stabilised at 0,066A.
BAT1 body temperature stabilised and
no accumulation of flammable gases.
No component damaged. No hazard (Tested time: 8 hr)
BAT1 body
10,3
N/A
*) Tested voltage 253V **) Tested voltage 198V
#) Temperature rise limits for Singapore is 10K less
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded
- Page 35 of 38 -
Report
No.
97673
TRF No: IEC/EN 60065G
14
TABLE: list of critical components and materials
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference *)
Main
transformer
transformer
(T901)
Bobbin Mtl.
Thermal fuse
Seoul Electronics
Wintech Polymer
Anzen Dengu Co.
Wintech Polymer
Anzen Dengu Co.
CLT5M033ZE/
KLT5M033ZE
CN9030
KLT5M033ZE
CN9030
T5F
Class E
V-0, 155°C, PET
2A/250V, 136℃
V-0, 155°C, PET
2A/250V, 136℃
IEC60065
clause 14.3
UL94
IEC60691
clause 14.3
UL94
IEC60691
1.)
UL, E213445
VDE
Mains fuse
(F901)
alt.
Littelfuse
Orisel Co., Ltd.
Orisel Co., Ltd.
218 series
50T
50T
T1A L 250V
IEC60127
VDE
VDE
VDE
Mains plug/cord
(For CENELEC)
(For CENELEC)
KENIC
ELECTRIC.
ELECTRIC.
KE-21
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1 VDE
alt. KENIC
ELECTRIC.
KE-32
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1 VDE
alt. PHINO
ELECT.
PHP-205
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1 VDE
alt. VOLEX
(ASIA)
PTE.
M4206
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1 VDE
Mains plug / cord
(For Korea)
(For Korea)
See “Summary of testing”
Mains plug/cord
(For UK and
Singapore)
(For UK and
Singapore)
KENIC
ELECTRIC.
ELECTRIC.
KE-108
H03VVH2-F, or
H05VVH2-F
H03VVH2-F, or
H05VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
SS145
SS145
BSI
PSB
PSB
Mains plug/cord
(For UK)
(For UK)
PHINO ELECT.
PHP-307F
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt. VOLEX
(ASIA)
PTE.
MP5004A
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
VOLEX (ASIA) PT
E.
E.
MP5005
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt. WINBO
INDUSTRIES
MS 323N
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
LUEN TAI (IP’S)
KENIC ELECT.
KENIC ELECT.
9518
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
WELL SHIN ENTE
RPRISE.
RPRISE.
WS-012A
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
*) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition : 2002
- Page 36 of 38 -
Report
No.
97673
TRF No: IEC/EN 60065G
14
TABLE: list of critical components and materials-continued
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference *)
Mains connector
(CN91)
(CN91)
Yeonho Elect.
YW-396
YH-396
YH-396
5A/250V, V-0
IEC60065
1.), UL
X-capacitor
(C900)
alt.
alt.
alt.
(C900)
alt.
alt.
alt.
Okaya Electric Inc.
PILKOR Elect.
Yuchang Elect.
Carli Electronics.
Matsushita Elect.
PILKOR Elect.
Yuchang Elect.
Carli Electronics.
Matsushita Elect.
RE104
PCX2 335M
WBU1942
MPX
ECQUL
PCX2 335M
WBU1942
MPX
ECQUL
0.10uF/275 V,
X2
X2
IEC60384-14,
2
2
nd
ed.
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
Ni-MH battery
(BAT1)
(BAT1)
(non-rechargeable)
Guangzhou
Eastpower
Eastpower
30H3A3H
3.6V / 40mAh
(1.2V x 3 cells)
(1.2V x 3 cells)
-
1.)
Enclosure Mtl.
Main cabinet
Front base
alt.
Display window
alt.
Main cabinet
Front base
alt.
Display window
alt.
Various
Kumho Chemi.
Various
LG Chemical.
Various
Various
HFA-452
Various
HI-855M
Various
Sheet steel, 0.7mm
V-2, Min. 2.0 mm
V-2 or better
Min. 2,0mm thick
HB, Min. 2.4mm
HB or better,
Min. 2.4mm
-
UL94
UL94
UL94
UL94
1.)
UL, E65424
UL
UL, E67171
UL
PCB material
Various
Various
V-0, Min. 105
°C
UL796 UL
*) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition : 2002
Click on the first or last page to see other TU 980 service manuals if exist.