Document
EMC - CB Certificate
Brand
Device
Audio
File
soundsticks-iii-sm2.pdf
Date

Harman Kardon SOUNDSTICKS III (serv.man2) EMC - CB Certificate ▷ View online

IEC 60950-1 (ed.2)
 
 
- Page 5 of 6 - 
 
 
www.nemko.com
 
Report No.   158002 
 
 
 
 
Projected area of opening  ......................................
Minor dimension of projected area  ........................
  
 
4.2.11 
For equipment intended for mounting on racks 
and provided with slide/rails allowing the 
equipment to slide away from the rack for 
installation, service and maintenance, additional 
construction, performance and marking 
requirements are applicable to determine the 
adequacy of the slide/rails. 
Not to be mounted on rack. 
N/A 
4.3.2 
Equipment with handles is required to comply 
with special loading tests. 
The equipment has no handles. 
N/A 
5.1.8.3 
Equipment intended to receive 
telecommunication ringing signals is required to 
comply with a special touch current 
measurement tests.  
No TNV circuitry. 
N/A 
 Ringing 
ports 
provided:  ..........................................
Simulation provided to:  ..........................................
Measured total touch current :  ...............................
 
 N/A 
5.3.7 
Internal (e.g., card cage) SELV circuit connectors 
and printed wiring board connectors that are 
accessible to the operator and that deliver power 
are to be overloaded. 
During abnormal operating testing, if a circuit is 
interrupted by the opening of a component, the 
test shall be repeated twice (three tests total) 
using new components as necessary. 
See main test report table 5.3  
6.4 
Equipment intended for connection to 
telecommunication network outside plant cable is 
required to be protected against overvoltage from 
power line crosses in accordance with 6.4 and 
Annex NAC. 
No TNV circuitry. 
N/A 
M.2 
Continuous ringing signals up to 16 mA only are 
permitted if the equipment is subjected to special 
installation and performance restrictions. 
No TNV circuitry. 
N/A 
Annex 
NAD 
Equipment connected to a telecommunication 
and cable distribution networks and supplied with 
an earphone intended to be held against, or in 
the ear is required to comply with special 
acoustic pressure requirements. 
No TNV circuitry. 
N/A 
Annex 
NAF 
Document (paper) shredders likely to be used in 
a home or home office (Pluggable Equipment 
Type A plug configuration) are required to comply 
with additional requirements, including 
markings/instructions, protection against 
inadvertent reactivation of a safety interlock, 
disconnection from the mains supply (via 
provision of an isolating switch), and protection 
against operator access (accessibility determined 
via new accessibility probe & probe/wedge).  
This equipment is not Document 
shredding machines. 
N/A 
 
Annex NAF 
Household/home office Document shredders
 
IEC 60950-1 (ed.2)
 
 
- Page 6 of 6 - 
 
 
www.nemko.com
 
Report No.   158002 
 
 
 
NAF1.7 
Markings and Instructions 
 
 
NAF 
1.7.15 
Symbols alerting the user to the following 
considerations are provided adjacent to the 
document feed opening.  These symbols are 
explained in the instructions: 
This equipment is not Document 
shredding machines. 
N/A 
 
Product is not intended for use by children 
(product is not a toy)  ..............................................
 N/A 
 
Avoid touching the document feed opening with 
hands  .....................................................................
 N/A 
 
Avoid clothing touching the document feed 
opening ...................................................................
 N/A 
 
Keep aerosol products away (applicable for 
product with brush motor only)  ..............................
 N/A 
 
The 
 (ISO 7000-0434) symbol to alert user to 
important operating, maintenance and/or 
servicing instructions and the explanation of 
above symbols 
 N/A 
 
Marking is permanent, comprehensible and 
easily discernible on the equipment. 
 N/A 
NAF 
2.8.3 
Safety interlock can not be activated by 
articulated accessibility probe (NAF.1) 
 N/A 
 
 
 
 
NAF 3.4  Isolation switch complying with 3.4.2 is provided 
to disconnect power to hazardous moving parts 
This equipment is not Document 
shredding machines. 
N/A 
 
On/off marking is provided for two position switch .  
N/A 
 
Off marking for multi-position switch  ......................  
N/A 
 
 
 
 
NAF 4.4  Protection against hazardous moving parts 
This equipment is not Document 
shredding machines. 
 
 
Accessibility probe (Fig NAF.1) is inserted 
without force into each opening and did not 
contact hazardous moving parts 
 N/A 
 
Operator accessible guards are removed and 
Accessibility wedge is inserted into each opening 
according without contacting mechanical 
hazards: 
 N/A 
 
Strip-cut (45N):  .......................................................  N/A 
 Cross-cut 
(90N) ......................................................  N/A 
IEC 60950-1 (ed.2)
 
 
- Page 1 of 1 - 
 
 
www.nemko.com 
Report No.   158002 
 
 
ATTACHMENT: KOREAN DIFFERENCES 
Test results according to CB BULLETIN 
 
Clause 
Requirements – Test 
Result – Remark 
Verdict
1.5.101 Addition 
Plugs for the connection of the apparatus to the 
supply mains shall comply with the Korean 
requirement (KSC 8305 and 8305). 
Class III equipment. 
N/A 
7 Addition 
EMC 
The apparatus shall comply with the relevant 
CISPR standards. 
Compliance with EMC must be 
considered when marketed in 
Korea. 
 
IEC 60950-1 (ed.2)
 
 
- Page 1 of 3 - 
 
 
www.nemko.com 
Report No.   158002 
 
 
ATTACHMENT: SINGAPORE DIFFERENCES 
to IEC 60950-1 (ed.1) 
 
 
No 
Item  
Requirement 
Result - Remark 
Verdict
The following is the national differences in accordance with safety authority website 
www.safety.org.sg/  , ref. Singapore Consumer Protection (Safety Requirements) - Information 
booklet - chapter 7 (page 21 - 24). Based on information by Singapore NCB – PSB Corp.
 
7 SAFETY 
AUTHORITY’S 
REQUIREMENTS
 
The Safety Authority monitors the safety of the controlled goods sold in Singapore by 
investigating all complaints, incidents and accidents reported to the authority. Experiences 
gained are translated into the Safety Authority’s Requirements. These requirements are to be 
fulfilled in addition to the applicable safety standards.
 
Applicable to all electrical products 
All appliances 
All appliances must be tested to 230 
VAC. 
Class III equipment. 
N/A 
Voltage selector 
(voltage mis-match 
test) 
Appliance fitted with voltage selector 
shall be tested as follows: 
Connect appliance to 230 VAC 
mains with voltage selector switch to 
settings not suitable for operation at 
230 VAC. 
Class III equipment. 
N/A 
Tropical condition 
test 
All appliances (with tropical test 
requirements in applicable 
Standards) shall comply with the 
tropical condition test as stated in 
the relevant IEC Standards. 
No applicable 
N/A 
Class I appliances  
(3-pin mains plug) 
All Class I appliances must be fitted 
with 3-pin mains plugs complied 
with SS 145/SS 472 that are 
registered with the Safety Authority.  
Class III equipment. 
N/A 
Class II appliances 
(mains plug) 
a) All Class II appliances must be 
fitted with 2-pin mains plug 
(Appendix W) complied with IEC 83: 
1975 (Standard C5, Version II) or 
EN 50075: 1991.   
b) Class II appliances that are fitted 
with 3-pin mains plugs must use 
plugs that are complied with SS 145 
and registered with the Safety 
Authority. 
Class III equipment. 