- Page 34 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
7.2 
TABLE: softening temperature of thermoplastics 
N/A 
Temperature T of part 
T – normal condi-
tions (
o
C) 
T – fault condi-
tions (
o
C) 
T softening 
(
o
C) 
 
 
 
 
 
 
 
10.3 
TABLE: insulation resistance measurements 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between mains poles (primary fuse disconnected) 
> 100
 
Between parts separated by double or reinforced insulation 
> 100
 
 
 
 
 
10.3 
TABLE: electric strength measurements 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Mains poles (primary fuse disconnected) 
1500Vac No 
Between parts separated by double or reinforced insulation 
3000Vac No 
 
 
 
 
 
- Page 34 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
11.2 
TABLE: summary of fault condition tests 
         
         
 
Voltage (V) 0,9 or 1,1 times rated voltage  ......... :
253V or 198V  
— 
         
 
Ambient temperature (
o
C)  ................................... :
23-26
 o
— 
Monitored point: 
Under fault conditions specified below 
dT (K)
 
dT (K) 
#) 
*), D901 (A to C), S-c;  
Normal operated. T
ransformer primary winding maximum  
temperature 115,8K and thermal fuse opened after 41 min. 
 
Dielectric strength test OK. No hazard. 
 
Transf. 
115,8 
Transf. 
150 
**), D901 (A to C), S-c;  
Normal operated. T
ransformer primary winding temperature stabilised. 
Input current stabilised at 0,192A. 
Dielectric strength test OK. No hazard.
 
Transf. 
77,8 
Transf. 
150 
*), C930, S-c;  
FL display off immediately. T
ransformer primary winding temperature stabilised. 
Input current stabilised at 0,186A. D904 damaged. 
No hazard (Tested time: 1 hr 50 min) 
Transf. 
102,8 
Transf. 
150 
*), D912 (A to C), S-c;  
Normal operated. T
ransformer primary winding maximum temperature  
111,7K and thermal fuse opened after 24 min. 
 
Dielectric strength test OK. No hazard. 
 
Transf. 
111,7 
Transf. 
150 
*), C912, S-c;  
Normal operated. T
ransformer primary winding temperature stabilised.  
Input current stabilised at 0,118A. No hazard (Tested time: 1 hr 40 min) 
Transf. 
93,9 
Transf. 
150 
*), D908 (A to C), S-c;  
FL display off immediately. 
Input current stabilised at 0,074A.  
No component damaged. No hazard (Tested time: 30 min). 
N/A N/A 
*), C913, S-c;  
FL display off immediately. 
Input current stabilised at 0,082A.  
No component damaged. No hazard (Tested time: 20 min) 
N/A N/A 
*), D221 (A to C), S-c;  
FL display off immediately. 
Input current stabilised at 0,106A.  
T
ransformer primary winding temperature stabilised. R754 damaged. 
No hazard (Tested time: 1 hr 30 min) 
Transf. 
88,8 
Transf. 
150 
*), C746, S-c;  
FL display off immediately. 
Input current stabilised at 0,136A.  
T
ransformer primary winding temperature stabilised. R754 damaged. 
No hazard (Tested time: 1 hr 30 min) 
Transf. 
97,1 
Transf. 
150 
*), D708 (A to C), S-c;  
Normal operated. 
Input current stabilised at 0,066A.  
BAT1 body temperature stabilised and 
no accumulation of flammable gases. 
No component damaged. No hazard (Tested time: 8 hr) 
BAT1 body 
10,3 
N/A 
 
 
 
*) Tested voltage 253V               **) Tested voltage 198V
 
#) Temperature rise limits for Singapore is 10K less 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded
 
 
 
- Page 35 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
14 
TABLE: list of critical components and materials 
Component 
Manufacturer/ 
trademark 
Type/model 
Value / rating 
Standard 
Approval/ 
Reference *) 
Main  
transformer 
(T901) 
 
Bobbin Mtl. 
 
Thermal fuse
 
Seoul Electronics 
 
 
Wintech Polymer 
 
Anzen Dengu Co.
 
CLT5M033ZE/ 
KLT5M033ZE 
 
CN9030
 
 
T5F 
Class E 
 
 
V-0, 155°C, PET
 
2A/250V, 136℃
 
IEC60065  
clause 14.3 
 
UL94 
 
IEC60691
 
1.) 
 
 
UL, E213445 
 
VDE 
Mains fuse 
(F901) 
alt. 
Littelfuse 
Orisel Co., Ltd. 
218 series 
50T 
T1A L 250V 
IEC60127 
VDE 
VDE 
Mains plug/cord 
(For CENELEC) 
KENIC 
ELECTRIC. 
KE-21 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1 VDE 
alt. KENIC 
ELECTRIC. 
KE-32 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1 VDE 
alt. PHINO 
ELECT. 
PHP-205 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1 VDE 
alt. VOLEX 
(ASIA) 
PTE. 
M4206 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1 VDE 
Mains plug / cord  
(For Korea) 
See “Summary of testing” 
Mains plug/cord 
(For UK and 
Singapore) 
KENIC 
ELECTRIC. 
KE-108 
H03VVH2-F, or
H05VVH2-F 
13A/250V 
6A/250V 
BS1363 
SS145 
BSI 
PSB 
Mains plug/cord 
(For UK) 
PHINO ELECT. 
PHP-307F 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
alt. VOLEX 
(ASIA) 
PTE. 
MP5004A 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
alt. 
VOLEX (ASIA) PT
E. 
MP5005 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
alt. WINBO 
INDUSTRIES 
MS 323N 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
alt. 
LUEN TAI (IP’S) 
KENIC ELECT. 
9518 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
alt. 
WELL SHIN ENTE
RPRISE. 
WS-012A 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
*) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition : 2002 
 
 
- Page 36 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
14 
TABLE: list of critical components and materials-continued 
Component 
Manufacturer/ 
trademark 
Type/model 
Value / rating 
Standard 
Approval/ 
Reference *) 
Mains connector 
(CN91) 
Yeonho Elect. 
YW-396 
YH-396 
5A/250V, V-0 
IEC60065 
1.), UL  
X-capacitor 
(C900) 
alt. 
alt. 
alt. 
Okaya Electric Inc. 
PILKOR Elect. 
Yuchang Elect. 
Carli Electronics. 
Matsushita Elect. 
RE104 
PCX2 335M 
WBU1942 
MPX 
ECQUL 
0.10uF/275 V, 
X2 
 
IEC60384-14, 
2
nd 
ed. 
VDE 
VDE 
VDE 
VDE 
VDE 
Ni-MH battery 
(BAT1) 
(non-rechargeable)
 
Guangzhou 
Eastpower 
30H3A3H 
3.6V / 40mAh 
(1.2V x 3 cells)
 
1.) 
Enclosure Mtl. 
Main cabinet 
 
Front base 
alt. 
 
 
Display window 
alt. 
 
Various 
 
Kumho Chemi. 
Various 
 
 
LG Chemical. 
Various 
 
Various 
 
HFA-452 
Various 
 
 
HI-855M 
Various 
 
Sheet steel, 0.7mm
 
V-2, Min. 2.0 mm 
V-2 or better 
Min. 2,0mm thick 
 
HB, Min. 2.4mm 
HB or better, 
Min. 2.4mm
 
 

 
UL94 
UL94 
 
 
UL94 
UL94 
 
1.) 
 
UL, E65424 
UL 
 
 
UL, E67171 
UL 
PCB material 
Various 
Various 
V-0, Min. 105
 
°C
 
UL796 UL 
 
 
 
 
 
 
*) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition : 2002 
Page of 49