Harman Kardon SOUNDSTICKS III (serv.man2) EMC - CB Certificate ▷ View online

IEC 60950-1 (ed.2)
 
 
- Page 2 of 3 - 
 
 
www.nemko.com
 
Report No.   158002 
 
 
 
 
Appliances rated 
 
3 kW or connected 
to fixed wiring 
Electric appliance 
 3 kW must be 
connected to fixed wiring. All 
connection to fixed wiring must be in 
accordance with Code of Practice 
CP5. 
The rated power is 
less than 3kW.  
N/A 
Detachable power 
cord set (consists 
of mains plug, 
mains cord and 
appliance 
connector 
Detachable power cord set must be 
listed in the test report critical 
component list. 
Class III equipment. 
N/A 
Circuit diagrams 
Circuit diagrams must be indicated 
with component’s values for 
products tested to IEC 60065 and 
IEC 60950. 
Complies. P 
10 
Circuit diagrams of 
electronic modules 
in electrical 
appliances 
Circuit diagrams of the electronic 
modules in the electrical appliances 
must be provided. 
Provided. P 
11 
Controlled goods 
likely to be treated 
as toy by children 
Controlled goods, having an 
enclosure, which is shaped and 
decorated so that it is likely to be 
treated as a toy by children, shall 
not be accepted for certification and 
registration. 
The equipment is 
not treated as toy 
by children. 
N/A 
Applicable to AC adaptor 
13 
3-pin AC adaptor 
Test report showing that the 3-pin 
complied with sub-clauses 12.1 & 
12.3 of SS 246 must be submitted. 
Class III equipment. 
N/A 
14 
2-pin 
AC 
adaptor 
The 2-pin (Appendix W) shall 
comply with IEC 83: 1975 (Standard 
C5, Version II) or EN 50075 
Class III equipment. 
N/A 
15 
Detachable power 
supply cord set not 
supplied by 
Registered 
Supplier 
Registered Supplier who is not 
supplying the detachable power 
supply cord set together with the AC 
Adaptor must provide written 
instruction to its customer on the 
type of approved detachable power 
cord set to use. 
Class III equipment. 
N/A 
Applicable to computer products 
16 
CD/DVD ROM 
(used in personal 
computer) 
Test certificate showing that 
CD/DVD ROM has complied with 
IEC 825 must be provided. 
The equipment 
does not consist of 
CD/DVD ROM. 
N/A 
17 
Modem Card (used 
in personal 
computer) 
Modem card incorporated in the 
personal computer must be tested 
at set level (sub-clauses 5.1 & 6 of 
The equipment 
does not consist of 
Modem Card. 
N/A 
IEC 60950-1 (ed.2)
 
 
- Page 3 of 3 - 
 
 
www.nemko.com
 
Report No.   158002 
 
 
 
IEC 60950) or at component level. 
Applicable to plasma/LCD display monitor 
35 
Plasma/LCD 
display monitor 
with TV tuner 
Plasma/LCD display monitor tested 
to IEC 60950 would require 
additional test to clauses 9 (related 
to antenna only), 10.1, 10.2, 10.3 
and 12.5 of IEC 60065.  
No TV tuner 
provided. 
N/A 
 
 
IEC 60950-1 (ed.2)
 
 
- Page 1 of 
7
 - 
 
 
www.nemko.com 
Report No.   158002 
 
 
IEC 60950-1:2005 
Clause 
Requirements – Test 
Result – Remark 
Verdict
USA - Differences to IEC 60950-1:2005, Second Edition 
1.1 
Equipment able to be installed in accordance 
with the National Electrical Code ANSI/NFPA 70 
Class III equipment. 
 
1.1.1 
Equipment able to be installed in accordance 
with ANSI/NFPA 75 and NEC Art. 645 unless 
intended for use outside of computer room and 
provided with such instructions. 
Class III equipment. 
N/A 
1.1.2 
Equipment in wire-line communication facilities 
serving high-voltage electric power stations 
operating at greater than 1kV are excluded. 
Class III equipment. 
N/A 
1.1.2 
Equipment intended for outdoor use 
Not used outdoor 
N/A 
1.4.14 
For Pluggable Equipment Type A, the protection 
in the installation is assumed to be 20 A. 
Class III equipment. 
N/A 
1.5.1 
All IEC standards for components identified in 
Annex P.1 replaced by the relevant requirements 
of UL component standards in Annex P.1. 
See table 1.5.1 in main test 
report. 
1.5.1 
All IEC standards for components identified in 
Annex P.2 alternatively satisfied by the relevant 
requirements of UL component standards 
See table 1.5.1 in main test 
report. 
1.5.5 
Interconnecting cables acceptable for the 
application regarding voltage, current, 
temperature, flammability, mechanical 
serviceability and the like. 
Suitable interconnecting cable 
used. 
1.5.5 
For other than limited power and TNV circuits, 
the type of output circuit identified for output 
connector. 
No TNV circuit 
N/A 
1.5.5 
External cable assemblies that exceed 3.05 m in 
length to be types specified in the NEC 
Class III equipment. 
N/A 
1.5.5 
Detachable external interconnecting cables 3.05 
m or less in length and provided with equipment 
marked to identify the responsible organization 
and the designation for the cable 
Class III equipment. 
N/A 
1.5.5 
Building wiring and cable for use in ducts, 
plenums and other air handling space subject to 
special requirements and excluded from scope. 
Considered. 
 
1.5.5 
Telephone line and extension cords and the like 
comply with UL 1863 
No TNV circuit 
N/A 
1.6.1.2 Equipment 
intended 
for connection to a d.c. 
power (mains) distribution system subjected to 
special circuit classification requirements (e.g., 
TNV-2) 
Class III equipment. 
N/A 
1.6.1.2 
Earthing of d.c. powered equipment provided 
Class III equipment. 
N/A 
1.7 
Lamp replacement information indicated on 
lampholder in operator access area 
No lamp provided. 
N/A 
1.7.1 
Special marking format for equipment intended 
for use on a supply system with an earthed 
neutral and more than one phase conductor 
Class III equipment. 
N/A 
1.7.1 
Equipment voltage rating not higher than rating of 
the plug except under special conditions 
No plug provided. 
 
IEC 60950-1 (ed.2)
 
 
- Page 2 of 7 - 
 
 
www.nemko.com
 
Report No.   158002 
 
 
 
1.7.6 
Fuse replacement marking for operator 
accessible fuses 
No operator accessible fuses. 
N/A 
1.7.7 
Identification of terminal connection of the 
equipment earthing conductor 
No such terminal connection. 
 
1.7.7 
Connectors and field wiring terminals for external 
Class 2 or Class 3 circuits provided with marking 
indicating minimum Class of wiring to be used. 
No such terminal used. 
N/A 
1.7.7 
Marking located adjacent to terminals and visible 
during wiring 
No such terminal used. 
N/A 
2.1.1.1 
Bare TNV conductive parts protected by a cover 
are exempt if instructions include directions for 
disconnection of TNV prior to removal of the 
cover 
No TNV circuity. 
N/A 
2.3.1.b Other 
telecommunication signaling systems than 
described in 2.3.1(b) are subject to M.4. 
No TNV circuity. 
N/A 
2.3.1.b 
For TNV-2 and TNV-3 circuits with other than 
ringing signals and with voltages exceeding 42.4 
Vp or 60 V d.c., the max. current limit through a 
resistor ≥ 2000 Ohm with loads disconnected is 
7.1 mA peak or 30 mA d.c. under normal 
conditions 
No TNV circuity. 
N/A 
2.3.1.b 
Limits for measurements across 5000 Ohm 
resistor in the event of a single fault are replaced 
after 200 ms with the limits of M.3.1.4. 
No TNV circuity. 
N/A 
2.3.2.1 
For a single fault, the limits of 2.2.3 apply to 
SELV circuits and accessible conductive parts. 
No TNV circuity.  
N/A 
2.3.2.4 
Enamel coating on signal transformer winding 
wire allowed as an alternative to Basic insulation 
in specific telecommunication applications if 
subject to special construction requirements and 
testing 
No TNV circuity.  
N/A 
2.5 
Overcurrent protection device required for Class 
2 and Class 3 limiting according to the NEC, or 
for a Limited Power Source, not interchangeable 
with devices of higher ratings if operator 
replaceable 
No such device.  
N/A 
2.6 
Equipment having receptacles for output a.c. 
power connectors generated from an internal 
separately derived source have the earthed 
(grounded) circuit conductor suitably bonded to 
earth. 
Class III equipment.  
N/A 
2.6.3.3 
For Pluggable Equipment Type A, if a) b) or c) 
are not applicable, the current rating of the circuit 
is taken as 20 A 
Class III equipment. 
 
2.6.3.4 
Capacity of connection between earthing terminal 
and parts required to be earthed subject to 
special conditions based on the current rating of 
the circuit. 
Class III equipment. 
 
2.6.4.1 
Field wiring terminals for earthing conductors 
suitable for wire sizes (gauge) used in US  
Class III equipment. 
N/A 
2.7.1 
Data for selection of special external branch 
circuit overcurrent devices marked on the 
equipment 
Class III equipment. 
N/A 