DOWNLOAD Harman Kardon TU 980 Service Manual ↓ Size: 1.08 MB | Pages: 49 in PDF or view online for FREE

Model
TU 980
Pages
49
Size
1.08 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
tu-980.pdf
Date

Harman Kardon TU 980 EMC - CB Certificate ▷ View online

 
 
- Page 22 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
15 
TERMINALS 
 
15.1.1 
Mains plug, appliance inlet, interconnection couplers 
and mains socket-outlet meet the appropriate 
standard 
Approved mains plug  
provided, see list of critical  
components. 
 
Overloading of plugs or appliance inlets prevented if 
the apparatus has mains socket outlets 
No mains socket outlets 
N/A 
 
Overloading  of internal wiring prevented if the 
apparatus has mains socket outlets 
No mains socket outlets 
N/A 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
 
No risk of insertion in mains socket-outlets 
Standard connectors  
provided for Optical, RCA,  
mini jack and Antenna 
 
terminals. 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2 
No sockets indicated with  
the symbol 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets 
The equipment under test is 
not an adaptor. 
N/A 
15.2 
Provision for protective earthing 
N/A 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within equipment
Class II apparatus 
N/A 
 
Protective earth conductors correctly coloured 
 N/A 
 
Equipment with non-detachable mains cord provided 
with separate protective earth terminal near mains 
input 
 N/A 
 
Protective earth terminal resistant to corrosion 
 N/A 
 
Earth resistance  test: < 0,1 
Ω at 25 A  ................... : 
 N/A 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
 P 
15.3.1 
Adequate terminals for connection of permanent 
wiring 
Apparatus is not for  
permanent connection.
 
N/A 
15.3.2 
Reliable connection of non-detachable cords: 
 P 
 
Not soldered to conductors of a printed circuit board 
Not soldered
 
 
Adequate clearances and creepage distances 
between connections should a wire break away 
Wires are clamped two  
times to the contact  
terminal and provided with 
a two-pole connector
 
 
 
- Page 23 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
Wire secured by additional means to the conductor 
Adequately anchored.  
Tested with 5 N. 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar 
No screws and nuts  
clamping
 
N/A 
15.3.4 
Soldered conductors wrapped around terminal prior 
to soldering or held in place by additional means 
No soldered conductors. 
N/A 
 
Clamping of conductor and insulation if not soldered 
or held by screws 
Clamped insulators and 
conductors in connector.
 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment 
Terminals have adequate  
connection capacity
 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16 
 N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
No clamps. 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened 
 N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided 
 N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: contact 
pressure not transmitted by insulating material except 
ceramic 
No contact pressure  
transmitted through  
insulating
 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other 
The termination of the 
contacts are in adequate  
proximity to each other.
 
 
Terminals located and shielded: test with 8 mm 
strand 
Clamped contacts within  
connector
 
N/A 
15.4 
Devices forming a part of the mains plug 
 N/A 
15.4.1 
No undue strain on mains socket-outlets 
The apparatus is not a  
device forming a part of 
the mains plug.
 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs 
 N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c) 
 N/A 
 
 
 
- Page 24 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
16 
EXTERNAL FLEXIBLE CORDS 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic rubber 
cords  ....................................................................... : 
Sheathed PVC cord  
complying with IEC 60227
 
 
Non-detachable cords for Class I have green/yellow 
core for protective earth 
Class II apparatus
 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment 
The cord is min. 0,75mm², 
within the current rating
 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength 
 
No interconnecting cables  
comprising hazardous live  
conductors.
 
N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of IEC 60227-2)
Cord complying with 16.1
 
N/A 
16.4 
Flexible cords used for connection between equipment 
have adequate cross-sectional areas to avoid 
temperature rise under normal and fault conditions 
Cords have adequate 
cross-sectional areas to  
avoid temperature rise under 
normal and fault conditions. 
16.5 
Adequate strain relief on external flexible cords 
Cord clip wedged in the 
enclosure
 
 
Not possible to push cord back into equipment 
Checked by inspection
 
 
Strain relief device unlikely to damage flexible cord 
No sharp edges
 
 
For mains cords of Class I equipment, hazardous live 
conductors become taut before earth conductor 
Class II apparatus
 
N/A 
16.6 
Apertures for external flexible cord: no risk of damage 
to the cord during assembly or movement in use 
No sharp edges
 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet to 
IEC 60320-1 
The apparatus is not a  
transportable musical 
instrument and amplifier
 
N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord 
The apparatus is not a 
transportable musical 
instrument and amplifier
 
N/A 
 
 
- Page 25 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
17 ELECTRICAL 
CONNECTIONS AND MECHANICAL FIXINGS 
 
17.1 
Torque test to table 20: 
Screws fixing chassis to the 
main enclosure tested. 
 
- screws into metal: 5 times 
See attachment, Table to 
EN/IEC 60065 7
th
 edition 
 
- screws into non-metallic material: 10 times 
 N/A 
17.2 
Correct introduction into female threads in non-
metallic material 
No female threads in  
non-metallic materials 
N/A 
17.3 
Cover fixing screws: captive 
Captivity not necessary 
 
Non-captive fixing screws: no hazard when replaced 
by a screw whose length is 10 times its diameter 
Tested with screw with  
10 times diameter. 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A 
Loosening is sufficiently 
prevented 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a current 
> 0,2 A 
No contact pressure 
transmitted through insulating 
material. 
17.6 
Stranded conductors of flexible supply cords carrying 
a current > 0,2 A with screw terminals not 
consolidated by solder 
No screw terminals.
 
N/A 
17.7 
Cover fixing devices other than screws have adequate 
strength and their positioning is unambiguous 
No cover fixing devices  
other than screws 
N/A 
17.8 
Fixing devices for detachable legs or stands provided
No detachable provided 
N/A 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected 
Connections complies, 
checked by inspection 
 
Page of 49
Display