- Page 10 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
8.7 
This clause is void 
 — 
8.8 
Basic or supplementary insulation > 0,4 mm (mm)  : 
 
N/A 
 
Reinforced insulation > 0,4 mm (mm)  .................... : 
Transformer bobbin, 
thickness > 0,4 mm.  
Tested acc. to cl. 10.3 - OK. 
See list of critical components 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22) 
No thin sheet insulation
 
N/A 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 
 N/A 
 
Reinforced insulation, two layers each of which meet 
10.3 
 N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3 
 N/A 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts 
Double insulated
 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts 
Single insulation but 
safely anchored 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts. 
Double insulation between internal  hazardous live 
parts and conductors connected to accessible parts. 
Double insulated, tested  
according to 8.9 and 10.3. 
8.11 
Detaching of wires 
 P 
 
No undue reduction of creepages or clearance 
distances if wires become detached 
Primary wires are 
connected with  
multi-contact housing.
 
 Vibration 
test 
carried out  ........................................ : 
See 12.1.2 
N/A 
 
 
- Page 11 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
8.12 
This clause is void 
 — 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s) 
Adequately fastened. 
8.14 
Adequate fastening of covers (pull test 50 N for 10 s)
Tested O.K. 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges 
Wires safely anchored  
away from parts with high  
temperature. 
8.16 
Only special supply equipment can be used 
Not supplied by a special  
supply apparatus.
 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation 
No such winding wire. 
N/A 
8.18 
Endurance test as required by 8.17 
 N/A 
8.19 
Disconnection from the mains 
See below 
8.19.1 Disconnect 
device 
Mains plug is used as 
disconnect devices. 
 
All-pole switch or circuit breaker with >3mm contact 
separation 
No mains switch or circuit 
breaker 
N/A 
8.19.2 
Mains switch ON indication 
Indicator lamp or FL display 
lit-on
 
8.20 
Switch not fitted in the mains cord 
 P 
8.21 
Bridging components comply with clause 14 
No bridging components 
N/A 
8.22 
Non-separable thin sheet material 
No Non-separable thin  
sheet material 
N/A 
 
 
- Page 12 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No voltages exceeding 
1000V AC or 1500V DC. 
N/A 
9.1.1.1 
a) Open circuit voltages 
Mains input voltage >35 V, 
see below. 
— 
 
b) Touch current measured from terminal devices 
using the network in annex D  ................................. : 
See attachment, Table to  
EN/IEC 60065 7
th
 Edition 
 
c) Discharge not exceeding 45 μC 
No part or contact of a 
terminal with stored voltages
  
between 60V - 15 kV. 
N/A 
 
d) Energy of discharge not exceeding 350 mJ 
No part or contact of  
a terminal with stored  
voltages exceeding 15kV 
N/A 
9.1.1.2 
Test with test finger and test probe 
No access to hazardous  
live parts 
9.1.2 
No hazardous live shafts of knobs, handles or levers
No live shaft, handles or 
levers 
N/A 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin 
No ventilation holes in  
top enclosure 
N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032 
Does not reach hazardous 
live parts 
 
Terminal devices tested with 1 mm x 100 mm straight 
wire (1 N); test probe D of IEC 61032 
Does not reach hazardous 
live parts 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No preset controls 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  .................. : 
See below.
 
N/A 
 
If C is not greater than 0,1 μF no test needed 
C = 0,1 uF
 
N/A 
9.1.7 
a) Enclosure sufficiently resistant to external force 
 
 
 Test probe 11 of IEC 61032 for 10 s (50 N) 
Test with test finger  
result in no hazard 
 
 
- Page 13 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
b) Test hook of fig. 4 for 10 s (20 N) 
Test with test hook results 
in no hazard. 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  : 
Tested with 100N results  
in no damage. 
9.2 
No hazard after removing a cover by hand 
No cover removable by 
hand 
N/A 
 
10 INSULATION 
REQUIREMENTS 
 
10.1 
I
nsulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation  ................................................................. : 
> 100 M
Ω after surge test P 
10.2 
Humidity treatment 48 h or 120 h  ........................... : 
120 h (40
°C). 
No impairment 
10.3 
Insulation resistance and dielectric strength between 
mains teminals 
See appended table 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1) 
Class II apparatus.
 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II) 
See appended table 
 
11 FAULT 
CONDITIONS 
11.1 
No shock hazard under fault condition 
No electric shock hazard 
under fault conditions. 
11.2 
Heating under fault condition 
See appended table
. 
 
No hazard from softening solder 
No softening of solder. 
 
Flames extinguish within 10 seconds 
No flames. 
 
Soldered terminations not used  as protective 
mechanism 
No soldered terminations. 
11.2.1 
Measurement of temperature rises 
See appended table
 
11.2.2 
Temperature rise of accessible parts 
See appended table
 
Page of 49