Harman Kardon TU 980 EMC - CB Certificate ▷ View online
- Page 18 of 38 -
Report
No.
97673
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double or reinforced insulation
between pri. and sec. windings
according to clause 8.8.
See attachment Tables to
EN/IEC 60065 7
between pri. and sec. windings
according to clause 8.8.
See attachment Tables to
EN/IEC 60065 7
th
edition.
P
Coil formers and partition walls > 0,4 mm
The bobbin fulfils the
requirement of reinforced
insulation; bobbin thickness
> 0,4 mm.
requirement of reinforced
insulation; bobbin thickness
> 0,4 mm.
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of 14.3.4.2
are met
protective screening only if all 7 conditions of 14.3.4.2
are met
Transformers are evaluated
with Class II construction
with Class II construction
N/A
14.3.4.3
Separating transformers with at least basic insulation
Windings of Class II
construction used.
construction used.
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double or reinforced insulation
between hazardous live
windings and accessible
conductive parts.
between hazardous live
windings and accessible
conductive parts.
P
Coil formers and partition walls > 0,4 mm
The bobbin fulfils the
requirement of reinforced
insulation; bobbin thickness
> 0,4 mm.
requirement of reinforced
insulation; bobbin thickness
> 0,4 mm.
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Windings of Class II
construction used.
construction used.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No high-voltage components
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
- Page 19 of 38 -
Report
No.
97673
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.5 Protective
devices
P
Protective devices used within their ratings
Thermal link and fuse.
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Certified fuse used.
See appended table, list of
critical components.
See appended table, list of
critical components.
P
14.5.1.1
a) Thermal cut-outs separately approved
No thermal cut-outs.
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
Thermal link in transformer
is separately approved
component, see list of critical
components
is separately approved
component, see list of critical
components
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No thermal devices
re-settable
re-settable
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuse is certified according
to IEC60127.
to IEC60127.
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... :
Correct marking applied
close to the fuse;
F901, T1A L 250V
close to the fuse;
F901, T1A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ............... :
No fuse holder so designed
that fuse-links can be
connected in parallel
that fuse-links can be
connected in parallel
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
No replacement of fuse
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
No PTC’s thermistors.
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
N/A
14.6 Switches
No switches
N/A
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3, and
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3, and
Make and break speed independent of speed of
ctuation
ctuation
V-0 compliance with annex G, G.1.1
N/A
- Page 20 of 38 -
Report
No.
97673
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage >
35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage <
35 V (peak)/24 V dc complying with 14.6.3 and V-0 in
annex G, G.1.1
35 V (peak)/24 V dc complying with 14.6.3 and V-0 in
annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact voltage >
35 V (peak)/24 V dc complying with 14.6.4 and V-0
in annex G, G.1.1
35 V (peak)/24 V dc complying with 14.6.4 and V-0
in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and m) not attaining excessive
temperatures in use
1 subclause 16.2.2 d) and m) not attaining excessive
temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
N/A
Socket outlet current marking correct
N/A
14.7 Safety
interlocks
No safety interlock
N/A
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices
and the like
No voltage setting devices
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9 Motors
No motors
N/A
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
N/A
- Page 21 of 38 -
Report
No.
97673
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.10 Batteries
Ni-MH button cell battery
provided (BAT1
provided (BAT1
)
.
P
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
No accumulation of
flammable gases
flammable gases
P
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
Inside the apparatus,
not replaceable by user
not replaceable by user
N/A
14.10.3
Recharging currents and times within manufacturers
limits
limits
No rechargeable battery.
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
No lithium battery
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11 Optocouplers
No optocouplers
N/A
Optocouplers comply with Cl. 8
N/A
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
alternatively 13.6 (jointed insulation)
N/A
14.12
Surge suppression varistors
No surge suppression
varistors
varistors
N/A
Comply with IEC 61051-2
N/A
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus
except for earthed parts of permanently connected
apparatus
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N/A