IEC 60950-1 (ed.2)
- Page 7 of 7 -
www.nemko.com
Report No. 158002
M.2
Continuous ringing signals evaluated to Method
A subjected to special accessibility
considerations.
A subjected to special accessibility
considerations.
No TNV circuit.
N/A
M.4
Special requirements for message waiting and
similar telecommunications signals.
similar telecommunications signals.
No TNV circuit.
N/A
NAC
Equipment for use with a generic secondary
protector marked with suitable instructions.
protector marked with suitable instructions.
No TNV circuit.
N/A
NAC
Equipment marked with suitable instructions if for
use with a specific primary or secondary
protector
use with a specific primary or secondary
protector
No TNV circuit.
N/A
NAD
Acoustic pressure from an ear piece for short and
long duration disturbances
long duration disturbances
No TNV circuit.
N/A
NAD
Equipment connected to a telecommunication
and cable distribution networks and supplied with
an earphone intended to be held against, or in
the ear is required to comply with special
acoustic pressure requirements
and cable distribution networks and supplied with
an earphone intended to be held against, or in
the ear is required to comply with special
acoustic pressure requirements
No TNV circuit.
N/A
NAF
Household/Home Office Document Shredders
N/A
NAF.1.7 Markings and instructions alert the user to key
safety considerations related to use of shredders,
including not intended to be used by children,
avoid touching document feed opening, avoid
clothes and hair entanglement, and avoid aerosol
products.
including not intended to be used by children,
avoid touching document feed opening, avoid
clothes and hair entanglement, and avoid aerosol
products.
This equipment is not Document
shredding machines.
shredding machines.
N/A
NAF.2.8.
3
3
Safety interlock cannot be inadvertently activated
by the articulated accessibility probe
by the articulated accessibility probe
This equipment is not Document
shredding machines.
shredding machines.
N/A
NAF.3.4 Provided with an isolating switch complying with
3.4.2, including 3 mm contact gap, with
appropriate markings associated with the switch.
appropriate markings associated with the switch.
This equipment is not Document
shredding machines.
shredding machines.
N/A
NAF.4.4 Hazardous moving parts are not accessible, as
determined using the articulated accessibility
probe and the accessibility probe/wedge
probe and the accessibility probe/wedge
This equipment is not Document
shredding machines.
shredding machines.
N/A
IEC 60950 (3rd)
- Page 1 of 1 -
www.nemko.com
Report No. 158002
ATTACHMENT: CHINESE DIFFERENCES
Test results according to CB BULLETIN
Clause
Requirement - Test
Result - Remark
Verdict
1.4.5 Supply
tolerance:
Item 1.4.5 of IEC 60950 stipulates the
tolerance of rated voltage is +6% and –10%,
while GB4943-2001 makes a specification of
tolerance of +10% and –10%.
tolerance of rated voltage is +6% and –10%,
while GB4943-2001 makes a specification of
tolerance of +10% and –10%.
Class III equipment
N/A
1.7.1
Power rating marking:
Item 1.7.1 of IEC 60950 does not specify
concrete figures of markings for supply voltage
and frequency, instead, descriprions are give
by examples. But the examples do not include
Chinas`s mains voltage.
GB4943-2001 stiplulates that:
- A single rated voltage shall be expressed as
220V
- When a rated volrage range is given, the
range shall cover 220V
- When a variety of rated voltages or rated
voltage ranges are given, one of them shall be
220V, and shall be set as 220V when
dispatched from the factory
- Rated frequency or rated frequency range
shall be 50Hz or include 50Hz
- If a unit is not provided with a means of direct
connection to the a.c. mains supply, it need not
be marked with any electrical rating
Item 1.7.1 of IEC 60950 does not specify
concrete figures of markings for supply voltage
and frequency, instead, descriprions are give
by examples. But the examples do not include
Chinas`s mains voltage.
GB4943-2001 stiplulates that:
- A single rated voltage shall be expressed as
220V
- When a rated volrage range is given, the
range shall cover 220V
- When a variety of rated voltages or rated
voltage ranges are given, one of them shall be
220V, and shall be set as 220V when
dispatched from the factory
- Rated frequency or rated frequency range
shall be 50Hz or include 50Hz
- If a unit is not provided with a means of direct
connection to the a.c. mains supply, it need not
be marked with any electrical rating
Class III equipment
N/A
1.7.12
Plate and warning marking in Chinese:
Item 1.7.12 of GB4943-2001 stipulates;
instructions and equipment markings related to
safety shall be in simplified Chinese
Item 1.7.12 of GB4943-2001 stipulates;
instructions and equipment markings related to
safety shall be in simplified Chinese
Must be check when marketed
in Chinese.
in Chinese.
N/A
3.2.1
Power supply plug:
According to China`s particular standards for
power supply plug, it is added in article 3.2.1 of
GB4943-2001 that plug connecting equipment
with a.c. mains supply shall be in accordance
with requirements of GB1002
According to China`s particular standards for
power supply plug, it is added in article 3.2.1 of
GB4943-2001 that plug connecting equipment
with a.c. mains supply shall be in accordance
with requirements of GB1002
Class III equipment
N/A
IEC 60950 (3rd)
- Page 1 of 6 -
www.nemko.com
Report No. 158002
Japan Differences to IEC 60950 Third Edition
Clause
Requirement - Test
Result - Remark
Verdict
1.2
Addition:
Add the following terms.
Equipment, Class 0I
1.2.4.101
Material, VTM
1.2.12.101
Considered.
—
1.2.4.101
Addition:
CLASS 0I EQUIPMENT: Equipment where protection
against electric shock is achieved by:
against electric shock is achieved by:
a) using BASIC INSULATION, and
b) providing a means of connecting to the protective
earthing conductor in the building wiring those
conductive parts that are otherwise capable of
assuming HAZARDOUS VOLTAGES if the BASIC
INSULATION fails, and
earthing conductor in the building wiring those
conductive parts that are otherwise capable of
assuming HAZARDOUS VOLTAGES if the BASIC
INSULATION fails, and
c) using a supply cord without earthing conductor and
a plug without earthing wire although the equipment
has externally an earth terminal or a lead wire for
earthing.
a plug without earthing wire although the equipment
has externally an earth terminal or a lead wire for
earthing.
Equipment provided with a cord set having a two-pin
type plug with a lead wire for earthing is also regarded
as Class 0I.
type plug with a lead wire for earthing is also regarded
as Class 0I.
NOTE – Class 0I equipment may have a part
constructed with Double Insulation or Reinforced
Insulation as well as an operating part as SELV circuit.
constructed with Double Insulation or Reinforced
Insulation as well as an operating part as SELV circuit.
Class III equipment.
N/A
1.2.12.1
Replacement:
FLAMMABILITY CLASSIFICATION OF MATERIALS:
The recognition of the burning behaviour of materials
and their ability to extinguish if ignited. Materials are
classified as in 1.2.12.2 to 1.2.12.9, and 1.2.12.101
when tested in accordance with annex A.
The recognition of the burning behaviour of materials
and their ability to extinguish if ignited. Materials are
classified as in 1.2.12.2 to 1.2.12.9, and 1.2.12.101
when tested in accordance with annex A.
NOTE 1 - When applying the requirements in this
standard, HF-1 CLASS FOAMED MATERIALS are
regarded as better than those of CLASS HF-2, and
HF-2 better than HBF.
standard, HF-1 CLASS FOAMED MATERIALS are
regarded as better than those of CLASS HF-2, and
HF-2 better than HBF.
NOTE 2 - Similarly, other MATERIALS, including rigid
(engineering structural) foam of CLASSES 5V or V-0
are regarded as better than those of CLASS V-1, V-1
better than V-2, and V-2 better than HB.
(engineering structural) foam of CLASSES 5V or V-0
are regarded as better than those of CLASS V-1, V-1
better than V-2, and V-2 better than HB.
NOTE 3 - Similarly, for thin MATERIALS, VTM-0 Class
materials are regarded as better than those of VTM-1
Class, and VTM-1 better than VTM-2.
materials are regarded as better than those of VTM-1
Class, and VTM-1 better than VTM-2.
Considered. P
IEC 60950 (3rd)
- Page 2 of 6 -
www.nemko.com
Report No. 158002
1.2.12.101
Addition:
VTM CLASS MATERIAL: Thin MATERIALS fulfil the
specified conditions during the test of clause A.101
applied for materials that the test and evaluation of
clauses A.6 to A.10 is difficult to enforce. Materials are
classified to three classifications as VTM-0, VTM-1 and
VTM-2 according to the conditions after the removal of
the test flame.
specified conditions during the test of clause A.101
applied for materials that the test and evaluation of
clauses A.6 to A.10 is difficult to enforce. Materials are
classified to three classifications as VTM-0, VTM-1 and
VTM-2 according to the conditions after the removal of
the test flame.
Considered. P
1.7.101
Addition:
Marking for CLASS 0I EQUIPMENT
For CLASS 0I EQUIPMENT, the following instruction
shall be indicated on the visible place of the mains plug
or the main body:
shall be indicated on the visible place of the mains plug
or the main body:
“Provide an earthing connection”
Moreover, for CLASS 0I EQUIPMENT, the following
instruction shall be indicated on the visible place of the
main body or written in the operating instructions:
instruction shall be indicated on the visible place of the
main body or written in the operating instructions:
“Provide an earthing connection before the mains plug
is connected to the mains. And, when disconnecting
the earthing connection, be sure to disconnect after
pulling out the mains plug from the mains.”
is connected to the mains. And, when disconnecting
the earthing connection, be sure to disconnect after
pulling out the mains plug from the mains.”
Class lII equipment.
N/A
2.1.1.1
Replacement:
Replace “IEC 60083” to “IEC 60083 or JIS C 8303” in
2.1.1.1 b).
Replace “IEC 60083” to “IEC 60083 or JIS C 8303” in
2.1.1.1 b).
Class III equipment
N/A
2.6.3.1
Addition:
Add the following after 1st paragraph.
This also applies to the conductor of lead wire for
protective earthing of CLASS 0I EQUIPMENT.
protective earthing of CLASS 0I EQUIPMENT.
Class III equipment
N/A
2.6.4.1
Replace the second sentence in the first paragraph of
this Sub-Clause by:
For CLASS I EQUIPMENT with a DETACHABLE
POWER SUPPLY CORD, the earthing terminal in the
appliance inlet is regarded as the main protective
earthing terminal.
this Sub-Clause by:
For CLASS I EQUIPMENT with a DETACHABLE
POWER SUPPLY CORD, the earthing terminal in the
appliance inlet is regarded as the main protective
earthing terminal.
Class III equipment
N/A
2.6.5.4
Replace the first sentence of this Sub-Clause by:
Protective earthing connections of CLASS I
EQUIPMENT shall make earlier and break later than
the supply connections in each of the following:
Protective earthing connections of CLASS I
EQUIPMENT shall make earlier and break later than
the supply connections in each of the following:
Class III equipment
N/A