- Page 18 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Double or reinforced insulation  
between pri. and sec. windings 
according to clause 8.8. 
See attachment Tables to  
EN/IEC 60065 7
th 
edition. 
 
Coil formers and partition walls > 0,4 mm 
The bobbin fulfils the  
requirement of reinforced  
insulation; bobbin thickness  
> 0,4 mm. 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 14.3.4.2 
are met 
Transformers are evaluated 
with Class II construction 
N/A 
14.3.4.3 
Separating transformers with at least basic insulation
Windings of Class II  
construction used. 
N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Double or reinforced insulation 
between hazardous live  
windings and accessible  
conductive parts. 
 
Coil formers and partition walls > 0,4 mm 
The bobbin fulfils the  
requirement of reinforced  
insulation; bobbin thickness  
> 0,4 mm. 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Windings of Class II  
construction used. 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N/A 
14.4 
High voltage components 
No high-voltage components 
N/A 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved 
 N/A 
 
Component meets category V-1 of IEC 60707 
 N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 N/A 
 
 
- Page 19 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
14.5 Protective 
devices 
 P 
 
Protective devices used within their ratings 
Thermal link and fuse.
 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
Certified fuse used. 
See appended table, list of 
critical components. 
14.5.1.1 
a) Thermal cut-outs separately approved 
No thermal cut-outs. 
N/A 
 
b) Thermal cut-outs tested as part of the submission 
 N/A 
14.5.1.2 
a) Thermal links separately approved 
Thermal link in transformer 
is separately approved  
component, see list of critical 
components
 
 
b) Thermal links tested as part of the submission 
 N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
No thermal devices  
re-settable 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
Fuse is certified according 
to IEC60127.
 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... : 
Correct marking applied 
close to the fuse; 
F901, T1A L 250V 
14.5.2.3 
Not possible to connect fuses in parallel  ............... : 
No fuse holder so designed 
that fuse-links can be 
connected in parallel 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  ......... : 
No replacement of fuse  
possible by hand. 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
No PTC’s thermistors. 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
 N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked 
 N/A 
14.6 Switches 
No switches  
N/A 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3, and 
Make and break speed independent of speed of  
ctuation 
V-0 compliance with annex G, G.1.1 
 
N/A 
 
 
- Page 20 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
14.6.1 b) 
Tested in the apparatus: 
 N/A 
 
Switch controlling > 0.2A with open contact  voltage > 
35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1 
 N/A 
 
Switch controlling > 0.2A with open contact  voltage < 
35 V (peak)/24 V dc complying with 14.6.3 and V-0 in 
annex G, G.1.1 
 N/A 
 
Switch controlling < 0.2A with open contact  voltage > 
35 V (peak)/24 V dc complying with  14.6.4 and V-0 
in annex G, G.1.1 
 N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking  action 
independent of speed of actuation 
 N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and  m) not attaining excessive 
temperatures in use 
 N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
 N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1 
 
N/A 
 
Socket outlet current marking correct 
 N/A 
14.7 Safety 
interlocks 
No safety interlock 
N/A 
 
Safety interlocks to 2.8 of IEC 60950 
 N/A 
14.8 
Voltage setting devices 
and the like
 
No voltage setting devices 
N/A 
 
Voltage setting device not likely to be changed 
accidentally 
 N/A 
14.9 Motors 
No motors 
N/A 
14.9.1 
Endurance test on motors 
 N/A 
 
Motor start test 
 N/A 
 
Dielectric strength test 
 N/A 
14.9.2 
Not adversely affected by oil or grease etc. 
 N/A 
14.9.3 
Protection against moving parts 
 N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950, Annex B 
 N/A 
 
 
- Page 21 of 38 - 
 
 
 
 
 Report 
No. 
97673 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
14.10 Batteries 
Ni-MH button cell battery  
provided (BAT1
)
 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
No accumulation of  
flammable gases
 
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
Inside the apparatus, 
not replaceable by user
 
N/A 
14.10.3 
Recharging currents and times within manufacturers 
limits 
No rechargeable battery. 
N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
No lithium battery
 
N/A 
14.10.4 
Battery mould stress relief 
 N/A 
14.10.5 
Battery drop test 
 N/A 
14.11 Optocouplers 
No optocouplers 
N/A 
 
Optocouplers comply with Cl. 8 
 N/A 
 
Internal and external dimensions to 13.1. or 
alternatively 13.6 (jointed insulation) 
 N/A 
14.12 
Surge suppression varistors 
No surge suppression  
varistors
 
N/A 
 
Comply with IEC 61051-2 
 N/A 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus 
 N/A 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 
 
N/A 