Report
No.
97673
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N/A
Reinforced insulation > 0,4 mm (mm) .................... :
Transformer bobbin,
thickness > 0,4 mm.
Tested acc. to cl. 10.3 - OK.
thickness > 0,4 mm.
Tested acc. to cl. 10.3 - OK.
See list of critical components
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
No thin sheet insulation
N/A
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N/A
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
Double insulated
P
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
Single insulation but
safely anchored
safely anchored
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
Double insulated, tested
according to 8.9 and 10.3.
according to 8.9 and 10.3.
P
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Primary wires are
connected with
multi-contact housing.
connected with
multi-contact housing.
P
Vibration
test
carried out ........................................ :
See 12.1.2
N/A
- Page 11 of 38 -
Report
No.
97673
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
Adequately fastened.
P
8.14
Adequate fastening of covers (pull test 50 N for 10 s)
Tested O.K.
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
Wires safely anchored
away from parts with high
temperature.
away from parts with high
temperature.
P
8.16
Only special supply equipment can be used
Not supplied by a special
supply apparatus.
supply apparatus.
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
No such winding wire.
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
See below
P
8.19.1 Disconnect
device
Mains plug is used as
disconnect devices.
disconnect devices.
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
No mains switch or circuit
breaker
breaker
N/A
8.19.2
Mains switch ON indication
Indicator lamp or FL display
lit-on
lit-on
P
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
No bridging components
N/A
8.22
Non-separable thin sheet material
No Non-separable thin
sheet material
sheet material
N/A
- Page 12 of 38 -
Report
No.
97673
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltages exceeding
1000V AC or 1500V DC.
1000V AC or 1500V DC.
N/A
9.1.1.1
a) Open circuit voltages
Mains input voltage >35 V,
see below.
see below.
—
b) Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
Edition
P
c) Discharge not exceeding 45 μC
No part or contact of a
terminal with stored voltages
between 60V - 15 kV.
terminal with stored voltages
between 60V - 15 kV.
N/A
d) Energy of discharge not exceeding 350 mJ
No part or contact of
a terminal with stored
voltages exceeding 15kV
a terminal with stored
voltages exceeding 15kV
N/A
9.1.1.2
Test with test finger and test probe
No access to hazardous
live parts
live parts
P
9.1.2
No hazardous live shafts of knobs, handles or levers
No live shaft, handles or
levers
levers
N/A
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No ventilation holes in
top enclosure
top enclosure
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Does not reach hazardous
live parts
live parts
P
Terminal devices tested with 1 mm x 100 mm straight
wire (1 N); test probe D of IEC 61032
wire (1 N); test probe D of IEC 61032
Does not reach hazardous
live parts
live parts
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No preset controls
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s .................. :
of the mains plug; voltage (V) after 2 s .................. :
See below.
N/A
If C is not greater than 0,1 μF no test needed
C = 0,1 uF
N/A
9.1.7
a) Enclosure sufficiently resistant to external force
P
Test probe 11 of IEC 61032 for 10 s (50 N)
Test with test finger
result in no hazard
result in no hazard
P
- Page 13 of 38 -
Report
No.
97673
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
b) Test hook of fig. 4 for 10 s (20 N)
Test with test hook results
in no hazard.
in no hazard.
P
c) 30 mm diameter test tool for 5 s (100 or 250 N) :
Tested with 100N results
in no damage.
in no damage.
P
9.2
No hazard after removing a cover by hand
No cover removable by
hand
hand
N/A
10 INSULATION
REQUIREMENTS
10.1
I
nsulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
insulation ................................................................. :
> 100 M
Ω after surge test P
10.2
Humidity treatment 48 h or 120 h ........................... :
120 h (40
°C).
No impairment
P
10.3
Insulation resistance and dielectric strength between
mains teminals
mains teminals
See appended table
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
Class II apparatus.
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
See appended table
P
11 FAULT
CONDITIONS
P
11.1
No shock hazard under fault condition
No electric shock hazard
under fault conditions.
under fault conditions.
P
11.2
Heating under fault condition
See appended table
.
P
No hazard from softening solder
No softening of solder.
P
Flames extinguish within 10 seconds
No flames.
P
Soldered terminations not used as protective
mechanism
mechanism
No soldered terminations.
P
11.2.1
Measurement of temperature rises
See appended table
P
11.2.2
Temperature rise of accessible parts
See appended table
P